Victron BMV-700 and BMV-702: manual summary, settings and the difference between them

The Victron BMV-700 and BMV-702 are battery monitors with a head unit, a display with four buttons and a 500 A shunt. They measure battery voltage and current and calculate the state of charge, the time to go and the amp-hours consumed. The only difference: the BMV-702 has an auxiliary input that measures a second battery (such as the starter battery), the midpoint of a battery bank, or the battery temperature with an optional sensor. Neither has Bluetooth built in; both have a VE.Direct port for a GX device, a Bluetooth dongle or a USB interface.

Below: the BMV-700 and BMV-702 side by side and next to the BMV-712 Smart and the SmartShunt, how to wire the shunt, the settings for LiFePO4 and lead-acid, synchronisation, relay and alarms, the VE.Direct port, and how to see your BMV on your iPhone with Deeck. Figures come from Victron’s manuals for the BMV-700 and the BMV-702, including their technical data and settings chapters.

What the BMV-700 and BMV-702 are

Both monitors count the current flowing in and out of the battery and turn it into a state of charge, compensated for the Peukert effect and for charge efficiency. They also keep a history: deepest discharge, average discharge, number of cycles, lowest and highest voltage, days since the last full charge. Everything is readable on the head unit and in Victron’s VictronConnect app.

  • Systems: supply voltage 6.5–95 V DC, so 12, 24, 36 and 48 V banks. The charged voltage for 32 V is set by hand, since automatic detection only knows 12, 24 and 48 V.
  • Shunt: 500 A / 50 mV included, with M10 bolts. Larger shunts up to 9999 A, sold separately.
  • Battery capacity: 1 to 9999 Ah; from firmware v4.19 up to 32,500 Ah.
  • Accuracy: current ±0.4 %, voltage ±0.3 %; resolution 0.01 A, 0.01 V and 0.1 Ah with the 500 A shunt.
  • Head unit: flush mount, 63 mm front diameter, 69 × 69 mm bezel, 52 mm body 31 mm deep, IP55 and not meant for outdoor use. A 10 m RJ12 cable links it to the shunt.
  • Relay: programmable, 60 V / 1 A normally open, function can be inverted.
  • Current draw: under 4 mA with the backlight off.

Victron still lists both on its battery monitors page, with manuals and datasheet.

BMV-700 vs BMV-702: the aux input

Everything else is the same: shunt, display, relay, VE.Direct port, settings. The BMV-702 adds a +B2 terminal on the shunt and the readings, alarms and relay conditions that go with it.

BMV-700BMV-702
Aux input (+B2)NoneStarter battery voltage, midpoint or temperature
Fused red cables in the boxOneTwo (main battery and aux)
Temperature sensor for BMVNot supportedOptional, sold separately
Extra alarms and relay conditionsNoneLow and high starter voltage, midpoint deviation, low and high temperature
VersionsOneGrey and BMV-702 BLACK
  • Starter battery: the second red cable goes from +B2 to the positive of the second battery, whose negative must sit on the LOAD AND CHARGER side of the shunt. The BMV shows its voltage next to the main bank.
  • Midpoint: on a 24 or 48 V bank made of batteries in series, +B2 goes to the midpoint. The BMV shows how far the voltage of the top half deviates from the bottom half, in percent.
  • Temperature: with the Temperature sensor for BMV (a different sensor from the ones supplied with Victron inverter/chargers), which replaces the two red cables.

The function is chosen in the setup wizard or later under setting 69, Aux input.

BMV-700, BMV-702, BMV-712 Smart and SmartShunt compared

The BMV-712 Smart is the same kind of monitor with Bluetooth built in; the SmartShunt is the same measuring unit without the head unit. Victron has also previewed a touchscreen successor, the BMV-812 Smart: BMV-812 Smart vs BMV-712.

BMV-700BMV-702BMV-712 SmartSmartShunt
DisplayYes, four buttonsYes, four buttonsYes, four buttonsNone
BluetoothWith VE.Direct Bluetooth Smart dongleWith VE.Direct Bluetooth Smart dongleBuilt inBuilt in
Aux inputNoneStarter, midpoint or temperatureStarter, midpoint or temperatureStarter, midpoint or temperature
Shunt500 A, up to 9999 A500 A, up to 9999 A500 A, up to 9999 A300, 500, 1000 or 2000 A
Supply voltage6.5–95 V6.5–95 V6.5–70 V6.5–70 V
Current drawUnder 4 mAUnder 4 mAUnder 1 mAUnder 1 mA
RelayYesYesYes, bistableNo
VE.Direct portYesYesYesYes
In DeeckThrough a GX and VRM, Deeck PlusThrough a GX and VRM, Deeck PlusOn the iPhone over Bluetooth, freeOn the iPhone over Bluetooth, free

Sources: manuals of the BMV-712 Smart and the SmartShunt. App guides: Victron BMV-712 app and Victron SmartShunt app.

Installing the shunt and the head unit

The shunt sits in the negative cable of the battery. It is rated IP21, so it goes in a dry place, screwed down through its two 5.5 mm holes. Victron’s connection order:

  1. 1

    Connect the battery negative to the M10 bolt on the BATTERY ONLY side of the shunt, at 21 Nm maximum. Nothing else goes on this side or on the battery negative: anything connected there is left out of the state of charge.

  2. 2

    Connect the negative of the whole system to the LOAD AND CHARGER side: DC loads, inverter, chargers, solar chargers and every other charge source.

  3. 3

    Push the ferrule of the red fused cable into the +B1 terminal and put its M10 lug on the battery positive.

  4. 4

    BMV-702 only: wire +B2 for the starter battery, the midpoint or the temperature sensor.

  5. 5

    Plug the RJ12 cable into the shunt and into the back of the head unit. The display turns on and the setup wizard starts.

The head unit mounts in a panel, secured from behind or from the front, or on a wall with Victron’s wall-mount enclosure. RJ12 cables come from 30 cm to 30 m if the supplied 10 m doesn’t fit. With a larger shunt, move the circuit board onto it, then set Shunt current and Shunt voltage (up to 9999 A and 75 mV). Source: BMV-702 manual, Installation.

Setup wizard and how to change settings

On first power-up the BMV asks for the battery capacity: the default is 200 Ah, and for lead-acid Victron recommends the 20-hour (C20) rating. The BMV-702 then asks for the aux input function. Right after, the monitor sets its nominal voltage from what it measures:

Measured voltageNominal voltage set
Below 18 V12 V
18 to 36 V24 V
Above 36 V48 V
  • On the head unit: hold SETUP for two seconds, browse with + and −, edit with SELECT. Each setting has a number, for example 01 Battery capacity.
  • In VictronConnect: easier, according to Victron, but the BMV-700/702 need the VE.Direct Bluetooth Smart dongle (the only option on iPhone) or the VE.Direct to USB interface on a computer. VictronConnect can also reach the BMV remotely through a GX device.
  • Firmware: updated only through VictronConnect.
  • Factory reset: SETUP and SELECT together for three seconds, only when Lock setup (setting 64) is off.

After the wizard the BMV is set up for GEL, AGM or flooded lead-acid. With lithium a few more settings change, in the next section. Source: BMV-702 manual, Configuration.

Settings for LiFePO4 and lead-acid

Values for a 12 V battery unless stated. The defaults suit lead-acid; for LiFePO4 Victron changes five of them.

SettingDefault (lead-acid)LiFePO4 per VictronRange
01 Battery capacity200 AhYour battery’s capacity in Ah1–9999 Ah (32,500 Ah from firmware v4.19)
02 Charged voltage14.0 V (28.0 V at 24 V, 56.0 V at 48 V)13.9 V (27.8 V at 24 V, 41.7 V at 36 V, 55.6 V at 48 V)0–95 V
03 Tail current4.00 %Higher than the current at which your charger stops charging0.50–10.00 %
04 Charged detection time3 minutesNo separate value0–100 minutes
05 Peukert exponent1.251.01, unless the battery supplier advises otherwise1.00–1.50
06 Charge efficiency factor95 %98 %50–100 %
Discharge floor (head unit: setting 16)50 %10–20 %, unless the battery supplier advises otherwise0–99 %
  • Capacity defines 100 %. Left at 200 Ah on a 100 Ah battery, the percentage is wrong from day one.
  • Charged voltage, tail current and detection time together decide when the battery is full. The tail current is a percentage of capacity: 4 % of 200 Ah is 8 A. Victron: “some battery chargers stop charging when the current drops below a set threshold. In these cases, the tail current must be set higher than this threshold.” More in Victron tail current explained.
  • Peukert compensates for the capacity lost at high discharge currents: a lead-acid battery rated 100 Ah at C20 may give only 56 Ah when emptied in two hours. Victron advises not to change 1.25 except for lithium; 1.00 switches the compensation off.
  • Charge efficiency at 95 % means 10 Ah charged count as 9.5 Ah stored.
  • Discharge floor is where the time to go counts down to, and the default for the state-of-charge alarm.

Victron’s lithium warning: the BMV draws under 48 mW from the battery. If a lithium system stays unattended for a long time, interrupt the positive supply (battery switch, fuse) so the monitor and other small loads can’t drain it. The same LiFePO4 values, explained for the SmartShunt: SmartShunt LiFePO4 settings. Your battery maker’s datasheet has the final word.

Synchronisation: why the BMV shows “---” or drifts

The state of charge is counted, so small errors add up. Every time the battery is full, the BMV resets to 100 % and starts again from a known point. Victron’s 12 V example with factory settings: voltage above 14.0 V, charge current below 4 % of capacity (8 A on 200 Ah), both for 3 minutes.

  • “---” on the display: the BMV is not synchronised, usually just after installation or after it was without power. State of charge, consumed Ah and time to go come back after the first full charge or a manual synchronisation.
  • Manual synchronisation: hold + and − together for three seconds, or tap Synchronise in VictronConnect under battery settings.
  • 100 % too early: the charged voltage is too low. On solar the voltage can pass it late in the day while the battery isn’t full, and the setting sun brings the current under the tail current. Set it just below the absorption voltage.
  • Never 100 %: the charged voltage is above what the charger reaches, or the tail current is below the charger’s cut-off. The percentage then drifts.
  • After a power loss: setting 70 decides whether the state of charge stays unknown until the next synchronisation or starts at 100 %.

Source: BMV-702 manual, Operation.

Relay and alarms

The relay has a COM and a normally open contact on the back of the head unit. Out of the box it closes when the state of charge falls below 50 % and opens again at 90 %: Victron’s example is starting a generator and stopping it once the batteries are charged.

  • Relay modes: DFLT (the relay follows settings 16 to 31), CHRG (charger or generator control on state of charge and low voltage) and REM (controlled through VE.Direct).
  • Relay conditions: low state of charge, low and high voltage; on the BMV-702 also starter battery voltage, midpoint deviation and temperature. Voltage conditions must last more than 10 seconds. A minimum closed time and an off delay keep a generator running long enough.
  • Alarms: off by default. When enabled they show on the display with the buzzer and a flashing backlight, in VictronConnect while connected, and on a GX device and in VRM. The BMV-700 alarms on state of charge and battery voltage; the BMV-702 adds starter voltage, midpoint and temperature.

The VE.Direct port: GX, Bluetooth dongle, USB

The VE.Direct port on the back of the head unit is how a BMV-700 or BMV-702 talks to anything else. Victron writes that the BMV sends all its readings every second on this port.

  • GX device such as a Cerbo GX: a VE.Direct cable, 0.3 to 10 m, or the VE.Direct to USB interface. The GX shows every battery value locally and sends it to VRM, Victron’s remote portal. Setup and use: Victron Cerbo GX MK2 and Victron Cerbo GX app.
  • VE.Direct Bluetooth Smart dongle: adds Bluetooth for VictronConnect, the way to configure the BMV from an iPhone.
  • VE.Direct to USB interface: VictronConnect on a computer; on Windows USB is the only option.

Source: BMV-702 manual, Interfacing.

Your BMV-700 or BMV-702 on your iPhone with Deeck

Deeck is an independent iPhone app, with CarPlay and Apple Watch, that puts your Victron devices on one dashboard. Deeck reads a BMV-700 or BMV-702 through a Victron GX connected over VE.Direct and online in VRM, with Deeck Plus, from anywhere too. It appears as a battery: state of charge, voltage, current, power, time remaining and consumed amp-hours; for the BMV-702 also the second voltage of the aux input, the starter battery.

BMV-700, BMV-702, BMV-712 Smart, BMV-812 Smart, SmartShunt, Cerbo GX, VictronConnect and VRM are Victron Energy products; Deeck is independent and not affiliated with Victron. Figures summarise Victron’s manuals; for your installation, the manual has the final word.

Questions people ask

What is the difference between the BMV-700 and the BMV-702?

Only the auxiliary input. The BMV-702 can measure a second battery such as the starter battery, the midpoint of a battery bank, or the battery temperature with the optional Temperature sensor for BMV. Shunt, display, relay, VE.Direct port and settings are the same.

Does the BMV-700 have Bluetooth?

No. The BMV-700 and BMV-702 need the VE.Direct Bluetooth Smart dongle, plugged into the VE.Direct port, to connect to VictronConnect over Bluetooth. The BMV-712 Smart and the SmartShunt have Bluetooth built in.

What are the BMV-702 settings for a LiFePO4 battery?

Per Victron’s manual: charged voltage 13.9 V on 12 V (27.8 V on 24 V, 55.6 V on 48 V), Peukert exponent 1.01, charge efficiency 98 %, discharge floor 10–20 %, and a tail current higher than the current at which your charger stops. Enter your battery’s capacity in Ah. The same applies to the BMV-700.

Can the BMV-700 monitor a starter battery?

No, the BMV-700 has no aux input. To see the starter battery voltage next to the house bank you need a BMV-702, a BMV-712 Smart or a SmartShunt, with the aux input set to starter battery.

Why does my BMV show “---” instead of the state of charge?

The monitor is not synchronised, usually after installation or a power loss. Charge the battery fully so the BMV reaches its charged voltage and tail current, or synchronise it by hand: hold + and − for three seconds, or tap Synchronise in VictronConnect.

Can I see my BMV-700 or BMV-702 on my iPhone?

Yes. VictronConnect connects to it with the VE.Direct Bluetooth Smart dongle. Deeck reads it through a Victron GX connected over VE.Direct and online in VRM, with Deeck Plus, also from anywhere: state of charge, voltage, current, power, time remaining, consumed amp-hours and, on the BMV-702, the starter battery voltage.

On the dash and on your wrist

Your BMV-700 or BMV-702 on your iPhone, from anywhere.

Seeing it is free. Having it on the dash and on your wrist is Deeck Plus.

Put it on CarPlay and Watch Download the app free

Free app · Deeck Plus €39.99 a year · cancel anytime · 14 days to change your mind