Orion XS firmware 1.15: reverse charging of the starter battery, step by step
Firmware 1.15 gives the Victron Orion XS its emergency reverse charge: the energy flows the other way, from the house battery to the starter battery. Deeck, an independent iPhone app, builds on it: with Deeck 1.0.2, starter battery charging is in Deeck, and this guide takes you from the Orion update to the first charge.
Five steps: update the Orion, set it up as a charger, connect it in Deeck, start the first emergency charge, then the Deeck Plus functions. At the end, what to check if the charge doesn’t start. What Deeck does with it, free and with Deeck Plus: charge the starter battery with the Orion XS.
Before you start
- An Orion XS and VictronConnect, Victron’s app, on the iPhone.
- Deeck updated to the latest version: you need Deeck 1.0.2 or later.
- A reading of the house battery’s charge in Deeck: a battery monitor or a BMS read over Bluetooth, a GX or VRM. The Orion on its own isn’t enough: without this reading the charge doesn’t start, the emergency charge included. Below 50 % the charge doesn’t start; with Deeck Plus you set the threshold from 20 to 95 %.
- The Orion read over Bluetooth, from the iPhone or from Deeck Bridge on your Cerbo GX or on a Raspberry Pi with Venus OS, within Bluetooth range of the Orion. With the Bridge: Deeck Bridge updated to the latest version.
- The Orion’s Bluetooth PIN (000000 if you’ve never changed it).
1. Update the Orion XS to firmware 1.15
- 1
Update VictronConnect on the iPhone: Victron lists VictronConnect 6.43 or later for the emergency reverse charge.
- 2
In VictronConnect, connect to the Orion XS with its PIN, open the settings with the cog at the top right, tap the three dots at the top right and open Product info.
- 3
The Firmware line shows the installed version and lets you update it. Install the update and check that it reads 1.15 or a later version.
You need firmware 1.15 or later: that’s the version that gave the Orion XS its emergency reverse charge.
2. Set it up as a charger
- 1
In the Orion’s settings in VictronConnect, set Function to Charger, not power supply.
- 2
Keep Engine shutdown detection or Input voltage lock-out active: at least one of the two. This is Victron’s requirement for the reverse charge.
Victron’s manual notes that engine shutdown detection is on by default in charger mode, and lists the start conditions of the reverse charge (Orion XS manual, Emergency reverse charge). The values for each alternator type: Orion XS LiFePO4 settings.
3. Connect the Orion in Deeck
- 1
Update Deeck to the latest version from the App Store: starter battery charging is there from Deeck 1.0.2.
- 2
If the Orion isn’t in Deeck yet, add it: in “Devices” tap “+”, tap the Orion and type its PIN.
With Deeck Bridge on board, on your Cerbo GX or on a Raspberry Pi with Venus OS within Bluetooth range of the Orion, update Deeck Bridge to the latest version too. The emergency charge through the Bridge works with the iPhone on the same network as the Bridge; from afar you need Deeck Plus.
4. The first emergency charge
- 1
Engine off: with the engine running, the charge doesn’t start. Open “Starter battery” in Deeck: you’ll find it on the Orion XS card in “Devices” and on the “Deck” tab, in the engine tile.
- 2
Tap “Emergency charge” and confirm: Deeck reminds you it’s a quick boost from the house battery that stops on its own. The first time, Deeck also asks which starter battery you have: lead-acid, AGM, gel or lithium. Pick yours: if you answer that you don’t know, the charge doesn’t start.
- 3
It’s one Orion cycle of about 15 minutes, free for everyone, with no choice of curve or voltage: from the iPhone alone over Bluetooth, or through Deeck Bridge with the iPhone on the same network as the Bridge.
- 4
Follow it on the “Charging now” card: voltage and current chart, elapsed time, phase, Ah and Orion temperature. From the iPhone alone, the charge stops by itself when the battery is charged or after the maximum time.
- 5
When it’s done you find it in the charge history, with type, duration, Ah, voltage, outcome and its own chart.
5. With Deeck Plus: full charge, automatic care, alerts
- Full charge, with “Charge now”: until it’s full. With Deeck Bridge you start it from afar too; without the Bridge it runs from your iPhone, including one left on board. It works with the app open in the foreground and the iPhone near the Orion: if the app goes to the background, the charge stops within 15 minutes.
- “Battery type”: in the charge settings, pick the curve for your starter battery: “Lead-acid, calcium or EFB”, “AGM”, “Gel”, “Lithium (LiFePO4)” or “Gentle charge”.
- House battery threshold: in the “Starter battery” settings you set it from 20 to 95 %; on the free version it’s 50 %.
- “Top it up when you open the app”: without the Bridge, off by default. If the starter battery is below the threshold, a short charge starts as soon as you open Deeck nearby; it works while the app is open.
- Automatic care: with Deeck Bridge, off by default. Deeck keeps the starter battery charged by itself.
- Extra sun: with Deeck Bridge, off by default. When the house battery is nearly full and the sun is out, it charges the starter battery.
- The alerts when it’s ready, when it gets weak and when it doesn’t charge while you drive: with Deeck Bridge.
- Temperature: with a temperature sensor, Deeck compensates the charge.
- Expected curve and end time: the “Charging now” card also shows the expected curve and the time it should finish.
- The history: a year of charges instead of the last 7 days and, with Deeck Bridge, the lowest resting voltage of each day for the last 30 days.
- Safe with Deeck Bridge: the charge stops by itself if the engine starts and if the vehicle moves.
If the charge doesn’t start
- Engine running. With the engine running, the charge doesn’t start.
- No reading of the house battery’s charge. Deeck needs the house battery’s charge, from a battery monitor or a BMS read over Bluetooth, from a GX or from VRM: without it the charge doesn’t start.
- House battery below the threshold. Below 50 % the charge doesn’t start (with Deeck Plus you set the threshold from 20 to 95 %): let the sun or the mains charge it first.
- Starter battery type left unknown. If you answered that you don’t know, the charge doesn’t start: when Deeck asks, pick your starter battery.
- Deeck not up to date. You need Deeck 1.0.2 or later: update it from the App Store.
- With Deeck Bridge: Bridge not up to date, too far from the Orion, or iPhone on another network. Deeck Bridge must be updated to the latest version and within Bluetooth range of the Orion; for the emergency charge through the Bridge, the iPhone must be on the same network as the Bridge.
- Firmware older than 1.15. You need firmware 1.15 or later: check the Firmware line in VictronConnect (step 1).
- Orion not set up as a charger, or neither engine shutdown detection nor input voltage lock-out active: see step 2.
- It stopped because the Orion got too hot. With Deeck Bridge the charge stops if the Orion gets too hot and starts again once it has cooled down.
I use it on my own camper, with a lead-acid starter battery: if your Orion doesn’t behave as described here, tell me and I’ll look into it. Orion is a Victron Energy product; Deeck is independent and not affiliated with Victron.
Questions people ask
How do I switch it on in Deeck?
Update Deeck to the latest version (you need 1.0.2 or later), update the Orion XS to firmware 1.15 or later and set it up as a charger in VictronConnect. Then, with the engine off, open “Starter battery” in Deeck and tap “Emergency charge” (with Deeck Plus: “Charge now”): the first time, Deeck asks which starter battery you have.
Which firmware does the Orion XS need for reverse charging?
Firmware 1.15 or later, installed with VictronConnect (Victron lists VictronConnect 6.43 or later).
Why won’t the emergency charge start on my Orion XS?
The usual reasons: the engine is running, Deeck has no reading of the house battery’s charge, the house battery is below the threshold (50 %, or the one you chose with Deeck Plus), you answered that you don’t know which starter battery you have, Deeck or Deeck Bridge isn’t on the latest version, the firmware is older than 1.15, or the Orion is not set up as a charger with input voltage lock-out or engine shutdown detection active.
Do I need input voltage lock-out or engine shutdown detection?
One of the two, active, with the Orion set up as a charger: that is Victron’s requirement for the reverse charge.
Can I start the reverse charge when I’m away from the vehicle?
With Deeck Plus and Deeck Bridge on board, yes: the Bridge, on your Cerbo GX or on a Raspberry Pi with Venus OS within Bluetooth range of the Orion, starts it while you’re away. Without the Bridge you start it from nearby, over the iPhone’s Bluetooth.
Where do I see how the charge went?
In the charge history: type, duration, Ah, voltage and outcome of every charge, and the detail with its own chart. For free the last 7 days, with Deeck Plus a whole year.