Victron MPPT error codes: what each Err means and how to clear it
A Victron MPPT error code is the number your SmartSolar or BlueSolar charge controller shows when it stops or limits charging to protect itself or the battery. Many clear by themselves once the cause is gone, like Err 2 (battery voltage too high) and Err 17 (controller overheated). Err 38 does not: disconnect the panels and the battery, wait 3 minutes, reconnect the battery first and then the panels. Err 67 means the charger expects a BMS and no longer hears it.
Below: where you see the code, a table of the codes a camper or boat system actually meets, the steps for the most searched ones, and how to keep an eye on your charger from the iPhone. Every meaning and fix here comes from Victron’s own page, MPPT Solar Charger Error Codes; if anything differs, Victron’s page wins.
Where you see a Victron MPPT error code
- VictronConnect: connect to the charger over Bluetooth (BlueSolar models through the VE.Direct Bluetooth Smart dongle). Past errors are also kept in the charger’s history data.
- A remote panel or GX device: Victron names the Color Control GX and the MPPT Control; a charger wired to a GX shows its error there and in VRM.
- The LEDs on the charger: they signal an error by blinking, without the number. Victron’s Toolkit app decodes the LED patterns.
The same list of codes applies to all Victron MPPT solar chargers, the Skylla chargers, the Inverter RS and Multi RS and the Orion Smart DC-DC chargers, so not every code can appear on every product.
Victron MPPT error codes: the table
The codes a SmartSolar or BlueSolar meets on a camper, van or boat, summarised from Victron’s page. “Clears by itself” means Victron says the error auto-resets once the cause is gone.
| Code | Meaning | What to do |
|---|---|---|
| Err 1 | Battery temperature too high | Clears by itself once the battery cools down. Charging stops meanwhile. The temperature comes from an external sensor (Smart Battery Sense, BMV) or from the charger itself. |
| Err 2 | Battery voltage too high | Clears by itself once the voltage drops. Check other chargers on the battery and the battery voltage setting (12/24/48 V). |
| Err 3, 4 | Remote temperature sensor failure | Check the T-sense connector; most likely it is on the BAT+ or BAT− terminal. Clears by itself once connected properly. |
| Err 5 | Remote temperature sensor connection lost | Check the T-sense connection. Does not clear by itself. |
| Err 6, 7 | Remote battery voltage sense failure | Check the V-sense connector; most likely it is connected in reverse polarity on BAT+ or BAT−. |
| Err 8 | Remote voltage sense connection lost | Check that the V-sense connector is properly connected to the battery terminals. |
| Err 14 | Battery temperature too low | Charging stops so LiFePO4 cells are not charged in the cold, which damages them. |
| Err 17 | Controller overheated despite reduced output current | Clears by itself once it cools down. Check the ambient temperature and anything blocking the heatsink. |
| Err 18 | Controller over-current | Clears by itself. If not: disconnect the charger from all power sources, wait 3 minutes, power up again. |
| Err 20 | Maximum bulk time exceeded | A protection removed from solar chargers after 2015: update the firmware; if it stays, reset to factory defaults and set the charger up again. |
| Err 21 | Current sensor issue | Disconnect and reconnect all wires; make sure nothing on the minus side bypasses the charger. Does not clear by itself; if it stays, contact your dealer. |
| Err 22, 23 | Internal temperature sensor failure | Disconnect and reconnect all wires. Does not clear by itself; if it stays, contact your dealer. |
| Err 26 | Terminal overheated | Check the wiring, cable type and strands, and tighten the bolts. Clears by itself. |
| Err 27 | Charger short circuit | Over-current on the battery side. Clears by itself; if not, disconnect all power sources, wait 3 minutes, power up. |
| Err 28 | Power stage issue | Disconnect and reconnect all wires. Does not clear by itself; if it persists, the charger is probably faulty. |
| Err 29 | Over-charge protection | Clears by itself below the float voltage. Check the absorption and float settings, too many panels in series, or another charger raising the voltage. |
| Err 33 | PV over-voltage | Clears by itself once the panel voltage drops. The open-circuit voltage of the array is critical for this charger: check how the panels are wired. |
| Err 34 | PV over-current | Disconnect all power sources, wait 3 minutes, power up. If it persists, the charger is probably faulty: contact your dealer. |
| Err 38 | PV input shutdown | Does not clear by itself: see the recovery steps below. |
| Err 39 | PV input shutdown | Resumes by itself once the battery voltage falls below the charger’s maximum setting; it can take a minute. |
| Err 40 | PV input failed to shut down | The charger goes into a safe mode, stops charging and disconnects its output; Victron says it becomes faulty. |
| Err 80 to 87 | PV input shutdown | 84–87: same steps as Err 38. 80–83: disconnect panels and battery, then follow Victron’s PV short relay reset. |
| Info 65 | Communication warning | Contact with a paralleled charger was lost: switch the charger off and on again. |
| Info 66 | Incompatible device | Paralleled chargers with different settings: align settings and firmware. Also shows with VE.Smart networking on MPPTs wired to a GX. |
| Err 67 | BMS connection lost | Check the connection between the charger and the BMS: see the section below. |
| Err 68 | Network misconfigured | Update the firmware; on VE.Can models, don’t connect both VE.Direct and VE.Can at the same time. |
| Err 114 | CPU temperature too high | Clears once it cools down. If it persists, check the ambient temperature and the air inlets and outlets. |
| Err 116 | Calibration data lost | Only in the history and the charger works: safe to ignore. Active and the charger doesn’t work: faulty, contact your dealer. |
| Err 117 | Incompatible firmware | A firmware update did not complete: run the update again. |
| Err 119 | Settings data lost | Does not clear by itself: factory reset, power cycle, set it up again (steps below). |
| Err 121 | Tester fail | Same as Err 116: harmless in the history, faulty if active and the charger doesn’t work. |
Victron’s list also has codes for other products: Err 11 and 50 to 59 for inverters, 69 to 77 for Inverter RS and Multi RS networks, Err 24 for Skylla chargers, Err 35, 41 to 43 and 200 to 215 mainly for the RS family. If you see one of those, read Victron’s page.
Victron MPPT Err 38: PV input shutdown
With Err 38 the charger shorts its PV input internally to protect the battery from over-charging. Victron gives two likely reasons:
- The battery voltage (12/24/36/48 V) is set wrong in the charger. Set the right one in VictronConnect.
- Another device on the battery is set to a higher voltage, for example a MultiPlus set to equalise at 17 V while the MPPT is not.
Before any other troubleshooting, Victron says to update the charger to the latest firmware. Err 38 does not reset on its own; this is Victron’s recovery:
- 1
Disconnect the solar panels.
- 2
Disconnect the battery.
- 3
Wait 3 minutes.
- 4
Reconnect the battery first.
- 5
Then reconnect the solar panels.
If the error comes back, the charge controller is probably faulty. Err 39 is the self-healing sibling: the charger resumes once the battery voltage falls below its maximum voltage setting (normally the equalisation or absorption voltage), which can take a minute.
Err 2: battery voltage too high
Err 2 clears by itself once the battery voltage drops. Victron lists three causes:
- Other charging equipment on the same battery is pushing the voltage up, for example a mains charger or a DC-DC charger.
- The battery voltage setting is lower than the battery, for example a charger set to 12 V on a 24 V battery.
- A fault in the charge controller.
If it keeps coming back, check the charge voltages of every charger on the battery so they agree. For a lithium battery: Victron MPPT settings for LiFePO4.
Err 67: BMS connection lost
Err 67 shows when the charger is set to be controlled by a BMS but receives no BMS messages. It then stops charging by lowering its output to the battery’s base voltage (12, 24, 36 or 48 V). A solar charger shows it only when there is solar power, so a permanent problem appears every morning and clears every night.
The fix is to check the connection between the charger and the BMS. If you moved the charger out of a system with a BMS or a GX, there is a catch: Victron chargers set themselves to BMS-controlled when they meet one, directly or through a GX device, and a power cycle does not undo it. To make it a standalone charger again:
- Chargers with an LCD display: in the setup menu, change setting 31 “BMS” from Y to N.
- Other chargers: reset the charger to factory defaults in VictronConnect, then set it up again.
Heat and current: Err 17, 18, 26, 34 and 114
- Err 17 and Err 114 are temperature: the controller or its CPU got too hot. Both clear once it cools down. Check the ambient temperature and anything blocking the heatsink or the air holes, and the cooling instructions in the manual.
- Err 18 is over-current on the battery side, from switching a very large load on or off, a sudden change in sunlight or an overloaded inverter. It clears by itself; better cooling, a smaller inverter load and a charged battery help.
- Err 26 is a hot power terminal: check the cable type and strands, and tighten the bolts.
- Err 34 is PV over-current, and can come from an internal fault: disconnect the charger from all power sources, wait 3 minutes and power up again. If it persists, contact your dealer.
Err 33: PV over-voltage
The panels deliver more voltage than the charger accepts. It clears by itself once the PV voltage falls to a safe level, but Victron reads it as a sign that the array’s open-circuit voltage is critical for this charger. The first number in the model name is the maximum PV voltage (100 V on a 100/30): check how many panels are in series and, if needed, rewire them, more in parallel and fewer in series.
Err 116, 119 and 121: data and firmware
- Err 116 (calibration data lost) and Err 121 (tester fail): if they appear only in the history and the charger works normally, ignore them; early units left the factory with them logged. If one is the active error and the charger doesn’t work, it is faulty: ask your dealer for a replacement. On SmartSolar models, going back from v1.4x firmware to an older one also gives Err 116; reinstalling v1.4x fixes it.
- Err 117: a firmware update did not complete, because the device went out of Bluetooth range, a cable came loose or the power dropped. Run the update again.
Err 119 means the charger can’t read its settings and has stopped. It does not reset on its own; Victron’s steps:
- 1
Restore factory defaults in VictronConnect (three dots, top right).
- 2
Disconnect the charge controller from all power sources.
- 3
Wait 3 minutes and power it up again.
- 4
Set the charger up again.
Victron asks you to report Err 119 to your dealer, with the firmware version, since it should never happen.
Your MPPT’s state and error code on the iPhone with Deeck
Deeck is an iPhone app, with widgets, Apple Watch and CarPlay, that reads your Victron devices nearby over Bluetooth, no GX needed. On the SmartSolar’s card a State box tells you what the charger is doing (Off, Bulk, Absorption, Float and the other states), and the moment the charger reports a fault an Error box appears with its number, for example “Code 17”. Find that number in the table above and you know what to do next. Orion XS DC-DC chargers and Blue Smart IP22 chargers show their state and error code the same way. All of this is free.
The same dashboard puts the MPPT’s live values, PV power, battery voltage and current and charge state, next to your SmartShunt, and push alerts watch the battery: low battery, low or high voltage, high temperature. With Deeck Plus the dashboard comes to CarPlay and, through Deeck Bridge, wherever you are. More on the charger in the app: Victron MPPT app; if the MPPT sits far from where you are, see Victron Bluetooth range.
SmartSolar, BlueSolar, VictronConnect and the other product names are Victron Energy products; Deeck is independent and not affiliated with Victron. Meanings and fixes summarise Victron’s MPPT error code page (revision of 30 September 2026); the page and your charger’s manual take precedence.
Questions people ask
What does error 38 mean on a Victron MPPT?
PV input shutdown: the charger shorts its panel input to protect the battery from over-charging, usually because the battery voltage is set wrong or another device charges at a higher voltage. Update the firmware, then disconnect panels and battery, wait 3 minutes, reconnect the battery first and then the panels.
What does Err 2 mean on a Victron solar charger?
Battery voltage too high. It clears by itself once the voltage drops. Common causes are another charger on the same battery or a battery voltage setting lower than the battery; it can also be a fault in the controller.
What is error 67 on a Victron MPPT?
BMS connection lost: the charger is set to follow a BMS and no longer receives its messages. Check the BMS connection; if the charger no longer has a BMS, reset it to factory defaults in VictronConnect (or set “BMS” to N on chargers with a display).
How do I reset a Victron MPPT error?
Many codes, like 1, 2, 17, 18, 26, 33 and 114, clear by themselves once the cause is gone. For others Victron’s usual step is to disconnect the charger from all power sources, wait 3 minutes and power up again; Err 38 needs the battery reconnected before the panels.