Victron LiFePO4 settings: SmartShunt, MPPT, Orion XS, IP22 and MultiPlus

Victron LiFePO4 settings are spread across five or six devices in a typical van, motorhome or boat: the SmartShunt counts, the SmartSolar MPPT, the Orion XS and the Blue Smart IP22 charge, and a MultiPlus charges from shore power. Each one has its own lithium preset or lithium mode, and most problems (a state of charge that never reaches 100 %, or reaches it too early) come from two devices that don’t agree on what “full” means.

This page is the map. The table below lists every device, the LiFePO4 settings that matter on it and where Victron documents them; each row links to a detailed guide. All numbers come from Victron’s own manuals, linked next to each table. Where Victron gives no number, we say so and send you to your battery’s datasheet.

Before you change anything

Your battery comes first. LiFePO4 batteries differ: cell count, BMS cut-off voltages, charge current limits and cold-charging rules are set by the battery maker. Victron’s presets are a sensible starting point, and Victron itself says they “can be adjusted if the battery manufacturer specifications advise otherwise”. When the datasheet and a preset disagree, follow the datasheet.

All settings on this page are changed in VictronConnect, Victron’s free app, over Bluetooth (or VE.Configure on a PC for the deeper MultiPlus options). Write down the current values before you change them; VictronConnect can also save a device’s settings to a file and load them back.

The values below are for a 12 V system unless stated. Victron’s chargers scale them by two for 24 V and by four for 48 V; the SmartShunt has its own table per voltage.

Every device at a glance

DeviceLiFePO4 settings that matterVictron’s value (12 V)Guide
SmartShunt / BMV-712Battery capacity, charged voltage, tail current, charged detection time, Peukert exponent, charge efficiency, discharge floorCharged voltage 13.9 V; Peukert 1.01; charge efficiency 98 %; discharge floor 10–20 %; tail current and detection time: factory 4 % and 3 minSmartShunt LiFePO4 settings
SmartSolar MPPTBattery preset (LiFePO4), absorption, float, re-bulk, tail current, low-temperature cut-offAbsorption 14.2 V for a fixed 2 h; float 13.5 V; tail current 0 A; re-bulk at float − 0.1 VMPPT LiFePO4 settings
Orion XS DC-DCBattery preset, engine shutdown detection, input voltage lock-out, input currentLithium absorption fixed at 2 h by default; lock-out 12.5 V, restart 12.8 VOrion XS LiFePO4 settings
Blue Smart IP22 / IP65Li-ion charge mode, charge current, low current modeAbsorption 14.2 V; float disabled; storage 13.5 V; no temperature compensationIP22 LiFePO4 settings
MultiPlus / MultiPlus-IILithium battery mode, absorption and float voltage, charge currentVoltages from the battery manual; lithium mode sets re-bulk to float − 0.2 V (max 13.5 V)MultiPlus LiFePO4 settings

Sources: SmartShunt manual, Lithium settings; SmartSolar MPPT manual, Operation; Orion XS manual; Blue Smart IP22 manual; VictronConnect guide for VE.Bus products.

The one rule that ties them together

The chargers decide when the battery is full; the SmartShunt has to recognise it. The SmartShunt resets its state of charge to 100 % when three conditions hold at the same time: the voltage is above its charged voltage, the current is below its tail current, and both have lasted for the charged detection time. Victron’s tip is short: set the charged voltage “just below the voltage at which the charger completes the charge cycle, usually the absorption voltage”, and the tail current “higher than the current at which the charger stops or reduces charging” (SmartShunt manual, Synchronising).

With Victron’s LiFePO4 values the numbers line up: the chargers absorb at 14.2 V, the SmartShunt’s charged voltage sits just below at 13.9 V, and the float voltage of 13.5 V stays under it. If you raise or lower the absorption voltage to match your battery, move the SmartShunt’s charged voltage with it. The details, with the typical mistakes, are in Victron tail current explained.

A sensible order to set things up

  1. 1

    Read your battery’s datasheet: charge voltage, float (or “no float”), maximum charge current, lowest charging temperature, and whether the BMS can stop charging by itself in the cold.

  2. 2

    SmartShunt first: battery capacity, charged voltage, Peukert, charge efficiency and discharge floor. Then charge the battery fully once and synchronise.

  3. 3

    Solar: select the LiFePO4 preset on the SmartSolar MPPT, or a user-defined preset if your datasheet asks for different voltages.

  4. 4

    Alternator: on the Orion XS pick the lithium preset, then check engine shutdown detection and the input voltage lock-out for your alternator.

  5. 5

    Shore power: on the IP22 or IP65 select Li-ion mode; on a MultiPlus enable lithium battery mode and enter the battery’s voltages.

  6. 6

    Watch one full charge: the SmartShunt should reach 100 % during absorption, not in the late afternoon and not never.

If several Victron devices sit on the same battery, a VE.Smart network lets the SmartShunt share battery voltage, current and temperature with the chargers. The chargers then use the real battery current for their tail current and, with a temperature sensor, can stop charging in the cold (MPPT manual, VE.Smart networking).

What Deeck does once the settings are right

VictronConnect sets all of these, and it stays the right tool for it. Deeck reads what your devices broadcast over Bluetooth Instant Readout and puts it on one dashboard: the SmartShunt’s state of charge, the solar, DC-DC and charger power, and how many days and hours the battery will last at your real consumption.

That is also the easiest way to check your settings in daily life. The state-of-charge history shows whether the SmartShunt goes back to 100 % after each full charge, or drifts for days. The free version shows the live deck and 7 days of history on iPhone; Deeck Plus adds CarPlay, Apple Watch and remote alerts. See SmartShunt on iPhone and Victron on CarPlay.

Questions people ask

What are the best Victron settings for LiFePO4?

Start from Victron’s LiFePO4 preset on each charger (on the MPPT: 14.2 V absorption for 2 hours, 13.5 V float, for 12 V) and set the SmartShunt to 13.9 V charged voltage, Peukert 1.01 and 98 % charge efficiency. Then compare every voltage with your battery’s datasheet and follow the datasheet where they differ.

Do all my Victron chargers need the same voltages?

They should all follow the same battery datasheet. The LiFePO4 presets of the SmartSolar MPPT and the Li-ion mode of the IP22 both use 14.2 V absorption for 12 V. A VE.Smart network goes one step further: it synchronises solar chargers and IP22 chargers so they change charge stage together.

Why does my SmartShunt never show 100 % with LiFePO4?

Usually the charged voltage is set above what the chargers actually reach, or the tail current is set below the current at which they stop charging. Lower the charged voltage just below the absorption voltage, or raise the tail current. See Victron tail current explained.

Do I need a low-temperature cut-off?

Only if your battery cannot block charging in the cold by itself. Victron’s MPPT manual suggests 5 °C for LiFePO4 as a starting point and says to check the battery supplier; the cut-off only works when a battery temperature reading reaches the charger through VE.Smart networking.

Can Deeck change my Victron settings?

Settings and firmware updates are VictronConnect’s job. Deeck reads your devices, leaves every setting as you made it and shows the result on iPhone, CarPlay and Apple Watch.

Settings done. Now check.

Settings done. Now see them work.

With Deeck Plus you see them actually work: 90 days of history and a push alert when something drifts.

Check it works Download the app free