Victron MPPT settings for LiFePO4: the built-in preset and when to go custom
Victron MPPT settings for LiFePO4 start with one choice in VictronConnect: the built-in LiFePO4 preset or a user-defined one. The preset is Victron’s recommendation for lithium iron phosphate batteries; a user-defined preset is what you build when your battery maker’s datasheet asks for different voltages.
This guide lists what the SmartSolar MPPT preset does, setting by setting, with the 12, 24 and 48 V values from Victron’s manual, then explains absorption, float, re-bulk, tail current and the low-temperature cut-off, and how to set them so the SmartShunt agrees on when the battery is full.
What the LiFePO4 preset sets
Victron describes its LiFePO4 defaults in one paragraph of the SmartSolar manual: absorption 14.2 V, absorption time “fixed and set to 2 hours”, float 13.5 V, equalisation disabled, tail current 0 A “so that the full absorption time is available for cell balancing”, temperature compensation disabled. It then adds: “These settings are the recommended settings for LiFePO4 batteries, but they can be adjusted if the battery manufacturer specifications advise otherwise.”
| Setting | 12 V | 24 V | 48 V |
|---|---|---|---|
| Absorption voltage | 14.2 V | 28.4 V | 56.8 V |
| Absorption time | 2 h, fixed | 2 h, fixed | 2 h, fixed |
| Float voltage | 13.5 V | 27.0 V | 54.0 V |
| Re-bulk (restart of the charge cycle) | Below float − 0.1 V for 1 minute | Below float − 0.2 V for 1 minute | Below float − 0.4 V for 1 minute |
| Tail current | 0 A (off) | 0 A (off) | 0 A (off) |
| Equalisation | Not available | Not available | Not available |
| Temperature compensation | Off | Off | Off |
Sources: SmartSolar MPPT 100/30 & 100/50 manual, Operation (12 and 24 V) and SmartSolar MPPT 150/35 & 150/45 manual, Operation (48 V). The re-bulk rule is given for 12 V and multiplied by two for 24 V and by four for 48 V.
One inconsistency, so you are not surprised: the same manuals’ short “Lithium batteries” chapter lists a float of 13.2 V (26.4 V, 52.8 V), while the rotary-switch table and the LiFePO4 defaults paragraph give 13.5 V. Open the LiFePO4 preset in VictronConnect to see what your firmware uses, and set the float your battery’s datasheet asks for.
The smaller SmartSolar models, 75/10 up to 100/20 (so the 75/15 and the 100/20 too), list the same LiFePO4 defaults in their own manual: 14.2 V absorption for a fixed 2 hours, 13.5 V float, tail current 0 A. On these models you select the preset and change values in the VictronConnect app (SmartSolar MPPT 75/10 up to 100/20 manual, Operation).
Preset or user-defined?
In VictronConnect, Settings › Battery › Battery preset offers the rotary switch position (on models that have one, LiFePO4 is position 7), the factory presets, and your own presets. Victron’s instructions for a custom profile are short (MPPT manual, Configuration and settings):
- 1
Select the factory preset closest to your battery: for a LiFePO4 drop-in, the LiFePO4 preset.
- 2
Change the values your datasheet specifies. The preset becomes “User defined”.
- 3
For re-bulk, absorption duration and tail current, switch on Expert mode; Victron advises doing that only if your equipment has special requirements.
- 4
Save it with Create preset and a name. It is stored in VictronConnect’s library, so a second MPPT gets the same profile in two taps.
Factory presets can’t be edited, only your own. Victron’s caution is worth repeating: a wrongly defined charge algorithm can damage the battery or create unsafe situations.
Batteries that talk to a GX device over CAN-bus are a different case: the battery tells the solar charger what voltage to use, and the MPPT’s own algorithm no longer applies.
The settings one by one
Absorption
The constant-voltage stage at the top of the charge. For lead-acid the MPPT adapts the absorption time each morning from the battery voltage, up to 6 hours by default. For LiFePO4 the preset uses a fixed 2 hours. In a custom profile the maximum absorption time can be set up to 12 h 59 min. The absorption timer pauses when clouds pull the voltage below the absorption voltage, and the whole algorithm resets if charging stops for an hour.
Float
The lower voltage held after absorption. For LiFePO4 your datasheet decides; some makers want a low float, some none at all. Victron’s preset uses 13.5 V on 12 V; a user-defined preset lets you set the value your datasheet gives.
Re-bulk voltage offset
When the battery voltage drops below float minus this offset for one minute, the charge cycle starts again from bulk. LiFePO4 holds a flat voltage, which is why the preset uses a small 0.1 V offset (12 V) where lead-acid uses 0.4 V.
Tail current
In expert mode, the current below which absorption ends early (after one minute) and float begins. The general default is 2 A; the LiFePO4 preset sets 0 A, which switches it off, so absorption always runs its full 2 hours for cell balancing. If you enable it, the MPPT compares it with its own output current, or with the real battery current when a SmartShunt shares it over VE.Smart networking. More in Victron tail current explained.
Low-temperature cut-off
Stops charging when the battery is too cold. It is off by default; when enabled, the default is 5 °C, which Victron calls “a suitable temperature setting for lithium iron phosphate (LFP) batteries”, adding that you should always check with the battery supplier. Charging resumes 0.5 °C above the setting. It only works when the MPPT receives a battery temperature through a VE.Smart network, from a Smart Battery Sense or a battery monitor with a temperature sensor, and it isn’t needed for batteries that block charging in the cold by themselves.
12, 24 and 48 V: what changes
- Voltages scale. Victron writes its MPPT values for 12 V and multiplies them by two for 24 V and by four for 48 V, as in the table above.
- Which voltages your model supports. The 100/30 and 100/50 handle 12 and 24 V. The 150/35 and 150/45 also handle 36 and 48 V.
- Automatic detection. The MPPT detects the battery voltage at its very first power-up and then stops detecting. A 36 V battery is not detected and must be set by hand (150/35 manual). After a battery change, check the system voltage in VictronConnect.
The cables matter as much as the settings: with a thin cable between the MPPT and the battery, part of the absorption voltage is lost on the way, and at 12 V the same power means twice the current of 24 V. The cable size calculator gives the size in mm² and AWG for 12, 24 and 48 V; for the charger-to-battery run, aim for a drop of 1–2 %.
Matching the MPPT with the SmartShunt
With the preset, the MPPT absorbs at 14.2 V for two hours and the SmartShunt’s LiFePO4 charged voltage is 13.9 V: the voltage condition is met throughout absorption, while the current tapers off. When it falls below the SmartShunt’s tail current for the detection time, the SmartShunt synchronises to 100 %. If you lower the absorption voltage in a custom preset, lower the SmartShunt’s charged voltage too, or it will never synchronise. The SmartShunt side is covered in SmartShunt LiFePO4 settings.
Settings depend on your battery and its BMS. Follow the maker’s specifications for absorption, float, maximum charge current and minimum charging temperature.
What Deeck shows
VictronConnect sets up the MPPT; what Deeck adds is the view over days: solar power and yield next to the SmartShunt’s state of charge, the solar forecast with Deeck Plus, and an estimate in days and hours of how long the battery lasts. A battery that reaches 100 % every sunny afternoon tells you the preset and the SmartShunt agree. On iPhone for free; on CarPlay and Apple Watch with Deeck Plus: see SmartShunt on iPhone and Victron on CarPlay.
Questions people ask
Which Victron MPPT preset for LiFePO4?
The built-in LiFePO4 preset: 14.2 V absorption for a fixed 2 hours and 13.5 V float on 12 V. Use a user-defined preset only if your battery’s datasheet asks for other values.
What absorption voltage for LiFePO4 on a 24 V or 48 V system?
Victron’s preset uses 28.4 V for 24 V and 56.8 V for 48 V. Your battery maker’s datasheet has the final word.
Why is tail current 0 A in the LiFePO4 preset?
Victron sets it to 0 A so the full absorption time is available for cell balancing. With 0 A, absorption ends on time, not on current.
Should I set a low-temperature cut-off on my MPPT?
Only if your battery cannot block cold charging itself. Victron’s default is 5 °C when enabled; it needs a battery temperature reading over VE.Smart networking to work.
What float voltage for LiFePO4 on a Victron MPPT?
The LiFePO4 preset uses 13.5 V on 12 V (27.0 V on 24 V, 54.0 V on 48 V). If your battery maker recommends a different float, set it in a user-defined preset.
Are the LiFePO4 settings the same on a SmartSolar 75/15 or 100/20?
Yes. Victron’s manual for the 75/10 up to 100/20 lists the same LiFePO4 defaults: 14.2 V absorption for a fixed 2 hours and 13.5 V float on 12 V. You select the preset and change values in the VictronConnect app.