Victron Smart BatteryProtect: models, wiring, settings for LiFePO4 and error codes
The Victron Smart BatteryProtect is an electronic switch between your battery and your DC loads: when the battery voltage stays too low, it cuts the loads off before the battery is damaged or can no longer start the engine. It comes in 65 A, 100 A and 220 A for 12/24 V and in 100 A for 48 V. Out of the box it disconnects at 10.5 V and reconnects at 12 V (21/24 V on 24 V, 42/48 V on 48 V), and you change that in VictronConnect over Bluetooth. Never wire an inverter or a MultiPlus through it: switch those with their remote on/off input instead.
Below: the four models, how to wire the battery, loads, ground, remote and alarm terminals, every preset and operating mode, which settings make sense with a LiFePO4 battery, what each error code means, and how the Smart BatteryProtect differs from the older BatteryProtect. Every figure comes from Victron’s Smart BatteryProtect 12/24V manual (rev 05, February 2025), the 48V manual and the datasheets.
What the Smart BatteryProtect does, and which model you need
The Smart BatteryProtect disconnects non-essential loads before the battery is completely discharged. It also works as a system on/off switch through its remote input, and it protects your loads from over-voltage: the load is switched off when the DC voltage goes above about 16 V on a 12 V system, about 32 V on 24 V and 64 V on the 48 V model. Inside there are MOSFETs, not relays, so it makes no sparks. Current flows in one direction only, from the IN terminal (battery) to the OUT terminal (loads).
| Model | System | Continuous current | Peak current | Terminals | Weight |
|---|---|---|---|---|---|
| SBP-65 | 12/24 V | 65 A | 250 A | M6 | 0.2 kg |
| SBP-100 | 12/24 V | 100 A | 600 A | M8 | 0.5 kg |
| SBP-220 | 12/24 V | 220 A | 600 A | M8 | 0.8 kg |
| SBP 48V-100 | 48 V | 100 A | 250 A | M8 | 0.8 kg |
The 12/24 V datasheet gives the peak current for 30 seconds. Pick the model by the continuous current of everything on the OUT side. Full load is rated from −40 °C to +40 °C, and at 50 °C up to 60% of the nominal load. The operating voltage range is 6–35 V for the 12/24 V models and 24–70 V for the 48 V model. Self-consumption with Bluetooth on is 1.4 mA when the output is on and 0.9 mA when it is off or after a low-voltage shutdown (1.9 mA and 1.7 mA on the 48 V model).
The 12/24 V models detect the system voltage once, at the first power-up, and store it. If you move the unit to a system with a different voltage, trigger detection again with “d” on the programming pin or set it in VictronConnect.
Smart BatteryProtect or the older BatteryProtect
Both come in 65 A, 100 A and 220 A, disconnect 90 seconds after the voltage drops below the shutdown level, reconnect 30 seconds after it rises above the restart level, ship with the same 10.5 V/12 V thresholds and have a Li-ion mode for an external BMS. The difference is Bluetooth: the older BatteryProtect has no Bluetooth, so you choose from its preset levels, shown on its 7-segment display; the Smart BatteryProtect can be set to any engage and disengage level in VictronConnect, shows its data through Instant Readout in the VictronConnect device list without pairing, and still has the programming pin. Bluetooth can be switched off if you don’t want it.
How to wire a Victron Smart BatteryProtect
- 1
Position: a well-ventilated spot, preferably within 50 cm of the battery, but not above it because of possible corrosive gases.
- 2
IN terminal: battery positive, through a fuse sized to local regulations. Size the cable for the load: voltage drop on a long or thin cable between battery and Smart BatteryProtect can trigger a short-circuit alarm when a load starts, or an unexpected shutdown.
- 3
GND: the supplied 1.5 mm² wire goes straight to the battery negative (or the vehicle chassis), with nothing else on it. Protect it with a fuse; 300 mA is enough.
- 4
Program before you connect the OUT terminal: system voltage, mode and thresholds, as in the next section.
- 5
OUT terminal: the DC loads.
- 6
Remote H and L: a wire loop between L and H comes fitted from the factory. Remove it and the load is switched off at once. For a system on/off switch, wire it between H and L, or switch H to battery positive, or L to battery negative. The load connects 1 second after the remote input closes and disconnects immediately when it opens.
- 7
Alarm output (optional): a buzzer, LED or relay between the alarm terminal and battery positive, matched to the system voltage, 50 mA at most (short-circuit proof). It switches on after the voltage has been below the shutdown level for 12 seconds, so starting the engine doesn’t set it off.
Never on the DC input of an inverter or a MultiPlus
Victron is explicit: under no circumstances may an inverter or inverter/charger, a MultiPlus included, be connected through a Smart BatteryProtect on its DC input. The capacitors at the inverter’s input trip the short-circuit protection (error E1), and a reverse current can flow that damages the unit. If you want the Smart BatteryProtect to switch an inverter off on low voltage, let it control the inverter’s remote on/off port, and connect the inverter’s DC cables straight to the battery side through their own fuse. The cable size for that run is in our inverter cable size guide.
Loads or a charger, never both
The Smart BatteryProtect handles current in one direction only: either to a load, or from a charger, never both at the same time. Don’t put a solar charger, DC-DC charger or any other charging source on the OUT side of a load Smart BatteryProtect: reverse current from OUT to IN is forbidden and can damage it permanently. To disconnect a charger, use a second Smart BatteryProtect turned the other way round, with the charger’s positive on IN, and no loads on its IN side. Never use one for battery-to-battery charging: if the OUT voltage is higher than the IN voltage, current flows backwards uncontrolled.
Victron Smart BatteryProtect settings
In VictronConnect: with only IN and GND connected, open the Smart BatteryProtect, tap the gear icon, check the detected battery voltage, choose the mode (A, B or C), choose Relay or Buzzer/LED for the alarm output, then pick a preset or tap User defined and set Shut down and Restart yourself. Under Product info you can change the PIN, give the unit a name and switch Bluetooth off; once off, only the programming pin brings it back.
With the programming pin: remove the wire loop from the remote terminal and connect PROG to GND with a wire or a push button. The display steps through presets 0 to 9; let go at the one you want and the display confirms it twice together with mode A. Connect again and let go at b or C to change the mode.
| Display | Shutdown 12 V | Restart 12 V | Shutdown 24 V | Restart 24 V | Shutdown 48 V | Restart 48 V |
|---|---|---|---|---|---|---|
| 0 (factory) | 10.5 V | 12.0 V | 21.0 V | 24.0 V | 42.0 V | 48.0 V |
| 1 | 10.0 V | 11.5 V | 20.0 V | 23.0 V | 40.0 V | 46.0 V |
| 2 | 9.5 V | 11.5 V | 19.0 V | 23.0 V | 38.0 V | 46.0 V |
| 3 | 11.25 V | 13.25 V | 22.5 V | 26.5 V | 45.0 V | 53.0 V |
| 4 | 11.5 V | 13.8 V | 23.0 V | 27.6 V | 46.0 V | 55.2 V |
| 5 | 10.5 V | 12.8 V | 21.0 V | 25.6 V | 42.0 V | 51.2 V |
| 6 | 11.5 V | 12.8 V | 23.0 V | 25.6 V | 46.0 V | 51.2 V |
| 7 | 11.8 V | 12.8 V | 23.6 V | 25.6 V | 47.2 V | 51.2 V |
| 8 | 12.0 V | 13.0 V | 24.0 V | 26.0 V | 48.0 V | 52.0 V |
| 9 | 10.0 V | 13.2 V | 20.0 V | 26.4 V | 40.0 V | 52.8 V |
Preset 0 is the factory setting. A dash (–) on the display means user-defined levels set over Bluetooth.
| Display | What it sets |
|---|---|
| A | Buzzer or LED mode (default) |
| b | Relay mode |
| C | Lithium (Li-ion) mode |
| d | Detect the system voltage again (12/24 V models) |
| F | Bluetooth on |
| h | Bluetooth off |
| P | PIN code reset; remove the old pairing from your phone afterwards |
Mode A, buzzer or LED: on low voltage a continuous alarm starts after 12 seconds; after 90 seconds the load is switched off and the alarm stops. The load comes back 30 seconds after the voltage rises above the restart level. On over-voltage the load goes off at once and the alarm sounds intermittently until the problem is gone. Mode B, relay: the relay engages after 12 seconds of low voltage and releases when the load is switched off at 90 seconds; on over-voltage the load goes off at once and the alarm output stays inactive. In both modes, if the voltage recovers within the 90 seconds, for example because you started the engine or a charger, the load stays on.
Li-ion mode (C): only with a BMS that has a load disconnect output
Choose mode C only if your BMS has a load disconnect or charge disconnect output: a Victron smallBMS, VE.Bus BMS or the ATD/ATC contacts of a Lynx Smart BMS, for example. The BMS output goes to the Remote H terminal (a dry contact like ATD goes between L and H). The Smart BatteryProtect then ignores its own voltage thresholds and alarm output and does what the BMS says: the load goes off immediately when the BMS output switches from high to free floating, and stays off for at least 30 seconds. After three disconnect and reconnect attempts in a row it locks out (E7) until the battery has been above 13 V (26 V on 24 V, 52 V on 48 V) for 30 seconds, a sign that it is being charged. In mode C nothing else needs to be set.
Drop-in LiFePO4 with an internal BMS: mode A or B, with higher thresholds
Most LiFePO4 batteries with a built-in BMS have no output to control loads. For those Victron says mode A or B, never mode C. The Smart BatteryProtect then decides by battery voltage, and the factory 10.5 V is too low for LiFePO4: a 12 V LiFePO4 at 12.0 V has only about 10% left, the cells reach their absolute limit at 10.0 V, and the battery’s own BMS usually cuts out first, often around 11.2 V (2.80 V per cell). The aim is the opposite order: the Smart BatteryProtect switches off the non-essential loads first, and the BMS only steps in if something has gone wrong.
| Setting for a LiFePO4 drop-in | 12 V | 24 V | 48 V | Per cell |
|---|---|---|---|---|
| Preset 8 (a sensible start) | 12.0 V / 13.0 V | 24.0 V / 26.0 V | 48.0 V / 52.0 V | 3.00 V / 3.25 V |
| Preset 7 (a little more capacity) | 11.8 V / 12.8 V | 23.6 V / 25.6 V | 47.2 V / 51.2 V | 2.95 V / 3.20 V |
First figure: shutdown; second: restart. A shutdown of 11.8–12.0 V sits in the last 10% of the battery and safely above a typical BMS cut-off, while the 90-second delay rides through short voltage dips under heavy load. The restart sits at the resting voltage of a battery at about 20–40%: a LiFePO4 bounces back by a few tenths of a volt as soon as the loads are gone, and a restart level just above the shutdown would switch the loads on and off again and again. At 12.8–13.0 V the loads come back only once a charger is really working. Check your battery’s datasheet: the shutdown must stay above the BMS under-voltage cut-off. The full chart is in our LiFePO4 voltage chart, the other Victron devices in Victron LiFePO4 settings.
Smart BatteryProtect error codes
The Smart BatteryProtect has nine error codes, E0 to E8, and two warnings, P2 and P3. They appear on the 7-segment display and in VictronConnect; after 5 minutes the display goes dark to save current. There is no E9.
| Code | Meaning | What to do |
|---|---|---|
| E0 | Calibration failure | Internal fault you can’t fix: contact your dealer, the unit needs replacing. |
| E1 | Short circuit | A short circuit, an overload or too much inrush current, as from an inverter wired straight to OUT. The unit retries every 5 seconds and shows E1 after two attempts. Check for a short, check the load is within the rating, switch high-inrush loads through their remote on/off, look for loose or thin cables. |
| P2 | Over-temperature warning | The inside is close to its limit: reduce the load now, or E2 follows. |
| E2 | Over temperature | Check the load is within the rating and the connections are tight with the right cable size; move the unit away from heat or cool it. |
| P3 | Under-voltage warning | The load will be switched off in 90 seconds if nothing changes: reduce the load or start charging. |
| E3 | Under voltage | The voltage stayed below the shutdown level for 90 seconds. Switch off loads, recharge the battery, check that charging and battery work properly. |
| E4 | Over voltage | Above 16 V on 12 V, 32 V on 24 V, 64 V on 48 V. Check the system voltage and charge voltage of every charger, and that the Smart BatteryProtect has the right system voltage. |
| E5 | Configuration failure | Settings > More options > Reset to defaults in VictronConnect, disconnect all power for 3 minutes, then set it up again. |
| E6 | Reference voltage failure | Internal fault you can’t fix: contact your dealer, the unit needs replacing. |
| E7 | BMS lockout | The BMS asked for disconnect and reconnect three times in a row (Li-ion mode). It stays off until the battery is above 13 V (26 V, 52 V). Check the BMS log, recharge, check the wiring from BMS to the remote terminal. |
| E8 | Reverse current | Check the orientation: current only from IN to OUT. No charging source on the OUT side, and no loads on the IN side of a unit that switches a charger. |
Your Smart BatteryProtect on your iPhone with Deeck
Deeck reads the Smart BatteryProtect from your iPhone over Bluetooth, with no GX. Its page shows whether the output is on or off, the input and output voltage, a chart of both voltages, and the error code when there is one, so you can look it up in the table above. Like every Victron device, it’s free in Deeck. Its status in Deeck is Recognised: Deeck recognises it by its Victron protocol.
Deeck only reads it: switching the output on or off stays in VictronConnect or on the remote input. For the state of charge of the battery behind it, add a SmartShunt: Victron SmartShunt app.
Smart BatteryProtect, BatteryProtect, MultiPlus and VictronConnect are Victron Energy products; Deeck is independent and not affiliated with Victron. Figures and codes summarise Victron’s manuals and datasheets; for your unit, the manual has the final word.
Questions people ask
What is the difference between the Victron BatteryProtect and the Smart BatteryProtect?
Same currents (65, 100, 220 A), same delays (90 s to disconnect, 30 s to reconnect), same default thresholds and the same Li-ion mode. The Smart version adds Bluetooth: any shutdown and restart level in VictronConnect, Instant Readout in the device list, and the option to turn Bluetooth off. The older one has no Bluetooth: you pick one of its preset levels, shown on the 7-segment display.
Can I connect an inverter to a Victron BatteryProtect?
Not on its DC input. Victron forbids it: the inverter’s capacitors trip the short-circuit protection (E1) and a reverse current can damage the unit. Wire the inverter straight to the battery with its own fuse and let the Smart BatteryProtect switch it through the inverter’s remote on/off port.
What are good Smart BatteryProtect settings for LiFePO4?
For a drop-in battery with internal BMS: mode A or B and preset 8, 12.0 V shutdown and 13.0 V restart (24.0/26.0 V, 48.0/52.0 V), or preset 7 at 11.8/12.8 V. The shutdown must stay above your BMS under-voltage cut-off; your battery’s datasheet comes first.
Should I use Li-ion mode with a lithium battery?
Only if the BMS has a load disconnect or charge disconnect output, such as a smallBMS, VE.Bus BMS or Lynx Smart BMS. With a drop-in battery whose BMS is inside the case, Victron says mode A or B: in mode C the Smart BatteryProtect’s own voltage thresholds are inactive.
What does E1 mean on a Victron Smart BatteryProtect?
Short circuit: a real short, an overload above the unit’s rating, or a high inrush current, typically an inverter wired straight to the OUT terminal. The unit retries every 5 seconds and shows E1 after two attempts. Thin or loose cables can cause it too.
How long before the Smart BatteryProtect switches the loads off?
The alarm output switches on after 12 seconds below the shutdown level and the load goes off after 90 seconds. If the voltage recovers in the meantime, for example once the engine runs, the load stays on. It reconnects 30 seconds after the voltage rises above the restart level.