24 V LiFePO4 voltage chart: state of charge of an 8S 25.6 V battery

At rest, a 24 V LiFePO4 battery (eight cells in series, 25.6 V nominal) shows about 27.2 V when full, 26.1 V at half charge, 25.6 V at 20% and 24.0 V at 10%. In daily use it lives between roughly 25.6 and 27.2 V; on the charger it climbs to 28.4–29.2 V, and a float setting, if you use one, holds it near 27.0–27.2 V.

This page has the 8S table with the matching cell voltage on every row, the absorption, float, cut-off and restart values that 24 V systems are usually set to, why a 25.6 V label and a 24 V system are the same thing, what changes when you build 24 V from two 12 V batteries, and why the middle of the chart can’t tell 40% from 70%.

24 V (8S) LiFePO4 state of charge table

These are resting values: the battery has had no charge current and no load for an hour or more. Every pack figure is eight times the cell figure, the same cell values used in our LiFePO4 voltage chart for 12 V, 24 V and 48 V, so you can move between the pages without the numbers drifting.

State of charge8S pack (25.6 V)Per cell
100%27.2 V3.40 V
90%26.8 V3.35 V
80%26.6 V3.32 V
70%26.4 V3.30 V
60%26.2 V3.28 V
50%26.1 V3.26 V
40%26.0 V3.25 V
30%25.8 V3.22 V
20%25.6 V3.20 V
10%24.0 V3.00 V
0%20.0 V2.50 V

Between 30% and 80% the whole 24 V pack moves by about 0.8 V, a tenth of a volt per cell. That is less than the difference between two cheap multimeters, or between a battery that charged an hour ago and one that charged yesterday. Above about 26.8 V you can say the battery is nearly full, and below about 25.6 V that it is getting low; anywhere in between, the voltage is a rough hint and nothing more.

Right after a full charge an 8S battery can rest at 27.2 V or slightly above, then drift down to around 26.7–26.9 V over the next day while it is still close to full. That slow settling is normal for LiFePO4.

24 V or 25.6 V: one battery, two labels

A LiFePO4 cell is rated at 3.2 V, so a string of eight gives 8 × 3.2 = 25.6 V, the number printed on most labels and datasheets. “24 V” is the class of the system around it. It comes from lead-acid: twelve cells of 2 V make a 24 V battery, and inverters, chargers, solar controllers and DC-DC converters have been built for that class ever since. A 25.6 V lithium battery belongs in a 24 V system, as long as every charging source is set to lithium values rather than a lead-acid profile.

Don’t read the nominal figure as a state of charge: an 8S pack at rest spends most of its time between about 26 and 26.8 V, and drops to 25.6 V only when roughly a fifth of its capacity is left. The 48 V equivalent, with sixteen cells, is in the 48 V LiFePO4 voltage chart.

Charging and cut-off settings for a 24 V LiFePO4

Setting8S packPer cell
Absorption (bulk), range most makers allow28.4–29.2 V3.55–3.65 V
Float, if your battery uses one27.0–27.2 V3.38–3.40 V
Highest cell voltage (cell datasheet)29.2 V3.65 V
Low-voltage cut-off of inverter or loads, usual choice23.2–24.0 V2.90–3.00 V
Restart after a cut-off, usual choice24.8–25.6 V3.10–3.20 V
BMS cell under-voltage protection, typical22.4 V2.80 V
Absolute discharge limit of the cell (cell datasheet)20.0 V2.50 V

One real example of how a maker narrows these ranges: Victron’s datasheet for the Lithium SuperPack NG 25.6 V gives a recommended charging voltage of 28 V, a float of 27 V, a charging range of 27–28.4 V and an end-of-discharge voltage of 22.4 V. Its recommended charge voltage sits below the top of the generic range, which is common with batteries that have their own BMS. The same battery can be connected in parallel but not in series, so two 12 V SuperPack NG batteries can’t be wired into a 24 V bank: for 24 V you use the 25.6 V model.

Whatever the battery, keep the settings in the right order: every charger stops below the point where the BMS would cut the charge, and the inverter or low-voltage disconnect switches off above the point where the BMS would cut the discharge. Then the BMS only steps in when something has gone wrong.

Your battery’s datasheet has the final word. Charge and float voltage, charge current, cut-off and the lowest temperature for charging are set by the maker for that battery and its BMS. The table shows ranges common on 24 V systems, not the right value for any specific model.

Two 12 V batteries in series or one 24 V battery

Wiring two 12 V LiFePO4 batteries in series gives 24 V too, but it creates a problem a single pack doesn’t have. Each battery has its own BMS, and each BMS balances only the four cells inside its own case. Nothing balances the two batteries against each other. If one ends up slightly fuller, it reaches its upper limit first at the end of every charge: with 28.4 V across the pair it may be at 14.6 V while the other is at 13.8 V, and its BMS stops the charge for the whole string before the second battery is full. At the bottom the emptier one shuts down first. Left alone, the gap tends to grow over the seasons.

Batteries that allow series use usually ask for two identical units of the same age, each charged to full on its own before they are connected, and some makers set a limit on how many can go in series or suggest a battery balancer. Check that the datasheet allows series at all, as the SuperPack NG example shows. A single 25.6 V battery avoids all of this: one BMS sees all eight cells, balances them together and gives one state of charge for the whole bank.

Why the voltage hides your state of charge in the middle

LiFePO4 has a very flat discharge curve, and adding cells in series doesn’t change its shape. Per cell, a 24 V battery behaves exactly like a 12 V one: about 3.22 V at 30% and 3.32 V at 80%. On top of that, the reading moves with the conditions:

  • Under load: 2 kW from a 24 V bank is close to 80 A, half the current of a 12 V system, but enough to pull the pack down by a few tenths of a volt and make a battery at 60% look nearly empty. The voltage recovers once the load stops.
  • While charging: the pack follows the charger, so 27.8–28.4 V on a sunny afternoon tells you the solar controller is in bulk or absorption, not how full the battery is.
  • Temperature and settling: a cold battery reads a little lower, and a battery that charged recently reads a little higher, for the same charge.

The reliable way is to count the amp-hours that go in and out. A battery monitor with a shunt on the negative cable, or the battery’s own BMS, does exactly that and resets to 100% when the battery reaches full. How to set one up: SmartShunt LiFePO4 settings; the charging values for each Victron device on one page: Victron LiFePO4 settings.

The real state of charge of your 24 V battery on iPhone

Deeck recognises a 24 V system on its own, so you don’t have to tell it the voltage of your bank. It shows the counted state of charge, not a guess from the voltage, from a Victron SmartShunt or BMV over Bluetooth, and Victron devices nearby are free in Deeck. It also reads the state of charge from a Victron Lynx Smart BMS or from a VE.Bus system.

If your 25.6 V lithium battery has its own Bluetooth BMS and the app recognises the brand, Deeck can show the battery’s own state of charge from it: that is a Deeck Plus feature. Which devices Deeck reads: supported devices.

Questions people ask

What voltage is a 24V LiFePO4 battery when full?

About 27.2 V at rest for an 8S (25.6 V) battery, 3.40 V per cell. While it is still on the charger it reads higher, usually 28.4–29.2 V, and after a day without charge or load it often settles to around 26.7–26.9 V while still close to full.

What is 50% on a 24V LiFePO4?

About 26.1 V at rest, 3.26 V per cell. Because the curve is so flat, anything from roughly 25.8 V to 26.6 V can mean 30% to 80%, so a shunt-based battery monitor or the battery’s BMS gives a much better answer than the voltage.

What should I set the charger to for a 24V LiFePO4?

Most 8S batteries accept an absorption voltage of 28.4–29.2 V (3.55–3.65 V per cell) and a float of 27.0–27.2 V, or no float. Many makers recommend less: Victron’s Lithium SuperPack NG 25.6 V, for example, asks for 28 V charging and 27 V float. Use the values in your battery’s datasheet.

When is a 24V LiFePO4 battery dead?

At rest, 24.0 V is about 10% left and 20.0 V (2.5 V per cell) is the absolute limit of the cells. In practice the BMS cuts the discharge first, often around 22.4 V (2.8 V per cell), and a good setup switches the inverter off at 23.2–24.0 V so the BMS never has to.

Can I make 24V with two 12V LiFePO4 batteries in series?

Only if both batteries’ datasheets allow series use, with identical batteries charged to full separately before you connect them. Each BMS balances only its own cells, so the two batteries can drift apart over time. Some batteries, such as the Victron Lithium SuperPack NG, can go in parallel but not in series. A single 25.6 V battery is the simpler choice.

Your battery, in Deeck Plus

Your 24 V battery, counted in amp-hours.

One app per battery is one too many. With Deeck Plus every Bluetooth BMS sits on the same deck as your Victron gear, on iPhone and Apple Watch.

See your battery in Deeck Download the app free

Free app · Deeck Plus €39.99 a year · cancel anytime · 14 days to change your mind