LiFePO4 voltage chart: state of charge for 12 V, 24 V, 48 V and per cell
A 12 V LiFePO4 battery at rest reads about 13.6 V when full, 13.0–13.2 V at half charge and about 12.0 V at 10%; per cell that’s 3.40 V, about 3.26 V and 3.00 V. For a 24 V battery multiply the cell voltage by 8, for a 48 V battery by 16.
Below: the voltage charts for 12, 24 and 48 V and per cell, the charge, float and cut-off voltages, the difference between resting voltage, voltage under load and voltage while charging, and the honest part: why between about 20% and 90% the voltage tells you surprisingly little, and what to use instead.
12 V LiFePO4 voltage chart
These are resting voltages: the battery has had no charge and no load for at least an hour. A 12 V LiFePO4 battery has four cells in series (4S), so the battery voltage is four times the cell voltage.
| State of charge | 12 V battery, typical | Range in makers’ charts | Per cell |
|---|---|---|---|
| 100% | 13.6 V | 13.3–13.6 V | 3.40 V |
| 90% | 13.4 V | 13.3–13.4 V | 3.35 V |
| 80% | 13.3 V | 13.25–13.3 V | 3.32 V |
| 70% | 13.2 V | 13.2–13.3 V | 3.30 V |
| 60% | 13.1 V | 13.1–13.15 V | 3.28 V |
| 50% | 13.05 V | 13.0–13.2 V | 3.26 V |
| 40% | 13.0 V | 12.9–13.1 V | 3.25 V |
| 30% | 12.9 V | 12.8–13.0 V | 3.22 V |
| 20% | 12.8 V | 12.5–12.9 V | 3.20 V |
| 10% | 12.0 V | 12.0–12.5 V | 3.00 V |
| 0% | 10.0 V | 10.0 V | 2.50 V |
The typical column is the middle of what battery and cell makers publish; the range column shows how far their charts differ. They agree at the top and the bottom and spread by 0.1–0.2 V in the middle, because cells, temperature and the rest time they assume are not the same. Charts compared: those published by several battery makers; cell limits from the EVE LF280K datasheet.
Right after a full charge a 12 V LiFePO4 rests around 13.5–13.6 V. Left alone for a day it can settle to 13.3–13.4 V while still practically full. That’s normal, and the first hint that the voltage alone is a rough guide.
24 V and 48 V LiFePO4 voltage chart
A 24 V LiFePO4 battery has 8 cells in series (8S, 25.6 V nominal), a 48 V battery 16 (16S, 51.2 V nominal). The same state of charge sits at the same cell voltage, so the columns are the cell voltage times 8 and times 16. Charge settings and the full 8S table are in the 24 V LiFePO4 voltage chart.
| State of charge | Per cell | 24 V battery (8S) | 48 V battery (16S) |
|---|---|---|---|
| 100% | 3.40 V | 27.2 V | 54.4 V |
| 90% | 3.35 V | 26.8 V | 53.6 V |
| 80% | 3.32 V | 26.6 V | 53.1 V |
| 70% | 3.30 V | 26.4 V | 52.8 V |
| 60% | 3.28 V | 26.2 V | 52.5 V |
| 50% | 3.26 V | 26.1 V | 52.2 V |
| 40% | 3.25 V | 26.0 V | 52.0 V |
| 30% | 3.22 V | 25.8 V | 51.5 V |
| 20% | 3.20 V | 25.6 V | 51.2 V |
| 10% | 3.00 V | 24.0 V | 48.0 V |
| 0% | 2.50 V | 20.0 V | 40.0 V |
Some 48 V rack batteries use 15 cells instead of 16 (48 V nominal). For those, multiply the per-cell column by 15: 100% is about 51.0 V, 50% about 48.9 V. The datasheet tells you the cell count.
Charging, float and cut-off voltages for a 51.2 V battery, 15-cell packs and rack batteries are covered in the 48 V LiFePO4 voltage chart.
Charging, float and cut-off voltages
| What | 12 V | 24 V | 48 V | Per cell |
|---|---|---|---|---|
| Absorption (bulk) voltage, usual range | 14.2–14.6 V | 28.4–29.2 V | 56.8–58.4 V | 3.55–3.65 V |
| Victron’s LiFePO4 preset and Lithium Battery Smart | 14.2 V for 2 h | 28.4 V | 56.8 V | 3.55 V |
| Float voltage (or float off) | 13.5–13.6 V | 27.0–27.2 V | 54.0–54.4 V | 3.38–3.40 V |
| Maximum cell voltage (cell datasheet) | 14.6 V | 29.2 V | 58.4 V | 3.65 V |
| End of discharge, Victron Lithium Battery Smart | 11.2 V | 22.4 V | – | 2.80 V |
| Discharge cut-off of the cell (cell datasheet) | 10.0 V | 20.0 V | 40.0 V | 2.50 V |
Victron recommends 14.2 V absorption for 2 hours and 13.5 V float for its 12.8 V Lithium Battery Smart, and uses the same values in the LiFePO4 preset of its solar chargers (Lithium Battery Smart, technical data). Its manual adds that the cells are balanced when all of them reach 3.55 V at the end of the charge (troubleshooting chapter). The 3.65 V and 2.5 V cell limits come from the cell maker’s datasheet.
Your battery’s datasheet comes first. The BMS of each battery has its own limits for charge voltage, cut-off and charging temperature. Where the datasheet and this chart differ, follow the datasheet. Device by device: Victron LiFePO4 settings.
Resting voltage, voltage under load and voltage while charging
The chart only works for resting voltage. The same battery at the same state of charge shows three different numbers depending on what it’s doing:
- At rest: no charge, no load, for an hour or more. This is the voltage the charts describe.
- Under load: the voltage sags with the current, because of the internal resistance of the cells, the BMS and the cables. An inverter running a kettle can pull a 12 V battery down by a few tenths of a volt, so a half-full battery can look nearly empty for as long as the load runs. In the cold the sag is larger.
- While charging: the voltage rises towards the charger’s setpoint. 14.0 V during the day on solar says the charger is working, not that the battery is full; at the end of absorption every battery reads the absorption voltage, whatever it held in the morning.
The cables add their own share: a long or thin cable between the battery and the place you measure, or between the battery and the charger, shows a different voltage from the one on the battery terminals. To size them so that the drop stays small, use the 12 V cable size calculator.
Why voltage is a poor fuel gauge between 20% and 90%
LiFePO4 cells have a very flat voltage curve. In the typical chart above, going from 30% to 80% moves the resting voltage of a 12 V battery by only 0.4 V, from 12.9 to 13.3 V: about 0.1 V for every 12% of charge. A recent charge, a running fridge, a cold night or the meter itself can move the reading by as much.
The curve only gets steep at the two ends: above about 13.4 V the battery is close to full, below about 12.8 V it’s close to empty. That makes voltage useful as an alarm near the edges, and very rough in the middle, where you spend most of your time. It’s also why the flat plateau is a good thing for your devices: they get a steady voltage almost to the end.
What does work is counting. A battery monitor with a shunt measures every amp that goes in and out and adds them up, so it knows the state of charge whatever the voltage says, and it resets to 100% each time the battery is fully charged. The BMS inside a lithium battery does the same counting for its own percentage. On a Victron system that’s a SmartShunt or BMV set up for LiFePO4; the key setting is explained in Victron tail current explained.
Read the real state of charge on your iPhone
Deeck shows the state of charge your shunt or BMS counts, not a guess from the voltage. With a Victron SmartShunt you get state of charge, voltage, current and the days of autonomy at your real consumption, live over Bluetooth, free on iPhone near your system; see SmartShunt on iPhone.
With Deeck Plus, next to your Victron, Deeck also reads the Bluetooth BMS of your lithium battery: charge, voltage, current, cell voltages and temperatures on one battery page. The cell voltages are a really useful voltage reading: at the end of a full charge they should sit within a few hundredths of a volt of each other. Which batteries Deeck reads, and with what status: lithium battery app for iPhone.
Planning a new system? The battery runtime calculator tells you how long your battery lasts with your loads.
Questions people ask
What voltage is 50% on a LiFePO4 battery?
At rest, about 13.0–13.2 V on a 12 V battery (around 3.26 V per cell), about 26.1 V on a 24 V battery and about 52.2 V on a 48 V battery. Because the curve is so flat, the same reading can mean anything from about 40% to 60%: a battery monitor gives you the real number.
Is 13.2 V full for a 12V LiFePO4 battery?
Not quite. At rest, 13.2 V is typically around 70%, but on the flat part of the curve it can be anywhere from about 50% to 80%. A full battery rests around 13.5–13.6 V right after charging and about 13.3–13.4 V after a day of rest.
What voltage is a dead LiFePO4 battery?
Around 10.0 V for a 12 V battery, which is 2.5 V per cell, the discharge limit in cell datasheets. Most BMS cut the battery off before that. Victron’s Lithium Battery Smart ends discharge at 11.2 V (2.8 V per cell). If your battery cut out, recharge it soon: Victron warns that even small loads can damage a lithium battery left at its cut-off.
What voltage should I charge a 12V LiFePO4 battery at?
Usually 14.2–14.6 V absorption, with float at 13.5–13.6 V or switched off, as your battery’s datasheet says. Victron recommends 14.2 V for 2 hours and 13.5 V float for its own lithium batteries and uses those values in its LiFePO4 presets.
Why does my LiFePO4 battery read 14 V or more?
Because it’s being charged. While a charger, solar or the alternator is working, the battery voltage follows the charge voltage. Switch off the charging and let the battery rest for an hour before you compare it with the chart.
Can I use a lead-acid voltage chart for a LiFePO4 battery?
No. A 12 V lead-acid battery is full at about 12.7 V, while a LiFePO4 at 12.8 V is close to empty. A lead-acid chart would call an almost empty lithium battery full. Use the LiFePO4 chart, or better, a battery monitor.