IP22 LiFePO4 settings: the Li-ion mode of the Blue Smart IP22 and IP65 chargers
IP22 LiFePO4 settings are the simplest in the Victron range: the Blue Smart IP22 has a built-in Li-ion charge mode, selected with the MODE button or in VictronConnect, and Victron describes it as suited to LiFePO4. The Blue Smart IP65 uses the same Li-ion values.
Below: what Li-ion mode sets, how to select it, how to choose the charge current for your battery, and the few things Victron warns about for lithium, starting with cold charging.
What Li-ion mode sets
| Stage | 12 V models | 24 V models |
|---|---|---|
| Absorption | 14.2 V | 28.4 V |
| Float | Disabled | Disabled |
| Storage | 13.5 V | 27.0 V |
| Recondition | Disabled | Disabled |
| Absorption duration | Fixed (automatic default in Li-ion mode) | Fixed |
| Temperature compensation | Off in Li-ion mode | Off in Li-ion mode |
Sources: Blue Smart IP22 manual, Charge modes and Blue Smart IP65 manual, Charge modes, which list the same Li-ion values.
For comparison, the lead-acid Normal mode is 14.4 V absorption, 13.8 V float and 13.2 V storage. If your IP22 has been charging a LiFePO4 battery in Normal mode, it has been charging it higher than Victron’s lithium mode does.
Settings depend on your battery and its BMS. Victron’s own notice: select a charge mode appropriate to the battery type and capacity, and “refer to the battery manufacturer’s recommendations”. If the datasheet asks for other voltages, VictronConnect’s advanced and expert settings allow user-defined values.
How to select Li-ion mode
On the charger
- 1
Press and release the MODE button to cycle through Normal, Normal + Recondition, High, High + Recondition and Li-ion.
- 2
Stop when the LED next to LI-ION lights up. The setting is stored and survives disconnecting mains or battery.
In VictronConnect
- 1
Connect to the charger and tap the gear icon to open Settings.
- 2
In the Charge preset menu, select Li-ion.
Source: Blue Smart IP22 manual, Setup. Recondition can’t be added to Li-ion mode.
Charge current for a LiFePO4 battery
Victron gives a typical upper limit: for LiFePO4 the charge current “should not exceed ~0.5C”, half the capacity in amps. A 30 A IP22 on a 40 Ah battery would be too much; on a 100 Ah battery it is well within. Your battery’s datasheet may set a lower figure, and that one counts.
- Low current mode limits the current to 50 % of the rated maximum and turns the fan off. Hold MODE for 6 seconds, or use the Charge current menu in VictronConnect; the NIGHT LED blinks.
- Night mode does the same for 8 hours, then returns to full current. Hold MODE for 3 seconds.
- A custom limit between 25 % and 100 % of the rated current can be set in VictronConnect.
Lithium specifics from Victron’s manual
- No charging below 0 °C. Victron’s warning: “Do not charge Li-ion batteries if the battery temperature is below 0°C.” With battery temperature data over VE.Smart networking, charging can be disabled automatically in the cold; the manual mentions “typically <5°C”.
- Batteries in protection. If the battery’s under-voltage protection has tripped, the IP22 automatically resets it and starts charging.
- Charge time. A LiFePO4 battery is above 95 % when bulk ends, and absorption to 100 % typically takes less than 30 minutes. Victron’s example: an empty 100 Ah battery on a 10 A charger needs about 9.5 + 0.5 = 10 hours.
- Tail current and loads. With loads running, part of the charger’s output goes to them, not the battery. A SmartShunt or BMV on the same VE.Smart network shares the real battery current, which the charger then uses for its tail current. More in Victron tail current explained.
Sources: IP22 manual, Features and Operation.
Matching the SmartShunt
In Li-ion mode the IP22 absorbs at 14.2 V, above the 13.9 V that Victron recommends as the SmartShunt’s LiFePO4 charged voltage, so the SmartShunt can recognise a full battery during absorption. Storage at 13.5 V sits below it, so the SmartShunt won’t synchronise on a battery that is only being maintained. Details in SmartShunt LiFePO4 settings.
What Deeck shows
VictronConnect sets up the charger; Deeck reads the IP22’s and IP65’s Bluetooth broadcast and shows the charger’s state and power next to the SmartShunt’s state of charge, so on shore power you can see from anywhere on board when the battery is full again. On iPhone for free; on CarPlay and Apple Watch with Deeck Plus. See SmartShunt on iPhone and Victron on CarPlay.
Questions people ask
Which IP22 mode for a LiFePO4 battery?
Li-ion mode. It charges at 14.2 V absorption (28.4 V on 24 V models), disables float and holds 13.5 V (27.0 V) in storage. Check those against your battery’s datasheet.
Does the IP22 float a lithium battery?
In Li-ion mode float is disabled according to Victron’s current manual; after absorption the charger holds the 13.5 V storage voltage.
What charge current for LiFePO4 on an IP22?
Victron says not to exceed about 0.5C, half the capacity in amps, unless your battery’s datasheet sets a lower limit. Low current mode halves the charger’s output.
Can I charge LiFePO4 below freezing with the IP22?
No. Victron warns not to charge Li-ion batteries below 0 °C. With battery temperature from a VE.Smart network, the charger can stop charging in the cold automatically.
Are the IP65 LiFePO4 settings the same?
Yes. The Blue Smart IP65 manual lists the same Li-ion values: 14.2 V absorption, float disabled, 13.5 V storage on 12 V.