The Victron Blue Smart IP65 is a mains battery charger in a sealed plastic housing with no fan, rated IP65 (splash and dust proof). It comes in 12 V with 4, 5, 7, 10, 15 or 25 A and in 24 V with 5, 8 or 13 A, charges lead-acid and LiFePO4 batteries with a 7-stage adaptive algorithm, works as a 12 V or 24 V power supply and has Bluetooth built in for VictronConnect. It is light enough to carry, from 0.6 kg, and can also be screwed to a wall.
Below: the models and their currents, the full specifications, the charge stages and modes, the IP65 against the IP22 and the IP67, LiFePO4 settings, power supply mode, the LEDs, Instant Readout and what Deeck shows. Figures come from Victron’s Blue Smart IP65 manual (230 V), the IP65 datasheet and the datasheets of the IP22 and the IP67.
What the Blue Smart IP65 is
- Sealed and silent: cooling by convection, no fan and no moving parts. You may hear a click when the output relay switches.
- Interchangeable battery connection: a 1.5 m red and black cable fixed to the charger ends in a quick connector. M8 ring terminals and battery clamps are in the box; a cigarette lighter plug, fused ring terminals, spring clamps, MagCode connectors and a 2 m extension cable are optional.
- Portable or fixed: for a fixed installation Victron says to mount it vertically, mains cable facing down, with about 10 cm of free space around it, never on top of or directly above the battery.
- Recovers flat batteries: it starts charging from 0 V with low current, and it resets a lithium battery whose under-voltage protection has tripped.
- Bluetooth for setup, monitoring and firmware updates in VictronConnect, plus Instant Readout.
Victron also makes a small 6 V/12 V 1.1 A version and a 120 V version for North America, each with its own manual. This guide covers the 230 V models from 12/4 to 24/13.
Models: 12 V and 24 V
| Model | Current: max / low mode | Largest battery (Victron) | Size (h × w × d), weight |
|---|---|---|---|
| 12/4 | 4 A / 2 A | 40 Ah | 45 × 81 × 183 mm, 0.6 kg |
| 12/5 | 5 A / 2 A | 50 Ah | 45 × 81 × 183 mm, 0.6 kg |
| 12/7 | 7 A / 2 A | 70 Ah | 47 × 95 × 190 mm, 0.8 kg |
| 12/10 | 10 A / 3 A | 100 Ah | 60 × 105 × 190 mm, 0.9 kg |
| 12/15 | 15 A / 4 A | 150 Ah | 60 × 105 × 190 mm, 0.9 kg |
| 12/25 | 25 A / 10 A | 250 Ah | 75 × 140 × 240 mm, 1.9 kg |
| 24/5 | 5 A / 2 A | 50 Ah | 47 × 95 × 190 mm, 0.8 kg |
| 24/8 | 8 A / 3 A | 80 Ah | 60 × 105 × 190 mm, 0.9 kg |
| 24/13 | 13 A / 4 A | 130 Ah | 75 × 140 × 240 mm, 1.9 kg |
The largest battery is Victron’s figure for at least 0.1C in maximum current mode. For small batteries, low current mode keeps the current within limits: Victron gives about 0.3C as the usual maximum for lead-acid and about 0.5C for LiFePO4. For a motorhome with a 100 Ah leisure battery, the 12/10 or 12/15 fits; for 200 Ah of lithium, the 12/25.
Blue Smart IP65 specifications
| Blue Smart IP65 (230 V) | |
|---|---|
| Mains input | 220–240 VAC nominal, 180–265 VAC min/max; 50–60 Hz (45–65 Hz) |
| Max efficiency | 94 % (12 V models), 95 % (24 V models) |
| Standby power | 0.5 W |
| Current drawn from the battery without mains | 0.7 Ah per month (1 mA) |
| Power factor | > 0.6 |
| Charge algorithm | 7-stage adaptive (4 stages for Li-ion) |
| Temperature compensation | −16 mV/°C (12 V), −32 mV/°C (24 V), off in Li-ion mode |
| Protection | Reverse polarity, output short circuit, over temperature |
| Operating temperature | −40 to +50 °C; full output up to 30 °C, then linear derating to 25 % at 50 °C |
| Humidity | Max 95 % |
| Ingress protection | IP65 |
| Housing | Black plastic, convection cooling (no fan) |
| Mains cable | 1.5 m with CEE 7/16, CEE 7/17, BS 1363 or AS/NZS 3112 plug |
| Battery cable | 1.5 m, 16 AWG (12/4 to 12/7, 24/5), 14 AWG (12/10, 24/8), 12 AWG (12/15), 10 AWG (12/25, 24/13) |
| Communication | Bluetooth, through the VictronConnect app |
| Standards | EN 60335-1, EN 60335-2-29; automotive ECE R10 |
Victron recommends a fuse or circuit breaker in the battery cable, as close to the battery as practical, especially in a hardwired installation. The manual lists a minimum and maximum rating per model, for example 15 to 30 A for the 12/10 and 40 to 50 A for the 12/25.
Charge algorithm and modes
Each charge cycle runs through these stages:
- Test: checks that the battery takes charge, for up to 2 minutes, even close to 0 V.
- Bulk: maximum current until the absorption voltage. At the end a lead-acid battery is at about 80 %, a lithium battery above 95 %.
- Absorption: constant voltage, current falling. Adaptive by default, from 30 minutes to 8 hours depending on how deep the discharge was; fixed in Li-ion mode.
- Recondition (optional, lead-acid only): higher voltage at 8 % of the rated current, for at most 1 hour. Not for regular use.
- Float: the battery is full; 4 to 8 hours.
- Storage: a slightly lower voltage while the battery stays on the charger.
- Repeated absorption: 1 hour of absorption every 7 days to refresh a stored battery.
The three built-in modes, Normal, High and Li-ion, plus Recondition for the first two, set these voltages (24 V models in brackets):
| Mode | Absorption | Float | Storage |
|---|---|---|---|
| Normal | 14.4 V (28.8 V) | 13.8 V (27.6 V) | 13.2 V (26.4 V) |
| High | 14.7 V (29.4 V) | 13.8 V (27.6 V) | 13.2 V (26.4 V) |
| Li-ion | 14.2 V (28.4 V) | Disabled | 13.5 V (27.0 V) |
| Recondition stage | 16.2 V (32.4 V) after Normal, 16.5 V (33.0 V) after High |
Choose the mode with the MODE button or in VictronConnect under Charge preset; settings survive a disconnection. A new cycle starts when you change mode, when mains comes back, or when the charger delivers its maximum current for four seconds, for example with a large load on board. Victron’s advice: pick the mode that suits your battery type and follow the battery manufacturer’s recommendations.
IP65 vs IP22 vs IP67
All three are Blue Smart chargers with Bluetooth, the same Normal, High and Li-ion voltages, and the option to run as a power supply. What changes is the housing, the outputs and the currents:
| Blue Smart IP65 | Blue Smart IP22 | Blue Smart IP67 | |
|---|---|---|---|
| Outputs | 1, interchangeable connectors | 1 or 3 | 1; the 12/25 and 24/12 also come with a start interrupt output |
| Protection | IP65, splash and dust proof; plastic, no fan | IP22; aluminium | IP67, waterproof; cast aluminium, electronics moulded in resin |
| 12 V currents | 4, 5, 7, 10, 15, 25 A | 15, 20, 30 A | 7, 13, 17, 25 A |
| 24 V currents | 5, 8, 13 A | 8, 12, 16 A | 5, 8, 12 A |
| Efficiency | Up to 94 % / 95 % | 93 % / 94 % | 93 to 96 % |
| Operating temperature | −40 to +50 °C, full output to 30 °C | −40 to +60 °C, full output to 40 °C | −20 to +60 °C, full output to 40 °C |
| Weight | 0.6 to 1.9 kg | 1.3 kg | 1.8 to 2.4 kg |
| Who it suits | Motorhome or van: portable, or fixed in a garage or outdoor locker; on a boat, a single battery or the tender | Motorhome with a dry locker; boat with separate batteries on 3 outputs; up to 30 A | Boat engine room or deck, places that get wet; vehicles that must not start while plugged in |
In short: the IP65 is the light one that takes splashes and dust, the IP22 gives more current and three outputs for a dry spot, the IP67 is sealed in resin for the wettest places. The IP22 datasheet also lists VE.Smart networking, synchronised parallel charging of up to ten chargers. Phone app for the IP22: Victron IP22 app.
Blue Smart IP65 for LiFePO4
The IP65 has the same Li-ion mode as the IP22, with the same values in its manual: 14.2 V absorption, float disabled, 13.5 V storage (28.4 V and 27.0 V on 24 V), fixed absorption, no temperature compensation and no recondition. The full walk-through, with charge current and the SmartShunt, is in IP22 LiFePO4 settings: it applies to the IP65 too. What is specific to the IP65:
- Selecting it: press MODE until the LI-ION LED is on, or choose Li-ion under Charge preset in VictronConnect.
- Low current mode: hold MODE for 3 seconds; the LI-ION LED blinks. In VictronConnect it is in the Charge current menu.
- Smallest LiFePO4 battery at about 0.5C, according to the manual (12 V): 8 Ah on the 12/4, 10 Ah on the 12/5, 14 Ah on the 12/7, 20 Ah on the 12/10, 30 Ah on the 12/15, 50 Ah on the 12/25 at full current; in low current mode 4, 4, 4, 6, 8 and 20 Ah.
- Cold: Victron warns not to charge Li-ion batteries below 0 °C.
- Other voltages: if your battery’s datasheet asks for them, VictronConnect’s Advanced settings take a User defined preset.
Power supply mode
The IP65 can power 12 V or 24 V equipment at a constant voltage, with or without a battery connected: useful on shore power with the battery removed for winter, or on the bench. Victron recommends switching to Power supply mode for this, because it turns off the charge logic.
- 1
Plug the charger into mains and connect to it in VictronConnect.
- 2
Open Settings (the gear) and tap Charger in the Function field.
- 3
Select Power supply and confirm: the BULK, ABS, FLOAT and STORAGE LEDs light up together.
- 4
Set the output voltage if needed, and low current mode if you want it. To go back, choose Charger in the same field.
What the LEDs mean
| State | LEDs |
|---|---|
| Test | TEST blinking |
| Bulk | BULK on |
| Absorption | ABS on |
| Recondition | ABS on, RECONDITION blinking |
| Float | FLOAT on |
| Storage | STORAGE on |
| Power supply mode | BULK, ABS, FLOAT and STORAGE on |
| Low current mode | The selected mode LED (NORMAL, HIGH or LI-ION) blinks |
| Error | BULK, ABS, FLOAT and STORAGE blinking; the error code is in VictronConnect |
| MODE button locked | All LEDs flash when you press the button |
The button lock is a VictronConnect setting: the button can then only restart the cycle from bulk and reset Bluetooth. Handy when the charger hangs in a shared garage or a marina locker.
VictronConnect and Instant Readout
VictronConnect is where you set up the IP65: connect over Bluetooth with the PIN on the label on the back (or 000000 if there is no label), then change mode, current, advanced settings and firmware. Victron recommends changing the default PIN. The History screen keeps statistics for the last 40 charge cycles and the charger’s lifetime.
Instant Readout shows output voltage, output current, charge stage, warnings, alarms and errors in the device list without a full connection, and reaches further than a connection does. On the IP65 it needs firmware v3.61 or later and is off by default. How to switch it on, and what to check if the charger doesn’t appear, is in Victron IP22 app: the steps are the same for the IP65.
Your Blue Smart IP65 on your iPhone with Deeck
Deeck reads the IP65 over Bluetooth like the IP22, for free. The first time, Deeck asks for the charger’s Bluetooth PIN, the one on the label or 000000, and gets the Instant Readout key by itself (lost PIN: Victron Bluetooth PIN reset). The status is Recognised: Deeck recognises the IP65 by its protocol; if anything looks off, tell me and I’ll fix it.
- Output power in W, output voltage and current.
- Charge state, such as bulk, absorption or float.
- Error · Code N when the charger reports an error.
- Charts over 30 minutes, 24 hours and 7 days for free; 90 days with Deeck Plus.
Deeck only reads: it doesn’t change mode or current, which stay in VictronConnect. There is no alert specific to the charger; with a SmartShunt or BMV in the system, Deeck’s battery alerts (low charge, battery full, low or high voltage, high temperature) cover the battery side. Widgets are free; CarPlay, Apple Watch and remote access through Deeck Bridge come with Deeck Plus, an annual subscription at €39.99 a year.
Blue Smart and VictronConnect are Victron Energy products; Deeck is independent and not affiliated with Victron. Figures summarise Victron’s manual and datasheets; for your unit, the manual has the final word.
Questions people ask
What models does the Victron Blue Smart IP65 come in?
12 V with 4, 5, 7, 10, 15 or 25 A and 24 V with 5, 8 or 13 A, for 220–240 V mains. Victron also makes a 6 V/12 V 1.1 A model and a 120 V version.
Can the Blue Smart IP65 charge LiFePO4 batteries?
Yes, in Li-ion mode: 14.2 V absorption, float disabled, 13.5 V storage on 12 V. Victron warns not to charge below 0 °C. The settings are the same as on the IP22.
What is the difference between the Blue Smart IP65 and IP22?
The IP65 is sealed (splash and dust proof), fanless and light, from 4 to 25 A at 12 V with one output. The IP22 is an aluminium charger for a dry place, 15 to 30 A at 12 V, with one or three outputs.
Can the Blue Smart IP65 be used as a power supply?
Yes. Switch Function from Charger to Power supply in VictronConnect: the charge logic turns off and the output stays at a constant, adjustable voltage, with or without a battery.
Can I leave the Blue Smart IP65 connected all winter?
Yes: Victron writes that in storage the battery can stay on charge for a long time; the charger holds the storage voltage and gives 1 hour of absorption every 7 days. Without mains it draws 0.7 Ah per month from the battery.
Does the Blue Smart IP65 work with Deeck?
Yes, for free: Deeck reads output power, voltage, current, charge state and any error over Bluetooth, with the status Recognised. Settings stay in VictronConnect.