Victron MultiPlus lithium settings: configuring the charger of a MultiPlus or MultiPlus-II for LiFePO4
Victron MultiPlus lithium settings for LiFePO4 matter more than on any other Victron charger, because a MultiPlus leaves the factory set for gel batteries. Its default charge profile is lead-acid, and Victron’s own manual warns that the standard charging voltage may not suit your batteries.
This guide stays at the level most motorhome and boat owners need: what the defaults are, what lithium battery mode changes, which battery types VictronConnect can configure and which need VE.Configure on a PC. VE.Configure and VE.Bus systems with several units have many more options; for those, Victron’s documentation and an installer are the right place.
The factory defaults are for lead-acid
From the MultiPlus-II 230 V manual, the charger’s standard settings are:
| Setting | Factory default (12 V / 24 V / 48 V) |
|---|---|
| Battery type | Victron Gel Deep Discharge (also suitable for Victron AGM Deep Discharge) |
| Charge curve | Four-stage adaptive with BatterySafe mode |
| Absorption voltage | 14.4 V / 28.8 V / 57.6 V |
| Absorption time | Up to 8 hours, depending on bulk time |
| Float voltage | 13.8 V / 27.6 V / 55.2 V |
| Storage voltage | 13.2 V / 26.4 V / 52.8 V (not adjustable) |
| Repeated absorption | 1 hour every 7 days |
| Charging current | 100 % of the maximum |
Source: MultiPlus-II 230 V manual, Configuration. Victron calls the four-stage adaptive curve “the recommended charge algorithm for lead acid batteries”; with VE.Configure the charge algorithm “can be adjusted to charge any battery type”, lithium-ion included.
Settings depend on your battery and its BMS. Victron’s manual says settings may only be changed by a qualified electrical engineer, and that the AC input must be removed while configuring the charger. If you are not sure, have an installer do it.
What lithium battery mode changes
In VictronConnect, the charger settings of a VE.Bus device include a Lithium battery mode checkbox. Victron’s configuration guide describes exactly what it does (VictronConnect configuration guide for VE.Bus products):
| Feature | Lithium mode off (default) | Lithium mode on |
|---|---|---|
| Temperature compensation | Lead-acid algorithm | None: voltages stay fixed between 5 and 40 °C |
| Re-bulk voltage (12 V) | 1.3 V below float, at most 12.9 V | 0.2 V below float, at most 13.5 V |
Values are for 12 V; Victron multiplies them by two for 24 V and by four for 48 V. Its example: at 48 V, lithium re-bulk is float − 0.8 V with a maximum of 54 V. Lithium mode does not set the absorption and float voltages for you: those you enter yourself.
Which LiFePO4 battery do you have?
Victron’s guide splits lithium batteries into three cases, and the right setup depends on which one is yours.
- Batteries with a built-in BMS (“drop-in”). The usual LiFePO4 battery in a motorhome or van, with its own BMS that can interrupt charge and discharge. Enable lithium battery mode and set the charge voltages from the battery’s manual. No Assistants or other configuration are needed, so VictronConnect is enough.
- Victron 12.8 V and 25.6 V batteries with a VE.Bus BMS. They need extra configuration that VictronConnect doesn’t support: use VE.Configure, install the VE.Bus BMS Assistant and tick the lithium battery checkbox.
- Smart batteries connected to a GX device with DVCC. The checkbox has no effect: the battery sends its charge parameters over CAN-bus and they override the charger settings.
Setting up a drop-in LiFePO4 in VictronConnect
VictronConnect configures a MultiPlus through an MK3-USB interface on the VE.Bus port; Victron’s guide lists the VE.Bus Smart dongle for status mode (Connecting). For a single unit and a drop-in battery, the steps are short:
- 1
Disconnect the AC input, as Victron requires during charger configuration.
- 2
Open the charger settings in VictronConnect and enable Lithium battery mode.
- 3
Enter the absorption and float voltages from your battery’s datasheet.
- 4
Set the charge current within the battery’s maximum, keeping in mind that solar and DC-DC chargers may add to it.
- 5
Set maximum absorption time and the charge curve (adaptive or fixed) as your battery maker recommends.
- 6
Reconnect AC and watch the first charge: absorption at the voltage you set, then float.
Two more settings from Victron’s guide: Storage mode lowers the voltage below float after 24 hours in float, and Stop after excessive bulk switches the charger off if absorption voltage isn’t reached within 10 hours.
Then set the SmartShunt’s charged voltage just below the absorption voltage you entered, so it recognises the full battery: see SmartShunt LiFePO4 settings and Victron tail current explained.
Larger systems
VE.Configure exposes much more: Assistants, ESS, parallel and three-phase systems and the VE.Bus BMS. Victron points to VE.Bus Quick Configure Setup for up to three units and VE.Bus System Configurator for four or more. Those are installer territory, covered in the MultiPlus-II manual.
Where Deeck fits
VictronConnect and VE.Configure set up the MultiPlus; Deeck shows MultiPlus and Quattro through a GX and VRM, where they are tested on a real system, with their live status next to the SmartShunt’s state of charge on one dashboard and days of autonomy once you unplug from shore power. Nearby, Deeck also reads the Multi straight from the iPhone through the VE.Bus Smart dongle, recognised by its protocol, with no GX and for free: see VE.Bus Smart dongle. The VRM route, CarPlay and Apple Watch come with Deeck Plus. See SmartShunt on iPhone and Victron on CarPlay.
Questions people ask
What are the Victron MultiPlus lithium settings for LiFePO4?
For a drop-in LiFePO4 battery: enable lithium battery mode in VictronConnect and enter the absorption and float voltages from the battery’s manual. Batteries with a VE.Bus BMS need VE.Configure and the VE.Bus BMS Assistant.
Does lithium mode set the right voltages automatically?
No. It switches off temperature compensation and narrows the re-bulk gap (0.2 V below float, at most 13.5 V on 12 V). The charge voltages come from your battery’s datasheet.
Can I configure a MultiPlus for LiFePO4 with VictronConnect only?
For a drop-in battery with its own BMS, yes. For Victron lithium batteries with a VE.Bus BMS, Victron says to use VE.Configure.
What is the default absorption voltage of a MultiPlus-II?
14.4 V on 12 V, 28.8 V on 24 V and 57.6 V on 48 V, with float at 13.8 / 27.6 / 55.2 V. These are lead-acid values.
Does the MultiPlus setting matter with a CAN-bus battery?
With a smart battery connected to a GX device with DVCC, the battery’s CAN-bus parameters override the charger settings.