DC-DC charger in a campervan, motorhome or boat: what it does, what size you need and how to wire it
A DC-DC charger, also called a B2B (battery-to-battery) charger, sits between the starter battery and the house battery and charges the house battery from the alternator while you drive, with a proper charge profile. You need one when your vehicle has a Euro 6 smart alternator, when the house battery is LiFePO4, or when the cable run is long: in each case a plain split charge relay leaves the house battery undercharged or lets it overload the alternator. The size, for example 30 A or 50 A, follows from your battery’s maximum charge current and from what your alternator can spare.
Below: the difference with a relay, how to choose the current, isolated or non-isolated, how the charger knows the engine is running, the LiFePO4 settings, cable and fuse sizes, and the Victron Orion XS and Orion-Tr Smart models. Figures come from Victron’s Orion XS datasheet, the Orion XS manual and the Orion-Tr Smart datasheets (isolated, non-isolated).
What a DC-DC charger does, and why you need one
Without one, the house battery is charged straight from the alternator through a relay: it gets whatever voltage the alternator puts out, minus what the cable loses on the way. A DC-DC charger takes that voltage, whatever it is, and turns it into the charge curve your house battery needs: bulk, absorption, float. It also keeps the two batteries separate, so the house loads never flatten the starter battery.
- Euro 6 smart alternator. Victron notes that vehicles with a Euro 5 or Euro 6 smart alternator often supply too low a charge voltage even with the engine running. On a 12 V system it can swing between about 12.5 and 15 V, and the alternator can switch off for a while during the drive. A DC-DC charger brings the voltage back up to the charge voltage.
- LiFePO4 house battery. Lithium has a low internal resistance and takes as much current as the alternator gives. Victron puts it plainly: controlled charging protects the alternator in lithium systems from overloading. With a DC-DC charger you set the current yourself.
- Long cables. In a motorhome or a boat the house battery can sit several metres from the engine. Victron’s own example: 5 m of 16 mm² cable at 50 A loses about 0.55 V. The charger regulates its output, so the battery still gets the right voltage.
DC-DC charger or split charge relay
A split charge relay, or voltage-sensitive relay (VSR), such as the Victron Cyrix connects the two batteries in parallel when it sees a charging voltage and separates them when the voltage drops. It is simple and has no charge profile: the house battery sees the alternator voltage as it is. How it works and how to wire it: Victron Cyrix.
| Split charge relay (e.g. Cyrix) | DC-DC charger (e.g. Orion XS) | |
|---|---|---|
| What reaches the house battery | The alternator voltage, minus the cable drop | A full charge curve: bulk, absorption, float |
| Euro 6 smart alternator | Low or switched-off alternator: the house battery stays undercharged | Raises the voltage; start and shutdown thresholds you can adjust |
| LiFePO4 house battery | Current limited only by cable and alternator | Input and output current limits you set |
| Long cable | The voltage drop reaches the battery | Output voltage regulated at the charger |
| Settings and monitoring | None on the Cyrix: no Bluetooth, no data port | Bluetooth with VictronConnect; the Orion XS also has VE.Direct |
A relay still does the job with a lead-acid house battery and a conventional alternator that holds a steady voltage. Euro 6 van, lithium battery or long cables: take a DC-DC charger.
What size DC-DC charger do I need?
Three things decide it: what your house battery accepts, what your alternator can spare, and how long you drive.
- 1
The battery’s maximum charge current. It’s in your battery’s datasheet. The charger’s output current must stay within it.
- 2
What the alternator can spare. The vehicle uses part of the alternator for itself. And a DC-DC charger draws more current at its input than it delivers at its output whenever the starter side sits below the house battery voltage: power in equals power out plus losses. Victron gives the Orion XS an input current limit precisely to avoid overloading an alternator.
- 3
How long you drive. As a rough guide, the hours needed are the amp-hours to put back divided by the charge current: 100 Ah takes about 2 hours at 50 A and a little over 3 hours at 30 A, before the absorption phase.
30 A or 50 A?
At 14 V, 30 A is about 420 W and 50 A is 700 W. With a modest alternator or a battery that accepts little current, 30 A keeps everything relaxed. With a large lithium bank and an alternator with headroom, 50 A recharges it faster. The Orion XS 12/12-50A adjusts both input and output current from 1 to 50 A in 0.1 A steps, so you can start at 30 A and raise it later. For more there is the Orion XS 12/12-70A, or several units in parallel: Victron allows an unlimited number.
Isolated or non-isolated
A non-isolated DC-DC charger shares the negative between input and output. In most vans and motorhomes the starter and house batteries already share the chassis as negative, so a non-isolated charger is the usual choice.
An isolated charger has galvanic isolation between input, output and case: 200 VDC on the Orion-Tr Smart isolated, which Victron says allows the input and output to have separate chassis grounds. You need it when the two circuits must keep separate negatives, for example on a boat where the house circuit is kept apart from the engine’s, or when you want another output voltage such as 12 to 48 V: only the isolated Orion-Tr Smart has 48 V output versions. On an isolated unit the remote and engine-running signals must come from the input (starter) side.
The Orion XS datasheet lists no galvanic isolation; the Orion-Tr Smart comes in both versions.
How the charger knows the engine is running
The charger must only draw from the starter battery while the alternator is supplying power. There are three ways to tell it.
Voltage detection (engine shutdown detection)
The Orion XS and the Orion-Tr Smart read the voltage at their input, with no extra wiring. Charging starts when the voltage rises above the start level and stops when it stays below the shutdown level for one minute, so short dips don’t interrupt it. In VictronConnect you choose smart or regular alternator; smart is the default.
| Setting (12 V / 24 V) | Smart alternator (default) | Regular alternator |
|---|---|---|
| Start voltage: charging starts at once | 14 V / 28 V | 14 V / 28 V |
| Delayed start voltage | 13.3 V / 26.6 V | 13.8 V / 27.6 V |
| Delay at that voltage | 120 s | 120 s |
| Shutdown voltage: engine considered off | 13.1 V / 26.2 V | 13.5 V / 27 V |
On a Euro 6 vehicle the smart alternator can switch off while you drive: the starter battery falls back to its resting voltage, around 12.6 V, and the charger can conclude the engine has stopped. When enough loads are on, the alternator holds at least about 13.8 V and detection works. Victron notes results vary from vehicle to vehicle, even within the same model; lowering the start and shutdown voltages helps, at the cost of a smaller margin.
D+, ignition or an engine-running signal
- D+: the alternator’s running signal. Victron notes that Euro 6 vehicles often no longer provide it. D+ simulators work from the same alternator voltage the charger already measures, so they add nothing where that voltage is the problem.
- Ignition: common, but Victron doesn’t recommend it: with the ignition on and the engine off, the charger drains the starter battery.
- Engine-running signal from the vehicle: the most accurate source, wired to the remote L-pin. More than 8 V on the Orion XS (7 V on the Orion-Tr Smart) forces charging on. Keep voltage detection enabled: it is still what stops charging when the engine is off.
Input voltage lock-out
The last guard for the starter battery: below the lock-out voltage, charging stops at once. Orion XS default in charger mode: lock-out 12.5 V, restart 12.8 V (25 V and 25.6 V on 24 V). Victron’s rule: lock-out ≤ shutdown voltage minus the voltage drop in the input cable; the manual’s example gives 13.1 V − 0.55 V = 12.55 V.
DC-DC charger settings for LiFePO4
Pick a lithium preset or build your own from the battery’s datasheet. The Orion XS has eight pre-programmed battery settings and a four-stage algorithm; the Orion-Tr Smart charges in three stages: bulk, absorption, float. For lithium the absorption time is fixed, 2 hours by default. Keep the output current within the battery’s maximum charge current and set the input current with the alternator in mind. On the Orion XS, the low-temperature cut-off for lithium works when a SmartShunt or BMV-712 shares the battery temperature over VE.Smart.
Every setting, step by step: Orion XS LiFePO4 settings. Voltage against state of charge: LiFePO4 voltage chart.
Wiring and cable size
- 1
Position: a dry, ventilated spot, never on top of the battery, and away from engine heat: above 40 °C the output is reduced (1.5% per °C on the Orion XS, 3% per °C on the Orion-Tr Smart). The Orion XS 12/12-50A and 1400 are IP65; the 12/12-70A is IP20, for dry indoor spaces only.
- 2
Input: starter battery positive, with a fuse at the battery.
- 3
Output: house battery positive, with its own fuse at that battery.
- 4
Negatives: on a non-isolated unit to the common negative; on an isolated unit each side to its own battery.
- 5
Remote: the wire loop fitted on delivery switches the charger on. A switch, a BMS allowed-to-charge output or an engine-running signal can go here instead.
- 6
Cable: flexible multi-strand copper, with at least the cross-section below.
| Model | Battery fuse | Minimum cable, short run | Minimum cable, long run |
|---|---|---|---|
| Orion XS 12/12-50A and 1400 | 60–70 A | 16 mm² (under 5 m) | 4 AWG, 21.2 mm² (5–10 m) |
| Orion XS 12/12-70A | 80–100 A | 25 mm² (under 10 m) | – |
| Orion-Tr Smart, 12 V side | 60 A | 6 mm² (0.5 m), 10 mm² (1–2 m) | 16 mm² (5–10 m) |
| Orion-Tr Smart, 24 V side | 30 A | 4 mm² (0.5 m), 6 mm² (1–2 m) | 10 mm² (5–10 m) |
| Orion-Tr Smart, 48 V side | 20 A | 2.5 mm² (0.5 m), 4 mm² (1–2 m) | 6 mm² (5–10 m) |
These are Victron’s minimums. For your own length and current, the 12 V cable size calculator gives the cross-section for the voltage drop you accept. The terminals take up to 21.2 mm² (4 AWG) on the Orion XS 50 A and 1400, 25 mm² on the 70 A and 16 mm² on the Orion-Tr Smart.
Victron DC-DC chargers: Orion XS and Orion-Tr Smart
| Range | Models | Power | Notes |
|---|---|---|---|
| Orion XS | 12/12-50A, 12/12-70A, 1400 (12 and 24 V, 1–50 A) | 700 W, 1000 W, 1400 W | Current adjustable from 1 A; IP65 (70 A: IP20); VE.Direct |
| Orion-Tr Smart non-isolated | 12/12-30, 12/24-15, 24/12-30, 24/24-17 | 360–400 W | No VE.Direct |
| Orion-Tr Smart isolated | 12/12-30, 12/24-15, 12/48-8, 24/12-30, 24/24-17, 24/48-8.5, 48/12-30, 48/24-16, 48/48-8; also 12/12-18, 12/24-10, 24/12-20, 24/24-12, 48/12-20 | 220–400 W | 200 VDC galvanic isolation; no VE.Direct |
The Orion-Tr names read input voltage / output voltage – continuous current at 40 °C: a 12/12-30 takes 12 V and delivers 30 A at 12 V. The Orion XS power figures are at 14 V (50 A), 14.3 V (70 A) and 28 V (1400). Every model has Bluetooth with Instant Readout and can be paralleled without limit. Victron notes that VictronConnect doesn’t show the Orion-Tr Smart’s input and output current. The Orion XS adds a four-stage algorithm, VE.Direct for a GX, VRM and DVCC, and the emergency reverse charge of the starter battery from the house battery.
Your DC-DC charger on your iPhone with Deeck
Deeck reads the Orion XS from your iPhone over Bluetooth, with no GX and for free. You see the power, the input voltage and current from the starter side, the output voltage and current into the house battery, the state (bulk, absorption, float, off, reverse charge), the reason when it is off, and charts of power, voltages and currents. If the Orion reports an error, you see it with its code on the device page. The Orion’s temperature shows up with Deeck Bridge.
One command from the iPhone: charging the starter battery from the house battery. The emergency charge is free; the full charge is part of Deeck Plus: Orion XS: charge the starter battery. Switching the Orion on or off and changing its current stay in VictronConnect.
The Orion-Tr Smart, isolated and non-isolated, is free in Deeck too, with the status Recognised: Deeck recognises it and shows its state and voltages in the charts; an error shows with its code on the device page.
A Cyrix has no Bluetooth or data port, so Deeck can’t show whether it is engaged. You still see both batteries if your system measures them: a SmartShunt or BMV with its auxiliary input on the starter battery gives the “Starter battery” page with voltage and state, for free, and the house battery is the one the SmartShunt or BMV measures (Victron SmartShunt app).
The app is free, and reading your Victron devices nearby over Bluetooth costs nothing. Deeck Plus, an annual subscription at €39.99 a year, adds CarPlay, Apple Watch and remote access through Deeck Bridge.
Orion XS, Orion-Tr Smart, Cyrix, SmartShunt, BMV and VictronConnect are Victron Energy products; Deeck is independent and not affiliated with Victron. Figures summarise Victron’s datasheets and manuals; for your unit, the manual has the final word.
Questions people ask
What does a DC-DC charger do in a campervan?
It charges the house battery from the alternator while you drive, with a proper charge curve (bulk, absorption, float), and keeps the starter battery separate. It raises a low alternator voltage, limits the current a lithium battery would pull, and compensates for long cables.
What size DC-DC charger do I need?
Start from your battery’s maximum charge current, then check what your alternator can spare. At 14 V, 30 A is about 420 W and 50 A is 700 W. Roughly, 100 Ah takes about 2 hours at 50 A and a little over 3 hours at 30 A. An adjustable charger like the Orion XS 12/12-50A lets you start lower and raise the current later.
Do I need a DC-DC charger with a lithium battery?
Yes, in practice. LiFePO4 has a low internal resistance and takes as much current as the alternator gives; Victron notes that controlled charging protects the alternator in lithium systems from overloading. A DC-DC charger also gives the battery its lithium charge curve.
Do I need a DC-DC charger with a Euro 6 smart alternator?
Usually yes. A smart alternator varies its voltage, roughly between 12.5 and 15 V on 12 V, and can switch off during the drive. A relay passes that low voltage on to the house battery; a DC-DC charger raises it to the charge voltage.
What is a B2B charger?
Battery-to-battery charger: another name for a DC-DC charger. It takes power from the starter battery side and charges the house battery with its own charge profile.
Isolated or non-isolated DC-DC charger?
Non-isolated when both batteries share the negative, as in most vans and motorhomes. Isolated when input and output must keep separate negatives, for example on some boats, or when you need a 48 V output: on the Orion-Tr Smart isolated, Victron specifies 200 VDC galvanic isolation.
Does a DC-DC charger need a D+ signal?
Not a Victron Orion: it detects the running engine from its input voltage. Euro 6 vehicles often no longer provide D+. Where voltage detection isn’t enough, a real engine-running signal from the vehicle on the remote L-pin is the accurate option.