What is tail current? Victron SmartShunt, MPPT and how they fit together

Tail current is the current a battery still takes at the end of a charge, while the charger holds the absorption voltage: when it gets small, the battery is nearly full. At Victron, tail current is one name for two different settings. On the SmartShunt (and BMV) it is a percentage of battery capacity that helps decide when the battery is full and the state of charge can be reset to 100 %. On the SmartSolar MPPT and the other chargers it is a current in amps that ends the absorption stage early. They work in opposite directions, and getting them to agree is what makes the SmartShunt synchronise reliably.

Below: what tail current is, the values Victron gives for each device, and how it interacts with the SmartShunt’s charged voltage on a LiFePO4 system.

What is tail current?

At the end of a charge, the charger holds a constant voltage (absorption) and the battery takes less and less current as it fills. That shrinking current is the “tail”. A low tail current, at the absorption voltage, means the battery is close to full. Victron devices use that signal in two places.

SmartShunt / BMVSmartSolar MPPT
What it doesWith charged voltage and detection time, decides the battery is full and sets 100 %Ends absorption early and switches to float
Unit% of battery capacityAmps
Default4.00 %2 A
LiFePO4No fixed value: higher than the current at which the charger stops charging0 A in the LiFePO4 preset (off)
Range or time0.50–10.00 %; condition held for the charged detection time (default 3 min)Current below threshold for 1 minute

Sources: SmartShunt manual, Battery settings; SmartSolar MPPT manual, Operation and Configuration and settings.

Tail current on the SmartShunt

The SmartShunt sets the state of charge to 100 % when all three conditions are true together: voltage above the charged voltage, current below the tail current, and both for the charged detection time. Victron’s own 12 V example with factory settings: above 14.0 V, under 4 % of capacity (8 A on a 200 Ah battery), for 3 minutes.

On a LiFePO4 battery Victron changes the charged voltage to 13.9 V (27.8 V at 24 V, 55.6 V at 48 V) but gives no lithium-specific tail current. What it does say: “some battery chargers stop charging when the current drops below a set threshold. In these cases, the tail current must be set higher than this threshold.” Otherwise the charger stops before the SmartShunt sees the current fall low enough, and the battery never counts as full.

Because the tail current is a percentage, the amps depend on capacity. On a 100 Ah battery the default 4 % is 4 A; on 300 Ah it is 12 A. Do the multiplication when you compare it with a charger’s threshold in amps.

Tail current on the MPPT and other chargers

On a SmartSolar MPPT, tail current is an expert-mode setting: when the charge current stays below it for one minute, absorption ends and float begins. The default is 2 A. The LiFePO4 preset sets it to 0 A, which disables it, so absorption always lasts the full 2 hours. Victron explains why: “so that the full absorption time is available for cell balancing”.

The Blue Smart IP22 and IP65 and the Orion XS have the same idea: absorption can end early when the charge current drops below the tail current threshold. If your battery maker specifies an end-of-charge current, this is where it goes, in a user-defined preset.

There is a catch. A charger measures its own output, not what goes into the battery. With the fridge and lights running, part of the output feeds the loads and the tail condition may never be met. Victron’s answer is VE.Smart networking: a SmartShunt or BMV shares the real battery current, and the chargers use that for their tail current (IP22 manual, Current sense).

Making them agree on a LiFePO4 system

Victron’s rule for the SmartShunt fits in two lines: set the charged voltage “just below the voltage at which the charger completes the charge cycle, usually the absorption voltage”, and the tail current “higher than the current at which the charger stops or reduces charging”. The charged detection time “makes sure that a short voltage peak does not cause a synchronisation” (SmartShunt manual, Synchronising).

  1. 1

    Find your chargers’ absorption voltage. With Victron’s LiFePO4 presets on the MPPT and the IP22 Li-ion mode it is 14.2 V on 12 V; with a user-defined preset, it is what your datasheet says.

  2. 2

    Set the SmartShunt’s charged voltage below it. Victron’s LiFePO4 value is 13.9 V.

  3. 3

    If a charger has a tail current enabled, convert both to amps and set the SmartShunt’s percentage above the charger’s threshold.

  4. 4

    Watch one full charge in VictronConnect. The SmartShunt should reach 100 % during absorption.

When it goes wrong

  • 100 % too early, often in the evening on solar. The charged voltage is too low: the voltage is above it while the battery isn’t full, and the falling sun brings the current under the tail current. Victron’s fix: raise the charged voltage to just below absorption, increase the detection time and/or lower the tail current.
  • Never 100 %. The charged voltage is above what the battery reaches, or the tail current is below where the charger stops. Lower the charged voltage and/or raise the tail current, and make sure the battery regularly gets a full charge.
  • Synchronises in float, not in absorption. With LiFePO4 the float voltage (13.5 V in Victron’s preset) sits below the 13.9 V charged voltage, so it can’t. If your SmartShunt still synchronises at float, check its charged voltage.

Source for both failure modes: SmartShunt manual, Synchronisation issues.

Settings depend on the battery and its BMS. A BMS can stop charging on its own before any tail current is reached; your battery maker’s datasheet is the reference for end-of-charge voltage and current.

Seeing it in daily use

Tail current and the other settings live in VictronConnect; Deeck shows the outcome: the SmartShunt’s state of charge and its history next to solar and charger power, so you can see on any day whether the battery went back to 100 % during absorption, and how many days of autonomy are left. On iPhone for free; on CarPlay and Apple Watch with Deeck Plus. See SmartShunt on iPhone and Victron on CarPlay.

Questions people ask

What is tail current?

The charge current a battery still accepts at the end of charging, while the charger holds the absorption voltage. It shrinks as the battery fills, so a low tail current means the battery is nearly full. Victron uses it on the SmartShunt, as a percentage, to detect a full battery, and on its chargers, in amps, to end absorption.

What is tail current on a Victron SmartShunt?

A percentage of battery capacity. When the charge current falls below it, with the voltage above the charged voltage, for the charged detection time, the SmartShunt considers the battery full and sets 100 %. The default is 4 %.

What tail current should I use for LiFePO4?

Victron gives no single lithium value. Keep the SmartShunt’s tail current above the current at which your charger stops or reduces charging; convert the percentage to amps for your capacity to compare.

Why is the MPPT tail current 0 A for LiFePO4?

In Victron’s LiFePO4 preset 0 A disables the tail current, so absorption runs the full 2 hours for cell balancing.

Is the SmartShunt tail current the same as the MPPT tail current?

No. The SmartShunt’s is a percentage used to detect a full battery; the MPPT’s is in amps and ends absorption. They have to be set so the SmartShunt sees the battery full before the charger stops.

My SmartShunt goes to 100 % too early. What should I change?

Raise the charged voltage to just below the absorption voltage, increase the charged detection time and/or lower the tail current, as Victron’s troubleshooting chapter recommends.

Settings done. Now check.

See your battery reach 100 %.

With Deeck Plus you see them actually work: 90 days of history and a push alert when something drifts.

Check it works Download the app free

Free app · Deeck Plus €39.99 a year · cancel anytime · 14 days to change your mind