SmartShunt LiFePO4 settings start from a simple fact: the SmartShunt leaves the factory set up for lead-acid batteries. Victron’s manual says the defaults “are tailored for lead acid batteries” and lists five settings to change for LiFePO4: charged voltage, tail current, Peukert exponent, charge efficiency and discharge floor. Add the battery capacity, which you always set, and you have the whole list.
Below: each setting with Victron’s default and its recommended LiFePO4 value, what it actually does, how synchronisation to 100 % works, and what “calibrating” a SmartShunt really means. The BMV-712 battery monitor has the same battery settings; its own manual lists the defaults for its firmware.
The settings table
In VictronConnect all of these are under Settings › Battery. Values for a 12 V battery unless stated.
| Setting | Factory default | LiFePO4 per Victron | Range |
|---|---|---|---|
| Battery capacity | 200 Ah | Your battery’s capacity in Ah | 1–32,500 Ah (firmware v4.19 and later; earlier: up to 9,999 Ah) |
| Charged voltage | 14.0 V / 28.0 V / 56.0 V | 13.9 V (12 V), 27.8 V (24 V), 41.7 V (36 V), 55.6 V (48 V) | 0–95 V |
| Tail current | 4.00 % | Higher than the current at which your charger stops charging | 0.50–10.00 % |
| Charged detection time | 3 minutes | No separate LiFePO4 value | 0–100 minutes |
| Peukert exponent | 1.25 | 1.01, unless the battery supplier advises otherwise | 1.00–1.50 |
| Charge efficiency factor | 95 % | 98 % | 50–100 % |
| Discharge floor | 50 % | 10–20 %, unless the battery supplier advises otherwise | 0–99 % |
| Battery SOC on reset | Keep SOC | No separate LiFePO4 value | Keep SOC, Clear, Set to 100 % |
Sources: SmartShunt manual, Make Lithium settings and All features and settings.
Settings depend on your battery and its BMS. Victron’s LiFePO4 values are a starting point; where your battery maker’s datasheet gives a different Peukert exponent, discharge floor or charge voltage, use the datasheet.
What each setting does
Battery capacity
The SmartShunt counts amp-hours in and out. Capacity tells it what 100 % is. The default is 200 Ah, so a 100 Ah or 280 Ah battery left at the default gives a wrong percentage from day one.
Charged voltage, tail current and charged detection time
These three work together to detect a full battery. When the voltage is above the charged voltage and the charge current is below the tail current and both last for the charged detection time, the SmartShunt sets the state of charge to 100 %. The tail current is a percentage of the battery capacity: 4 % of a 200 Ah battery is 8 A, Victron’s own example.
Victron adds a note that matters a lot with lithium: “some battery chargers stop charging when the current drops below a set threshold. In these cases, the tail current must be set higher than this threshold.” The whole topic, with the interaction with your chargers, is in Victron tail current explained.
Peukert exponent
Peukert compensates for the capacity a battery loses at high discharge currents. Lead-acid suffers from it, LiFePO4 hardly does, which is why Victron recommends 1.01 for lithium. A value of 1.00 switches the compensation off.
Charge efficiency factor
Not every amp-hour that goes in is stored. At 95 %, the SmartShunt counts 9.5 Ah stored for every 10 Ah charged. LiFePO4 is more efficient than lead-acid, so Victron recommends 98 %. If the percentage climbs too slowly or too fast while charging, this is one of the settings to check.
Discharge floor
Used for the time-to-go estimate and the default state-of-charge alarm. At the factory 50 %, the SmartShunt tells you the battery is “empty” at half charge, which suits lead-acid. Victron says lithium batteries can usually be discharged much deeper and suggests 10 to 20 %, unless your battery supplier says otherwise.
Battery SOC on reset
What happens to the percentage after the SmartShunt loses power, for example when you switch off the main DC isolator on a boat. Keep SOC (the default) resumes from the last stored value; Clear leaves it unknown until the next synchronisation; Set to 100 % assumes a full battery. It needs SmartShunt firmware 4.12 and Bluetooth firmware 2.42 or later; older units show a simpler “Start synchronized” on/off switch.
Synchronising: how the SmartShunt gets back to 100 %
State of charge is counted, so small errors add up over days. Victron calls the fix synchronisation: every time the battery is fully charged, the SmartShunt resets to 100 % and starts counting again from a known point (SmartShunt manual, Synchronising the battery monitor).
- Automatic. Happens by itself when the three full-charge conditions above are met. With LiFePO4 that means a charger that actually reaches absorption: a battery that is never fully charged never synchronises, and its percentage drifts.
- Manual. In VictronConnect, Settings › Battery › Synchronise sets 100 % on demand. Use it after the first installation, after the SmartShunt lost power, or when you know the battery is full but the SmartShunt missed it.
Two failure modes, both from Victron’s troubleshooting chapter. Too early: on solar, a charged voltage that is too low can be passed late in the day while the battery is not full; as the sun sets the current drops below the tail current and the SmartShunt jumps to 100 %. Raise the charged voltage closer to the absorption voltage, lengthen the detection time or lower the tail current. Never: a charged voltage above what the charger reaches, or a tail current below the charger’s cut-off, means no synchronisation at all; lower the charged voltage or raise the tail current (SmartShunt manual, Troubleshooting).
Calibrating a SmartShunt: what it really means
People search for “calibrating” the SmartShunt and mean one of two things. Most of the time it is the synchronisation above: telling the SmartShunt that the battery is full. The second is the zero current calibration, which fixes a current reading when nothing is flowing.
Victron is clear that a zero current calibration “is (almost) never needed”. Do it only if the SmartShunt shows a current while you are sure none flows, and the only way to be sure is to remove every cable from the system-minus side of the shunt. Switching loads and chargers off is not enough, because standby currents remain. Then press Calibrate in VictronConnect.
A related setting is the current threshold (default 0.10 A): currents below it are counted as zero, so tiny noise doesn’t slowly drain the calculated state of charge.
A warning from Victron on deep discharge
Victron’s Lithium settings chapter ends with a warning worth reading in full: a LiFePO4 battery that has been discharged to its BMS cut-off can be damaged by any remaining small load. The SmartShunt itself draws less than 12 mA. Victron’s example: a residual 1 mA can damage a 100 Ah battery left discharged for more than 40 days. If the vehicle or boat stands unused for long, isolate the battery with the main switch or by pulling the fuse.
SmartShunt Bluetooth PIN code: default and reset
VictronConnect asks for a PIN the first time you connect over Bluetooth. Per Victron’s manual, the SmartShunt’s unique PIN is printed on its serial number sticker; if the sticker shows none, the default is 000000, and Victron strongly advises changing it to your own in the product info. Lost the PIN? In VictronConnect’s device list, tap the menu next to the SmartShunt and reset it to 000000 with the PUK code printed on the product sticker (SmartShunt manual, Configuration; Reset PIN code).
Where Deeck fits
Every setting above lives in VictronConnect. Once they are right, Deeck shows the result on one dashboard: state of charge, voltage, current and days of autonomy at your real consumption, with a state-of-charge history that makes a missing or early synchronisation easy to spot. It works on iPhone for free, and on CarPlay and Apple Watch with Deeck Plus. See SmartShunt on iPhone and Victron on CarPlay.
Questions people ask
What charged voltage should I set on a SmartShunt for LiFePO4?
Victron recommends 13.9 V for 12 V, 27.8 V for 24 V, 41.7 V for 36 V and 55.6 V for 48 V. Keep it just below the absorption voltage your chargers actually reach.
What tail current should I set for LiFePO4?
Victron gives no single lithium value: the factory default is 4 % of capacity, and the rule is to set it higher than the current at which your charger stops or reduces charging. See Victron tail current explained.
What Peukert exponent for LiFePO4?
1.01, unless your battery supplier advises otherwise. The factory value of 1.25 is meant for lead-acid.
How do I calibrate a SmartShunt?
Charge the battery fully and let it synchronise, or press Synchronise in VictronConnect under Settings › Battery. The separate zero current calibration is almost never needed and requires disconnecting all cables from the system side of the shunt.
Why does my SmartShunt show 100 % too early?
On solar systems the charged voltage is often set too low. Raise it to just below the absorption voltage, lengthen the charged detection time or lower the tail current, as Victron’s troubleshooting chapter suggests.
Do these settings apply to the BMV-712 too?
The battery settings have the same names and meaning on the BMV-712. Check its own manual for defaults and ranges of your firmware.
What is the SmartShunt Bluetooth PIN code?