Victron Cyrix: how the split charge relay works, how to wire it, and when lithium needs a DC-DC charger

The Victron Cyrix is a voltage sensitive relay, also called a split charge relay or battery combiner: it connects your starter battery and your service battery in parallel when one of them is being charged, and separates them again when the voltage drops, so the starter battery stays ready for the engine. The Cyrix-ct engages from 13.0 V (after about 10 minutes) to 13.8 V (after about 4 seconds) and disengages between 12.8 V and 11 V, the lower the voltage the faster; double the figures on 24 V. It comes as Cyrix-ct 120 A and 230 A, Cyrix-i 400 A, and as Cyrix-Li-ct, Cyrix-Li-Charge and Cyrix-Li-load for lithium systems whose BMS sends a control signal. With a drop-in LiFePO4 battery or a Euro 5/6 smart alternator, a DC-DC charger is the device built for the job.

Below: every model, the full engage and disengage tables, wiring with fuses and ground, the lithium versions and when to switch to a DC-DC charger, a comparison with a classic ignition relay, and what to check when the Cyrix won’t engage or keeps clicking. Figures come from Victron’s datasheets Cyrix-ct 120 A and 230 A, Cyrix-i 400 A, Cyrix Li-ion 120 A and 230 A, the Cyrix manuals and Victron’s note Sizing a Cyrix battery combiner.

What a Victron Cyrix does, and which model you need

In a typical van or motorhome the alternator charges the starter battery directly. The Cyrix sits between the starter battery and the service battery. When it sees the starter battery reach its connect voltage, it closes and both batteries charge in parallel. When the engine stops and the voltage falls, it opens again, and your fridge or lights can only drain the service battery. Because it is a relay and not a diode isolator, there is virtually no voltage loss, so the alternator voltage doesn’t need to be raised.

ModelSystemContinuous currentPeak currentWhat it is for
Cyrix-ct 12/24-12012 or 24 V, auto ranging120 A180 A for 5 sStarter + service battery, no LED
Cyrix-ct 12/24-23012 or 24 V, auto ranging230 A500 A for 5 sSame job, LED, 1 m control cable
Cyrix-i 12/24-400 and 24/48-40012/24 V or 24/48 V400 A2000 A for 1 sLarge banks, 4 switch profiles, bicolour LED
Cyrix-Li-ct 12/24-120 and -23012 or 24 V120 A or 230 A–Lead-acid starter + LiFePO4 with a BMS signal
Cyrix-Li-Charge 120 and 23012/24 V or 24/48 V120 A or 230 A–Switches a charger, controlled by the BMS
Cyrix-Li-load 120 and 23012/24 V or 24/48 V120 A or 230 A–Switches loads, controlled by the BMS

The 120 A Cyrix-ct has 13 mm (M6) bolts, the 230 A version 16 mm (M8), long enough to stack more than one cable. Both draw less than 4 mA when open; when closed the 120 A draws 220 mA on 12 V (120 mA on 24 V) and the 230 A 320 mA (180 mA on 24 V). Both are IP54 and work from −40 to +60 °C. The current Cyrix-ct 120 manual also lists a 24/48 V version. For the Li models at 48 V, the breaking capacity drops to 40 A (120 A models) and 80 A (230 A models).

Trend detection instead of a fixed timer

Simple voltage sensitive relays drop out when a short heavy load pulls the voltage down, and some never manage to connect a large discharged bank because the voltage sinks below the disengage level the moment they close. The Cyrix-ct and Cyrix-i look at the trend, rising or falling, and only reverse an action when the trend has reversed for a certain time. The delay depends on how far the voltage is from the trend.

Cyrix-ct engage and disengage voltages

These are the approximate delays from Victron’s datasheet for the Cyrix-ct 120 A and 230 A. On 24 V, multiply every voltage by two. The Cyrix-ct detects 12 or 24 V by itself.

Voltage on either battery (12 V)24 VCyrix-ct engages
below 13.0 Vbelow 26.0 Vstays open
13.0–13.2 V26.0–26.4 Vafter about 10 min
13.2–13.4 V26.4–26.8 Vafter about 5 min
13.4–13.6 V26.8–27.2 Vafter about 1 min
13.6–13.8 V27.2–27.6 Vafter about 4 s
Voltage (12 V)24 VCyrix-ct disengages
above 12.8 Vabove 25.6 Vstays closed
12.4–12.8 V24.8–25.6 Vafter about 3 min
12.2–12.4 V24.4–24.8 Vafter about 30 s
12.0–12.2 V24.0–24.4 Vafter about 10 s
11.0–12.0 V22.0–24.0 Vafter about 1 s
below 11.0 Vbelow 22.0 Vimmediately
above 16 Vabove 32 Vover-voltage disconnect
  • Both directions: the Cyrix measures both batteries, so it also engages when a mains charger or a solar charger lifts the service battery. Your starter battery gets charged too.
  • Dual power supply: it is powered from both sides, so it still closes when one battery is too low to run it.
  • Safety lockout: it won’t close if one of the two battery terminals is below 2 V (4 V on 24 V), to avoid surprises during installation or with a battery disconnected.
  • Over temperature: after a long overload the contacts heat up; the Cyrix opens and engages again once it has cooled down.
  • Start Assist: a push button that briefly connects the start assist terminal to battery plus closes the relay for 30 seconds, to start the engine from the service battery when the starter battery is flat or damaged. A switch instead of a push button keeps it closed for as long as the switch is on.

Cyrix-i 400 A: four switch profiles

The Cyrix-i has a profile selector under its cover. Profile 0 (default) works in steps like the Cyrix-ct: it engages after about 10 minutes at 13.0 V down to 4 seconds at 13.8 V, and disengages from 10 minutes at 12.8 V to immediately below 11 V. Profile 1 engages above 13.25 V after 30 seconds and disengages between 10.5 and 12.75 V after 2 minutes. Profile 2 engages above 13.2 V after 6 seconds and disengages between 10.5 and 12.8 V after 30 seconds. Profile 3 is slow to let go: it stays closed above 13.5 V and opens after up to 30 minutes at 12.8 V. In every profile it opens immediately below 10.5 V (below 11 V in profile 0). After three connections the minimum time to reconnect is 1 minute, to prevent rattling. Multiply by two for 24 V and by four for 48 V. A bicolour LED shows red (open), red/green (timer running) or green (closed), and a micro switch reports the contact state to a remote panel.

How to wire a Victron Cyrix

  1. 1

    Check the system: the Cyrix only works in installations with a common negative, where both batteries share the same minus.

  2. 2

    Disconnect the minus of both batteries before you start.

  3. 3

    Position: close to the smaller battery, usually the starter battery, on a dry surface away from hot parts. Victron places it there to reduce the effect of voltage drop along the cables.

  4. 4

    Plus cables: starter battery plus to one brass bolt, service battery plus to the other (marked 30 and 87 on the 120 A model). Put a fuse in series, sized to the cable cross section and never above 120 A, 230 A or 400 A depending on the model. The Cyrix-ct 120 kit comes with 10 mm² red cable for these runs.

  5. 5

    Ground: connect the Cyrix “battery –” terminal (86 on the 120 A model) to the common negative. In the kit this is a 1.5 mm² black wire. Without it the Cyrix can’t work.

  6. 6

    Start Assist (optional): wire a push button between battery plus and the start assist terminal (85 on the 120 A model). The 230 A model has a 1 m control cable included.

  7. 7

    Reconnect the minus of both batteries. The Cyrix is ready.

Which current rating you need

When a discharged battery is connected to a full one, Victron measured only a short current spike: the voltage quickly settles at about 12.75 V and the current drops to nearly zero. So a Cyrix can connect batteries with up to five times its current rating in amp-hours: a 200 A Cyrix can handle up to 1000 Ah. But the rating must never be lower than the continuous current that can flow from one battery to the other. Example from Victron: a 200 A alternator on the starter battery and a 100 A charger on the house battery call for a 200 A Cyrix; if both feed the same battery, at least 300 A. The Cyrix-ct 120 kit lists a maximum alternator rating of 150 A.

Cyrix with a lithium service battery: Cyrix-Li-ct or a DC-DC charger

The plain Cyrix-ct decides only by voltage and stays closed above 12.8 V. Victron notes that a LiFePO4 battery with little or no discharge current stays above 13.5 V after charging. Because the Cyrix senses both sides, a charged lithium bank can keep it closed with the engine off, and nothing stops the charge current when the cells are full or cold. That is why Victron makes separate lithium versions controlled by the BMS.

Cyrix-Li-ct: lead-acid starter battery and LiFePO4 with a BMS

The Cyrix-Li-ct connects a lead-acid starter battery and a LiFePO4 battery when two conditions are met: the BMS charge disconnect output is high (Victron’s datasheet describes it with the VE.Bus BMS), and it sees 13.4 V (26.8 V) or more on one of its terminals. It engages after 120 s between 13.4 and 13.7 V, 30 s between 13.7 and 13.9 V and 4 s above 13.9 V (26.8, 27.4 and 27.8 V on 24 V). It disengages immediately when the voltage drops below 13.2 V (26.4 V) or when the BMS control signal goes free floating because of cell over-voltage or over-temperature. A built-in transient voltage suppressor limits the spike of that sudden opening. Start assist works with a short negative pulse, which closes the relay for 30 seconds.

Cyrix-Li-Charge and Cyrix-Li-load

The Cyrix-Li-Charge connects a charger to the battery after 3 seconds if the BMS charge disconnect output is high, it sees 13.0 V (26.0 V, 52.0 V) or more on the charger side and at least 2 V on the battery side. It opens immediately when the control input goes free floating and, once engaged, opens after 1 hour to check that the charger is still active. The Cyrix-Li-load disengages when its control input goes free floating, reconnects after 30 seconds when the BMS output goes high again, and after three attempts stays open until the battery has been above 13 V (26 V, 52 V) for at least 30 seconds. For loads Victron also points to a BatteryProtect, which draws much less current: see our Smart BatteryProtect guide.

When a DC-DC charger is the better choice

  • Drop-in LiFePO4 with the BMS inside the case: it has no charge disconnect output to drive a Cyrix-Li-ct. A DC-DC charger charges it with a proper lithium profile and a current limit.
  • Euro 5 or Euro 6 smart alternator: Victron writes that these often supply too low a charging voltage even with the engine running. A Cyrix that needs 13 V or more then engages late or not at all. Victron designs the Orion XS and Orion-Tr Smart for these alternators, with engine running detection.
  • Long cable runs between front and rear, common in motorhomes and boats, cause voltage drop that a DC-DC charger compensates for.
  • You want to protect the starter battery: the Orion XS shuts down below a configurable input voltage and restarts above the restart value.

How to choose and size one: DC-DC charger guide. The Victron Orion XS on your iPhone: Victron Orion XS app.

Cyrix, classic split charge relay or DC-DC charger

Victron Cyrix-ctClassic relay on ignition or D+DC-DC charger (e.g. Orion XS)
What switches itVoltage on either battery, with trend detectionAn ignition or D+ signal wireEngine running detection or a remote input
Signal wire neededNo: two plus cables and a thin groundYesOptional
Voltage lossVirtually noneVirtually noneNone: it regulates its output
Charge profile for the service batteryWhatever the alternator givesWhatever the alternator givesIts own multi-stage profile, adjustable current
Charges the starter battery from a mains or solar chargerYes, it engages in both directionsNo, only with the engine onNot by default; the Orion XS can do it with reverse charging
Euro 5/6 smart alternatorMay engage late or not at allConnects, but the voltage may be too lowDesigned for it
Drop-in LiFePO4Cyrix-ct no; the Cyrix-Li-ct needs a BMS signalNo charge control for lithiumYes, with a lithium profile
Own consumptionUnder 4 mA open, 120–320 mA closedDepends on the relayDepends on the model

With a lead-acid or AGM service battery, a classic alternator and short cables, a Cyrix-ct does the job with simple wiring and no signal wire, and it charges the starter battery when you’re on shore power. As soon as lithium or a smart alternator comes in, the DC-DC charger is the safer route.

Cyrix problems: won’t engage, keeps clicking, LED codes

The Cyrix won’t engage

  • The voltage never reaches 13 V: check with a meter at both bolts with the engine running. A smart alternator, a weak alternator or a long thin cable keeps the voltage below the connect threshold.
  • One side below 2 V (4 V on 24 V): a blown fuse or a loose plus cable looks like a missing battery, and the Cyrix stays open on purpose.
  • No ground: the “battery –” terminal must be connected to the common negative.
  • Over temperature or over-voltage: above 16 V (32 V) or after a long overload it opens and waits.
  • Cyrix-Li-ct: it also needs the BMS charge disconnect output high, and 13.4 V (26.8 V) instead of 13.0 V.

It engages and disengages again and again

When it closes onto a deeply discharged bank, the voltage drops and the Cyrix may open again. Trend detection is there to prevent this, but undersized cables, a Cyrix far from the starter battery or large loads running while you drive can still push the voltage across the thresholds. Check the cable cross section and connections, mount the Cyrix near the smaller battery and match the rating to the alternator. On a Cyrix-i, choose a profile with a slower disengage (profile 3) or a fixed delay (profiles 1 and 2). If it stays closed with the engine off, look for a charger or solar panel on either battery: in both directions that is normal behaviour, and a lithium bank above 12.8 V will hold a Cyrix-ct closed too.

LED codes of the Cyrix-ct 230 and Cyrix-Li 230

LEDMeaning
OnEngaged
10 s flashDisengaged
2 s flashConnecting
2 s blinkDisconnecting
0.25 s blinkAlarm: over temperature, voltage above 16 V (32 V), both batteries below 10 V (20 V), or one battery below 2 V (4 V)

The 120 A Cyrix-ct has no LED: check it with a voltmeter on both bolts. When it is engaged, both read the same apart from cable losses.

Your two batteries on your iPhone with Deeck

The Cyrix has no Bluetooth and no data port, so Deeck can’t read it and its engaged or open state doesn’t show up in any app. What you can see is the result: both batteries. If your SmartShunt or BMV has its auxiliary input on the starter battery, Deeck shows a Starter battery page with its voltage and state, free over Bluetooth. The service battery is the one your SmartShunt or BMV measures. Watching both voltages side by side while you drive or charge tells you a lot about how your split charging is doing. Setup: Victron SmartShunt app.

If you move to an Orion XS, Deeck reads it from your iPhone, no GX needed and free: power, input and output voltage and current, charging stage and charts. From the app you can also charge the starter battery from the service battery, the emergency charge free and the full charge with Deeck Plus: Orion XS starter battery charge.

Cyrix, Orion, SmartShunt, BMV and BatteryProtect are Victron Energy products; Deeck is independent and not affiliated with Victron. Figures summarise Victron’s datasheets and manuals; for your unit, the manual has the final word.

Questions people ask

At what voltage does a Victron Cyrix engage?

The Cyrix-ct engages from 13.0 V after about 10 minutes, 13.2 V after 5 minutes, 13.4 V after 1 minute and 13.6–13.8 V after about 4 seconds. Below 13.0 V it stays open. On 24 V, double the figures.

At what voltage does the Cyrix disengage?

Above 12.8 V it stays closed. Between 12.4 and 12.8 V it opens after about 3 minutes, between 12.0 and 12.4 V within 30 seconds, below 12 V within 1 second and below 11 V immediately. Above 16 V it opens for over-voltage. Double for 24 V.

Can I use a Victron Cyrix-ct with a LiFePO4 battery?

Victron makes the Cyrix-Li-ct for that: it connects a lead-acid starter battery and a LiFePO4 battery only when the BMS charge disconnect output allows it, and opens below 13.2 V. With a drop-in LiFePO4 whose BMS has no such output, use a DC-DC charger such as the Orion XS.

Does the Cyrix charge the starter battery from a mains or solar charger?

Yes. The Cyrix senses both batteries, so it also engages when a charger lifts the service battery above the connect voltage, and the starter battery charges with it.

What is Start Assist on the Cyrix?

A push button between battery plus and the start assist terminal closes the relay for 30 seconds, so you can start the engine with help from the service battery. A switch keeps it closed as long as it is on. On the Cyrix-Li-ct it takes a short negative pulse.

Which Cyrix size do I need?

At least the largest continuous current that can flow between the batteries, such as your alternator output. Victron’s rule: a Cyrix can connect batteries up to five times its current rating in Ah, so 120 A suits up to 600 Ah.

On the dash and on your wrist

Both batteries, on your iPhone.

Seeing it is free. Having it on the dash and on your wrist is Deeck Plus.

Put it on CarPlay and Watch Download the app free

Free app · Deeck Plus €39.99 a year · cancel anytime · 14 days to change your mind