Truma error codes: what the Combi W and E codes mean and what to check
A Truma error code tells you two things: the letter says how serious it is (W is a warning and the heater keeps running, E is a fault and it stops), the number says what happened. The two you’ll meet most often are E 517 H, the gas supply is interrupted, usually an empty or closed cylinder, and W 255 H, the heater has no 12 V or no contact with the panel.
Below: the most frequent codes from the troubleshooting guide in Truma’s CP plus manual, for the Combi gas and the Combi D diesel, with what each one means and what you can do yourself; the blinking LEDs of the analogue panels; and when it’s a job for the Truma service. Anything on the gas system itself is always a job for an authorised Truma service partner.
How to read a Truma code: W, E, H and A
On the CP plus panel and on the iNet X touchscreen a code has three parts: a letter for the type, a number, and a letter for the appliance.
| Part | Meaning |
|---|---|
| W | Warning: an operating value is out of range. The appliance keeps working, and the symbol goes away by itself once the value is back in range. |
| E | Fault: the appliance stops and the panel jumps straight to the fault screen. |
| Number | What happened, as in the tables below. |
| H or A | H = heater (Combi), A = air conditioner. |
For the Combi gas, Truma uses two number series: one for heaters built before April 2018 (W 17 H, E 112 H …) and one for heaters built from April 2018 (W 401 H, E 517 H …). The causes are the same, so look for your number in either column of the table. The iNet X panel shows a fault on its touchscreen together with a suggested remedy; once the cause is fixed, you acknowledge it on the panel.
Truma Combi gas: the most frequent fault codes
Summarised from the troubleshooting guide in Truma’s CP plus operating instructions. Where a row shows two codes, it is the same cause in the two series.
| Code (before 04/2018 · from 04/2018) | Meaning | What you can do |
|---|---|---|
| W 17 H · W 401 H | Hot water (summer) mode with an empty water heater | Switch the heater off, let it cool down, fill the water heater. |
| W 18 H · W 402 H | Warm air too hot | Clear the warm-air outlets and the circulated-air intake; check that all four warm-air ducts are connected. |
| W 21 H · E 621 H | Room temperature sensor or its cable faulty | Check that the sensor cable is plugged in; a faulty sensor is replaced by the service. |
| W 24 H · W 303 H, W 411 H | Battery getting low: below 10.4 V | Charge the battery. |
| W 44 H · W 302 H, W 418 H | Battery too low: below 10.0 V | Charge the battery; an old battery may need replacing. |
| W 43 H · W 301 H, W 417 H | Overvoltage: above 16.4 V | Check the battery voltage and the charging sources, such as the charger. |
| W 42 H · W 412 H | Window above the flue open (window switch) | Close the window. |
| W 45 H · W 407 H | No 230 V on a Combi E, or its 230 V fuse blown | Restore the 230 V supply; for the fuse, see your Combi manual. |
| W 45 H · W 419 H, E 632 H | Overheating protection of the electric heating tripped (Combi E) | Reset it as your Combi manual describes; if it trips again, call the service. |
| – · W 408 H | No gas in Mix mode | The electric heating carries on; check the gas supply as for E 507 H. |
| E 112 H to E 212 H · E 507 H, E 516 H, E 517 H | Gas supply interrupted | Cylinder, valves, regulator, flue: see the next section. |
| W 255 H | No 12 V at the heater, or no connection with the panel | Check the 12 V supply and the fuses: see the W 255 H section. |
| – · E 607 H | Maximum number of fault resets reached | Wait 15 minutes, then acknowledge the fault. |
| W 29 H · E 624 H | FrostControl heating element short-circuited | The heating element needs replacing. |
If your code isn’t in the table, or the remedy doesn’t help, Truma’s advice is to contact the Truma service.
E 517 H and the other gas codes: what to check
The gas codes (E 507 H, E 516 H and E 517 H on heaters built from April 2018; E 112, E 121, E 122, E 202, E 211 and E 212 H before) all mean that the heater gets no gas, or can’t burn it. For the whole group Truma lists these causes:
- Cylinder empty: switch to a full one.
- Cylinder valve or quick-acting valve closed: open them.
- Regulator iced up: in frost the gas pressure regulator can freeze; Truma’s remedy is a regulator heater (EisEx).
- Too much butane: below about 10 °C butane is unsuitable for heating, so use propane.
- Flue blocked: snow, ice or leaves on the combustion-air intake or the exhaust outlet on the outside wall; clear them.
- Regulator faulty: a job for an authorised service partner, like anything else on the gas system.
Once the cause is fixed, clear the code as Truma’s FAQ describes:
- 1
Fix the cause, for example by connecting a full cylinder.
- 2
Tap the rotary push button to acknowledge the code. If the display is dark, the first tap only switches on the backlight: tap again.
- 3
If there is heating demand, the heater starts again by itself.
A flashing code means wait. The heater is in a 15-minute lock: after the panel was switched off, after the 12 V supply was interrupted, or after the fault was cleared four times without the gas coming back. Leave the panel and the power on for those 15 minutes; then the code stops flashing and you can acknowledge it. Switching the panel off and on doesn’t clear a fault: it only locks the heater for another 15 minutes.
The RESET in the CP plus service menu (PR SET) is not a way to clear a code either: it sets the panel back to factory settings and searches for the connected appliances again.
W 255 H: no 12 V or no contact with the panel
W 255 H means the panel can’t reach the heater. Truma names three causes, in the order to check them:
- 12 V supply: is the vehicle’s 12 V system switched on, and are the fuses on the electrical block and on the heater electronics intact?
- Panel cable: is it firmly seated at the panel and at the heater?
- Electronics: if supply and cable are fine, the electronics may be faulty, which is for the service.
A W 255 H right after a panel reset is the same story: the panel searched for appliances and found no heater. Check the supply and the cable first, then run the search again.
Truma Combi D (diesel): fault codes
The Combi D diesel heater has numbers of its own. From the same Truma troubleshooting guide:
| Code | Meaning | What you can do |
|---|---|---|
| E 111 H | Room temperature sensor or its cable faulty | Check the sensor cable; a faulty sensor is replaced by the service. |
| E 122 H | Out of fuel: tank low or empty, or the vehicle on a slope | Refuel, then fill the fuel line as described under “Initial start-up” in the Combi D manual. |
| E 131 H | No connection between heater and panel | Check the panel cable at both ends. |
| E 132 H | FrostControl heating element short-circuited | The heating element needs replacing. |
| E 150 H | Warm air too hot | Clear the outlets and the circulated-air intake; check the four warm-air ducts. |
| E 151 H, E 152 H | Water too hot in winter or summer mode | Switch off, let it cool, fill the water heater; clear outlets and intake. |
| E 160 H | Undervoltage: below 10.2 V | Charge the battery. As a quick fix, switch off big consumers or run the engine until the heater is running (about 4 minutes); a battery that can’t hold up may be at the end of its life. |
| E 161 H | Overvoltage: above 16.4 V | Check the battery voltage and the charger. |
| E 162 H | Window above the flue open | Close the window. |
| E 164 H | No 230 V (Combi D E), 230 V fuse blown, or overheating protection tripped | Restore the 230 V supply; for the fuse and the reset, see your Combi manual. |
| E 170 H | Battery getting low: below 11.5 V | Save power, on lighting for example, and charge the battery. |
| W 255 H | No 12 V at the heater, or no connection with the panel | As on the gas Combi: supply, fuses, cable. |
Truma heater blinking yellow or red: the LED codes
Without a display, the analogue CP classic panel (CP E classic on the Combi E) speaks through its LEDs: green means running, yellow a warning, red a fault. Each sequence blinks half a second on and half a second off, then pauses for 5 seconds before it repeats: count the blinks.
Combi gas with the CP classic panel
| LED | Meaning | What you can do |
|---|---|---|
| Yellow 1× | Battery getting low, below 10.4 V; the heater keeps running | Charge the battery. |
| Yellow 2× | Battery below 10.0 V or above 16.4 V; the heater stops | Charge or replace the battery; check the charger. |
| Yellow 3× | Window above the flue open | Close the window. |
| Yellow 4× | Hot water mode with an empty water heater, or outlets or intake blocked | Switch off, let it cool, fill the water heater; clear outlets and intake. |
| Yellow 5× | Room temperature sensor or its cable | Truma service. |
| Yellow 7× | Panel or panel cable faulty | Truma service. |
| Yellow 8× | FrostControl heating element short-circuited | The heating element needs replacing. |
| Yellow 9× | Gas: valves closed (about 30 seconds after switching on), cylinder empty, regulator iced up, too much butane | Open the valves, change the cylinder, use EisEx or propane. |
| Red 1× to 8× | Fault in the heater | Truma service: the blink count helps the technician. |
| Green and red on after switching on | Electronics faulty | Truma service. |
| Green stays on after switching off | After-run to cool the heater down, up to 5 minutes | Nothing: it isn’t a fault. |
Combi D with the CP classic panel
| LED | Meaning | What you can do |
|---|---|---|
| Red 6× | Out of fuel: tank low or empty, or the vehicle on a slope | Refuel and fill the fuel line as in the Combi D manual. |
| Red, any other count, or steady | Fault in the heater | Truma service. |
| Yellow 1× | Battery getting low, below 11.5 V | Save power and charge the battery. |
| Yellow 2× | Below 10.2 V or above 16.4 V; on the Combi D 6 E also no 230 V | Charge the battery or check the charger; restore the 230 V supply. |
| Yellow 3× | Window above the flue open | Close the window. |
| Yellow 4× | Warm air or water too hot, or hot water mode with an empty water heater | Clear outlets and intake, check the four ducts, fill the water heater. |
| Yellow 5× | Room temperature sensor or its cable | Truma service. |
| Yellow 6× | Water too hot in summer mode | Fill the water heater. |
| Yellow 7× | Panel or panel cable faulty | Truma service. |
| Yellow 8× | FrostControl heating element short-circuited | The heating element needs replacing. |
To reset after a fault, switch the heater off once no LED is blinking any more, then switch it on again. Older Combi 4 and Combi 6 rotary panels have no yellow warning code and use the red LED for both: in their manual, a red LED blinking fast (5 Hz) means the window above the flue is open or the battery is below 10.0 V, a slow red blink (1 Hz) a battery below 10.4 V, and a red LED that comes on about 30 seconds after switching on means no gas or a blocked flue.
Truma faults on your iPhone with Deeck
Deeck shows on your iPhone the number of the fault the Truma iNet X panel reports and, for the most common ones, what to check, in the same app as your Victron battery monitor. With a fault active, Deeck won’t start the heater: it asks you to fix the fault and clear it on the panel. That matters because many of the codes above are about the 12 V battery (W 24 H, W 44 H, E 160 H, E 170 H, the yellow 1× and 2×): with the voltage and state of charge on the same screen, you see a battery running down before the heater stops in the middle of the night.
Truma in Deeck comes with Deeck Plus, next to your Victron: from the iPhone near the vehicle, and from afar through Deeck Bridge. Deeck talks to the iNet X panel; what it reads and controls is in the Truma iNet X guide, and if the panel won’t connect, see Truma iNet X app not connecting.
With a CP plus and an iNet Box, Deeck shows the fault code and its class as the box sends them, without explaining what they mean, and won’t let you start the burner while the fault is active. This works from the iPhone near the vehicle, with Deeck Plus; the iNet Box does not go through Deeck Bridge.
Recognised. Deeck recognises the iNet X panel by its protocol; I haven’t tested it on a real system yet: if anything looks off, tell me and I’ll fix it. Keep the panel within reach for anything critical.
When it’s a job for the Truma service
- A red LED code, a code that isn’t in the tables, or a fault that keeps coming back after you have fixed the cause.
- Anything on the gas system: regulator, hoses, valves, burner. Truma’s manuals leave repairs to qualified technicians.
- A smell of gas: put out any open flame, open windows and door, close the cylinder and the quick-acting valves, don’t smoke or use electrical switches, and have the whole system checked by a technician.
For a quick answer, have the appliance type and the serial number from the rating plate ready: Truma asks for them.
Truma, Combi, iNet X and EisEx are trademarks of Truma. Deeck is not affiliated with Truma; the names are used only to describe compatibility. The tables summarise Truma’s operating instructions; the manual of your heater takes precedence.
Questions people ask
What does E 517 H mean on a Truma?
The gas supply is interrupted, on Combi gas heaters built from April 2018. Most often the cylinder is empty or a valve is closed; in frost the regulator can ice up, and butane doesn’t work below about 10 °C. Fix the cause, then tap the rotary push button to acknowledge.
What does W 255 H mean on the CP plus?
The panel has no contact with the heater: the heater has no 12 V, a fuse has blown or the panel cable is loose. Check the supply and the cable; if both are fine, contact the Truma service.
How do I reset a Truma error code?
Fix the cause, then acknowledge the code on the panel: on the CP plus by tapping the rotary push button. A flashing code can’t be cleared for up to 15 minutes; don’t switch the panel off in the meantime. The RESET in the service menu does not clear faults.
Why is my Truma heater blinking yellow?
On an analogue CP classic panel a blinking yellow LED is a warning. Count the blinks: 1 or 2 are about the battery voltage, 3 is the window above the flue, 4 is overheating or an empty water heater. The tables above have the rest.
Why is my Truma Combi blinking red?
A red blink on the CP classic panel is a fault in the heater: contact the Truma service. On a Combi D, six red blinks are the exception: the heater is out of fuel.
Can I see Truma faults on my iPhone?
With the iNet X panel, yes: Truma’s iNet X app shows them, and Deeck shows the number of the fault the panel reports and, for the most common ones, what to check, next to your Victron battery, with Deeck Plus. With a CP plus and an iNet Box, Deeck shows the code and class the box sends, without explaining them, from the iPhone near the vehicle.