Victron Orion XS 12/12-50A LiFePO4 settings: battery preset, engine detection and lock-out

Orion XS LiFePO4 settings come in two groups. The first is the battery side: pick a lithium preset, or build one from your battery’s datasheet. The second is what makes a DC-DC charger different from a solar or mains charger: it must know when the engine is running, so it charges your lithium house battery while you drive and never drains the starter battery when you’re parked.

This guide walks through both groups with the values Victron publishes for the Orion XS 12/12-50A, and explains engine shutdown detection, smart alternators and the input voltage lock-out in plain words.

Orion XS setup, step by step

  1. 1

    Open VictronConnect near the Orion XS and connect over Bluetooth. Victron recommends changing the PIN code in the product info, so that settings and information aren’t easy for others to reach.

  2. 2

    Battery preset: choose a lithium preset, or a user-defined one with the voltages from your battery’s datasheet.

  3. 3

    Current limits: output current within the battery’s maximum charge current, input current within what your alternator and wiring can deliver.

  4. 4

    Engine shutdown detection: pick smart alternator (the default) or regular alternator, to match your vehicle.

  5. 5

    Input voltage lock-out: keep the default 12.5 V in charger mode, and lower it only if the voltage drop in your input cable calls for it.

  6. 6

    Start the engine and check: above 14 V charging starts at once; between the delayed start voltage and 14 V it starts after 120 seconds.

Each step is explained below, with the values Victron publishes for the 12/12-50A.

Battery settings: the lithium preset

In VictronConnect, Settings › Battery settings › Battery preset selects the charge algorithm. You can accept a factory preset or enter your own values; absorption voltage, float voltage, storage voltage, bulk time limit, re-bulk voltage offset, adaptive absorption and absorption time are all preset but can be user-defined. Custom presets are stored in VictronConnect’s library (Orion XS manual, Battery settings).

SettingWhat Victron documents for lithium
Absorption timeFixed, 2 hours by default for lithium batteries
Absorption and float voltageSet by the preset you choose; the manual gives no fixed number. Compare them with your battery’s datasheet
Equalisation and temperature compensationDisabled in the Victron Lithium Smart Battery preset
Low-temperature cut-offConfigurable for lithium; works only when a BMV-712 or SmartShunt shares battery temperature over VE.Smart, and not when a BMS controls the charger
Re-bulkA new charge cycle starts when the voltage stays 0.1 V below the re-bulk voltage for one minute
Tail current (expert mode)Ends absorption when the charge current drops below the threshold; your datasheet decides whether you need it

Sources: Orion XS manual, General (absorption time) and Operation, configuration and monitoring.

Settings depend on your battery and its BMS. Victron says to “follow the battery manufacturer’s recommendations for your battery type” when editing a preset. If your battery has a BMS with an allowed-to-charge output, it can switch the Orion XS on and off through the remote connector.

Current limits: protect the alternator

LiFePO4 has a low internal resistance and will take all the current a charger offers; Victron notes that controlled charging “protects the alternator in lithium systems from overloading”. The Orion XS has two limits, each adjustable from 1 to 50 A in 0.1 A steps on the 50 A model: input current, what it draws from the starter side, and output current, what it delivers to the house battery. Set the input limit with your alternator and wiring in mind, and the output limit within your battery’s maximum charge current.

Engine shutdown detection

The Orion XS decides from the voltage at its input whether the engine is running. A regular alternator holds a fixed voltage, around 14 V on a 12 V system; a smart alternator, common on Euro 6 vehicles, can vary between 12.5 and 15 V and may switch off for a while during the drive. In VictronConnect you choose the alternator type, and each type comes with its own defaults.

Setting (12 V / 24 V)Smart alternator (default)Regular alternator
Start voltage: charging starts at once14 V / 28 V14 V / 28 V
Delayed start voltage13.3 V / 26.6 V13.8 V / 27.6 V
Delayed start delay120 s120 s
Shutdown voltage: engine considered off13.1 V / 26.2 V13.5 V / 27 V

The shutdown only takes effect after one minute below the shutdown voltage, so short dips don’t stop charging. Start and shutdown voltages can be set between 9 and 35 V. Change any value and the type becomes “User defined” (Orion XS manual, Engine shutdown detection).

When a smart alternator fools the detection

When a smart alternator switches off while you drive, the starter battery falls back to its resting voltage and the Orion XS can conclude the engine has stopped. Victron’s manual is candid that results vary “from vehicle to vehicle, even within the same brand and model”. Two ways out: lower the start and shutdown voltages a little, at the cost of a smaller margin, or wire an external engine-running signal to the remote L-pin, which forces charging on while it is present. Victron advises leaving engine shutdown detection enabled when you use the signal, and does not recommend using the ignition switch alone.

Switching detection off altogether (“forced charging”) means the Orion XS draws from the starter battery even with the engine off; then only the input voltage lock-out stops it.

Input voltage lock-out

The lock-out is the minimum input voltage at which charging is allowed; below it charging stops immediately. It is your starter battery’s last line of defence.

Mode (12 V / 24 V)Lock-outRestart
Charger mode12.5 V / 25 V12.8 V / 25.6 V
Power supply mode10.5 V / 21 V12 V / 24 V

Victron recommends at least 0.5 V between lock-out and restart, and says that with forced charging “in most applications 12.5V is sufficiently low”. Also account for the voltage drop in the input cable: the manual’s rule is lock-out ≤ shutdown voltage − cable drop, and its worked example gives 13.1 V − 0.55 V = 12.55 V. To size that cable so its drop stays small, use the 12 V cable size calculator.

Where Deeck fits

VictronConnect sets up the Orion XS; Deeck reads the Orion XS’s Bluetooth broadcast and shows, next to the SmartShunt, whether it is charging, at what power, and in which state. On the road that is the quick check that engine detection works: on CarPlay, the DC-DC row shows power flowing while you drive. On iPhone for free; CarPlay and Apple Watch with Deeck Plus. See Victron on CarPlay and SmartShunt on iPhone. With firmware 1.15 the Orion XS also charges the other way, from the house battery to the starter battery, and with Deeck 1.0.2 starter battery charging is in Deeck: charge the starter battery with the Orion XS; the setup, step by step: Orion XS firmware 1.15 and reverse charging.

Questions people ask

What are the Orion XS settings for LiFePO4?

Choose a lithium battery preset in VictronConnect, check its absorption and float voltages against your battery’s datasheet (absorption time is fixed at 2 hours by default for lithium), set the output current within the battery’s limit and the input current within your alternator’s.

Smart alternator or regular alternator on the Orion XS?

Choose the type your vehicle has. Smart alternator is the default, with a lower delayed start voltage (13.3 V) and shutdown voltage (13.1 V) on 12 V.

Why does my Orion XS stop charging while I drive?

Usually a smart alternator switches off and the voltage drops below the shutdown voltage for more than a minute. Lower the start and shutdown voltages slightly, or use an engine-running signal on the L-pin.

What input voltage lock-out should I set?

The default in charger mode is 12.5 V with restart at 12.8 V. Keep at least 0.5 V between them and allow for the voltage drop in your input cable.

Can the Orion XS charge the starter battery from the house battery?

Yes, with emergency reverse charge from VictronConnect (firmware v1.15 and VictronConnect v6.43 or later). It runs for 15 minutes and keeps the house battery at 12 V or above.

Settings done. Now check.

Charging while you drive, on the dash.

With Deeck Plus you see them actually work: 90 days of history and a push alert when something drifts.