Victron Lynx: Distributor, Power In, Class-T, Shunt and Smart BMS explained

Victron Lynx is a modular DC distribution system: the modules bolt together side by side into one continuous positive and negative busbar for 12, 24 or 48 V systems. The Lynx Distributor, Lynx Power In, Lynx Class-T Power In and Lynx Shunt VE.Can are each rated 1000 A continuous. The Distributor adds four MEGA-fused connections with fuse monitoring, the Power In four unfused connections, the Class-T Power In two Class-T fused battery connections, the Shunt VE.Can a main fuse and a battery monitor, and the Lynx Smart BMS and Lynx Smart BMS NG a battery management system with a 500 A or 1000 A contactor for Victron lithium batteries.

Below: what each module does, how they connect and in which order, fuses and fuse monitoring, which combination fits lead-acid, AGM, Victron lithium or other batteries, when you need a GX device, and what Deeck shows on your iPhone. Figures come from Victron’s manuals for the Lynx Distributor, Lynx Power In, Lynx Class-T Power In, Lynx Shunt VE.Can and Lynx Smart BMS, and from the datasheets of the Lynx Smart BMS and Lynx Smart BMS NG.

The Lynx modules at a glance

Victron’s current range has six Lynx modules, all with M10 busbar joints. Each one carries a positive and a negative busbar, so wherever you bolt two modules together both poles continue.

ModuleWhat it addsCurrent ratingFusesCommunication
Lynx Distributor4 fused connections, an LED per fuse1000 A continuous4 MEGA fuses, sold separatelyRJ10 to a Lynx Smart BMS for fuse status
Lynx Power In4 unfused connections1000 A continuousNone: fuse every circuit externallyNone
Lynx Class-T Power In2 fused battery connections1000 A continuous2 Class-T fuses up to 400 A, sold separatelyNone
Lynx Shunt VE.CanMain fuse holder and battery monitor1000 A continuousMain fuse: CNN, ANL or MEGA, sold separatelyVE.Can to a GX device
Lynx Smart BMS / Smart BMS NGBMS, contactor, pre-charge, battery monitor500 A or 1000 A continuousNone: not a system fuseBluetooth and VE.Can

At 1000 A, Victron puts the power a Lynx busbar is rated for at 12 kW on 12 V, 24 kW on 24 V and 48 kW on 48 V; a 500 A Smart BMS halves that (6, 12 and 24 kW). With an inverter or inverter/charger, remember the batteries feed both the DC and the AC side.

Lynx Distributor: MEGA fuses and fuse monitoring

The Lynx Distributor is the fused module of the system: a positive busbar with four fused connections and a negative busbar with four connections plus a ground connection. It takes MEGA fuses, which you buy separately: 36 V-rated MEGA fuses for 12 and 24 V systems, 58 V-rated for 48 V. Voltage range 9–60 V, IP22.

  • One LED per fuse. In normal operation the power LED is green and the fuse LEDs are off. A blown or missing fuse turns its fuse LED red and the power LED red. A yellow power LED means the busbar has no voltage, for example when the main fuse in a Lynx Shunt VE.Can has blown.
  • Fill all four places. Victron asks you to place all four fuses even if you use fewer circuits, or a dummy fuse, so the red warning LED stays off.
  • Power over RJ10. The Distributor has no power supply of its own for fuse detection: a Lynx Shunt VE.Can or a Lynx Smart BMS powers it through the 40 cm RJ10 cable in the box. Without either, the LEDs don’t work unless you supply 5 V to the RJ10 yourself, as the manual describes.
  • Fuse status as data only with a Smart BMS. Up to 4 Distributors send their fuse status to a Lynx Smart BMS, which shows it in VictronConnect and passes it to a GX device and VRM, with an alarm when a fuse blows. With a Lynx Shunt VE.Can the LEDs work but the status isn’t communicated. Communication needs a Distributor with serial number HQ1909 or later.

With a Smart BMS and several Distributors, you address them A, B, C and D from left to right with a two-way DIP switch inside each one, so the alarms point to the right unit, and you can name each fuse in VictronConnect (up to 16 characters; an empty name takes that fuse out of monitoring). One particularity from the manual: when batteries are connected to several Distributor circuits and one battery fuse blows, the alarm only triggers once the battery is being charged or discharged.

The total of all fuses must not exceed the current rating of the Lynx module, or of the lowest-rated module in the line. Size fuses and cables for the maximum current each circuit can carry; for cable cross-sections the inverter cable size guide and the cable size calculator help.

Lynx Power In and Lynx Class-T Power In

Lynx Power In is the plain Lynx busbar: positive and negative, four connections for batteries, loads or chargers, and a ground connection, rated 1000 A, IP22. It has no fuses, so every battery, load or charger connected to it needs its own external fuse. In Victron’s lead-acid example it joins four 12 V batteries in parallel, with identical cable lengths for each battery.

Lynx Class-T Power In connects and fuses up to two strings of lithium batteries with Class-T fuses, which you buy separately; Victron lists ratings from 225 to 400 A and doesn’t stock them. With two 400 A fuses at most 800 A flows through one Class-T Power In; for three or more strings you add more Class-T modules, and the 1000 A total must not be exceeded. It is rated 1000 A continuous, 9–60 V, IP20.

Lynx Shunt VE.Can: main fuse and battery monitor

The Lynx Shunt VE.Can combines a positive busbar with a holder for the main system fuse and a negative busbar with a shunt for battery monitoring. Its battery monitor works like the other Victron battery monitors and reports state of charge, voltage, current and temperature with the sensor included in the box.

  • Main fuse: designed for a CNN fuse, it also takes an ANL fuse, or a MEGA fuse on the M6 bolts. Victron stocks a 325 A / 80 V CNN fuse. A piece of busbar in the box replaces the fuse if you want the main fuse elsewhere, useful in larger systems.
  • Fuse monitoring: a fuse installed in the shunt is monitored; if it blows, the power LED turns red and an alarm goes to the GX device.
  • Read through a GX only: no Bluetooth and no display. It connects to a GX device over VE.Can, with the profile «VE.Can & Lynx Ion BMS (250 kbit/s)», not on the BMS-Can port, and the GX shows its data locally and in VRM.
  • Relay: programmable from the GX on state of charge, voltage, temperature or a blown fuse, for example to start or stop a generator.
  • Ratings: 1000 A continuous, supply voltage 9–70 V for 12, 24 or 48 V systems, no reverse polarity protection.

Lynx Smart BMS and Lynx Smart BMS NG

Both are battery management systems that sit in the Lynx line: a positive busbar with a contactor driven by the BMS and a negative busbar with a shunt for the battery monitor. The contactor is a secondary safety, in case the primary controls (allow-to-charge and allow-to-discharge contacts, DVCC) fail to stop chargers or loads, and it doubles as a remote main switch. A pre-charge circuit limits inrush current into inverters. Victron is explicit that neither is a system fuse: fusing goes in the Distributors or external fuse holders.

Lynx Smart BMSLynx Smart BMS NG
BatteriesVictron Lithium Battery Smart, 12.8 and 25.6 VVictron Lithium NG, 12.8, 25.6 and 51.2 V
Batteries per systemUp to 20Up to 50 (25 with 48 V batteries)
Versions500 A and 1000 A, M10500 A and 1000 A, M10
Contactor peak600 A / 1200 A for 5 minutes600 A / 1200 A for 5 minutes
DVCC through a GXCompatible Victron inverter/chargers and solar chargersAlso Orion XS DC-DC chargers; cell voltages and temperatures on the GX and VRM
  • Allow-to-charge and allow-to-discharge ports (0.5 A at 60 V) switch chargers and loads with a remote on/off input; a programmable relay works as an alarm relay or switches off an alternator through its regulator.
  • AUX output of 1.1 A keeps a GX device powered after the BMS has turned off the loads on a low cell voltage; the BMS and AUX switch off if no charge voltage arrives within 5 minutes.
  • Bluetooth and Instant Readout: VictronConnect sets up and monitors the BMS, and Instant Readout shows voltage, current, state of charge and time remaining in the device list. Victron notes that Bluetooth can be disabled from VictronConnect or a GX but re-enabled only from a GX.
  • Parallel redundancy: up to 5 Lynx BMSs, each with its own bank, form one redundant system; Smart BMS and Smart BMS NG can be mixed, with the same current rating.

How the Lynx modules connect

With a Lynx Shunt VE.Can or a Lynx Smart BMS in the line, the batteries always connect on the left and all loads and chargers on the right, so the state of charge is calculated correctly. Mounted upside down, the sides swap, and Victron includes stickers to turn the front text the right way. A typical line, left to right: battery module, Shunt or Smart BMS, then Distributors.

  1. 1

    Plan the line: Power In, Class-T Power In or a Distributor for the batteries on the left, the Lynx Shunt VE.Can or Smart BMS in the middle, Distributors for inverter/charger, chargers and DC loads on the right. With a single battery or one series string, Victron allows connecting it straight to the Smart BMS input.

  2. 2

    Join the busbars: remove the red and black rubber sleeves where a module connects on the left, and tighten the busbar bolts to 33 Nm (17 Nm on units with a serial number before HQ2340). M10 modules don’t connect directly to the discontinued M8 ones.

  3. 3

    Connect the RJ10 cable from each Distributor to the Shunt or Smart BMS; with a Smart BMS and several Distributors, set the addresses A to D from left to right.

  4. 4

    Place the fuses: MEGA fuses in all four Distributor places, the main fuse in the Shunt, Class-T fuses in the Class-T Power In.

  5. 5

    Make one ground connection if the system needs one, after the Smart BMS, Lynx Shunt VE.Can or battery monitor shunt.

  6. 6

    Set it up: the Smart BMS and the Distributor fuse names in VictronConnect, the Lynx Shunt VE.Can on the GX device.

Which Lynx combination for which system

The choice between Lynx Shunt VE.Can and Lynx Smart BMS depends on the battery. Victron writes that the Lynx Smart BMS can only be used with Victron Lithium Battery Smart batteries, and the NG version with Victron Lithium NG batteries; the Lynx Shunt VE.Can suits all other batteries. Monitoring is optional: Power In, Class-T Power In and Distributor also work on their own.

SystemBattery sideIn the middleLoad sideGX device
Fused busbar, no monitoringPower In, Class-T Power In or DistributorNothingDistributorNot used; Distributor LEDs off unless powered
Lead-acid or AGM bankPower In, identical cables per batteryLynx Shunt VE.Can with main fuseDistributorNeeded to read the battery monitor
Victron Lithium Battery SmartDistributor or Class-T Power InLynx Smart BMSDistributorRecommended by Victron, powered from AUX
Victron Lithium NGDistributor or Class-T Power InLynx Smart BMS NGDistributorRecommended by Victron, powered from AUX
Other batteries, other-brand lithium includedPower In, Class-T Power In or DistributorLynx Shunt VE.CanDistributorNeeded to read the battery monitor

With the Lynx Smart BMS, Victron’s lithium examples put the Lithium Battery Smart batteries on a Distributor or a Class-T Power In, the Smart BMS next, a second Distributor for the inverter/charger, chargers and loads, and the allow-to-discharge signal to a Smart BatteryProtect for DC loads (Victron Smart BatteryProtect).

Do you need a GX device?

  • Lynx Shunt VE.Can: yes. It has no Bluetooth and no display; Victron says to use a GX device, such as a Cerbo GX, to read it, also for setup and the relay.
  • Lynx Smart BMS and NG: works without, better with. Bluetooth and VictronConnect cover setup and monitoring. The GX adds DVCC control of compatible Victron chargers and inverter/chargers, VRM remote monitoring, and Distributor fuse alarms on the GX and VRM. Victron recommends a GX powered from the BMS AUX output.
  • Distributor, Power In, Class-T Power In: no. They don’t talk to a GX themselves; the Distributor’s fuse status reaches the GX only through a Smart BMS connected over VE.Can.

GX options and setup: Victron Cerbo GX MK2. For remote monitoring of Bluetooth devices without a GX: Victron remote monitoring without GX.

Your Lynx on your iPhone with Deeck

Lynx Smart BMS: Deeck reads it directly on the iPhone over Bluetooth, from its Instant Readout broadcast, free, without Deeck Plus. It appears as a battery bank on the dashboard, on its device page and in the history, with state of charge, voltage, current, power, amp-hours consumed and time remaining; temperature too, when the BMS broadcasts it. Victron’s manual explains how to switch Instant Readout on in VictronConnect, under Product info.

Status in Deeck: Recognised. Deeck decodes it according to Victron’s format; if anything looks off, write to me and I’ll fix it. Deeck doesn’t show the contactor state or the BMS alarms, sends no alerts for the BMS and sends it no commands; the allow-to-charge and allow-to-discharge signals to an Orion XS or a MultiPlus aren’t shown either. Settings and alarms stay in VictronConnect and on your GX.

  • Lynx Shunt VE.Can: it has no Bluetooth, so Deeck reads it through a GX device online in VRM, with Deeck Plus and its remote access. It appears as a battery monitor with state of charge, voltage, current and power. The state of its main fuse isn’t read.
  • Lynx Smart BMS NG: not yet among the devices Deeck reads.
  • Lynx Distributor, Lynx Power In, Lynx Class-T Power In: Deeck doesn’t read or show them, the Distributor fuse status included.

Next to the Lynx, Deeck shows the rest of your Victron system on the same screen: a SmartShunt, SmartSolar chargers, an Orion XS and more (Victron SmartShunt app, supported devices).

Lynx Distributor, Lynx Power In, Lynx Class-T Power In, Lynx Shunt VE.Can, Lynx Smart BMS, Lynx Smart BMS NG, SmartShunt, Cerbo GX, VictronConnect and VRM are Victron Energy products; Deeck is independent and not affiliated with Victron. Figures summarise Victron’s datasheets and manuals; for your installation, the manual has the final word.

Questions people ask

Do I need a Lynx Shunt if I have a SmartShunt?

Not necessarily: both are Victron battery monitors with a shunt. The SmartShunt is read over Bluetooth in VictronConnect and Victron lists it for any battery type; the Lynx Shunt VE.Can adds a main fuse holder inside the Lynx busbar and is read through a GX device. One detail: a Lynx Distributor takes the power for its fuse LEDs from a Lynx Shunt VE.Can or a Lynx Smart BMS over the RJ10 cable; without either, the LEDs only work if you supply the RJ10 with 5 V yourself.

Lynx Distributor vs a busbar: what is the difference?

The Lynx Distributor is a positive and negative busbar with four MEGA-fused connections, an LED per fuse, and fuse status sent to a Lynx Smart BMS. It bolts to the other Lynx modules and is rated 1000 A continuous. If you want the Lynx busbar without fuses, that is the Lynx Power In, and every circuit then needs an external fuse.

Can I use the Lynx Smart BMS with non-Victron batteries?

No. Victron writes that the Lynx Smart BMS can only be used with Victron Lithium Battery Smart batteries, and the Lynx Smart BMS NG with Victron Lithium NG batteries. For all other batteries Victron indicates the Lynx Shunt VE.Can.

What fuses go in a Lynx Distributor?

MEGA fuses, bought separately: 36 V-rated for 12 and 24 V systems, 58 V-rated for 48 V. Place all four, a dummy fuse where a circuit is unused, and keep the total of all fuses within the current rating of the lowest-rated Lynx module.

How much current can a Lynx system carry?

Lynx Distributor, Power In, Class-T Power In and Shunt VE.Can are rated 1000 A continuous, which Victron puts at 12 kW on 12 V, 24 kW on 24 V and 48 kW on 48 V. The Lynx Smart BMS and Smart BMS NG come in 500 A and 1000 A versions; the lowest-rated module sets the limit for the line.

Does Deeck show my Lynx?

The Lynx Smart BMS yes, free on the iPhone over Bluetooth: state of charge, voltage, current, power, amp-hours consumed and time remaining. Status: Recognised. The Lynx Shunt VE.Can through a GX and VRM with Deeck Plus. Deeck doesn’t show the Distributor fuses, the Power In or the Class-T Power In.

On the dash and on your wrist

Your Lynx Smart BMS, live on your iPhone.

Seeing it is free. Having it on the dash and on your wrist is Deeck Plus.