Victron MPPT calculator: which SmartSolar charge controller fits your solar panels

Two checks pick the SmartSolar. The second number in the name (the amps) must cover your panel watts at your battery voltage, and the first number (the volts) must stay above the open-circuit voltage of the panels in series on the coldest morning. At 12 V, Victron’s datasheets give up to 145 W for a 75/10, 220 W for a 75/15 or 100/15, 290 W for a 100/20, 440 W for a 100/30, 700 W for a 100/50 and 1000 W for a 150/70. At 24 V each figure doubles.

Below: how to read the name, the two checks step by step, the chart of the common SmartSolar models at 12, 24 and 48 V, worked examples from 100 W to 800 W, what happens if you connect more panels than the rating, and Victron’s own MPPT calculator.

How to read the name: 100/30, 150/35, 250/70

Every SmartSolar MPPT carries two numbers. The first is the maximum PV voltage: the open-circuit voltage of your panels must never go above it. The second is the maximum charge current into the battery, in amps.

  • SmartSolar MPPT 100/30: up to 100 V from the panels, up to 30 A into the battery.
  • SmartSolar MPPT 150/35: up to 150 V from the panels, up to 35 A into the battery.
  • SmartSolar MPPT 250/70: up to 250 V from the panels, up to 70 A into the battery.

The name doesn’t tell you the watts, because the same 30 A carries twice the power into a 24 V battery as into a 12 V one. That’s what the “nominal PV power” lines in Victron’s datasheets are for, and what the chart below collects.

Check 1: current, from your panel watts

  1. 1

    Add up the panel watts. Four 100 W panels are 400 W, however you wire them.

  2. 2

    Quick estimate: watts ÷ battery voltage. 400 W ÷ 12 V ≈ 33 A. This is the most the panels could push into the battery in full sun, and it errs on the safe side.

  3. 3

    Compare with the nominal PV power. Victron rates each model in watts per battery voltage, worked out at charging voltage rather than 12 V: the 100/30 takes 440 W at 12 V, which is 30 A at about 14.7 V. If your watts are at or below the figure in the chart for your battery voltage, the model fits.

Going a little over is not a fault. Every SmartSolar datasheet says the same: “If more PV power is connected, the controller will limit input power.” The controller caps the charge current at its rating and you lose some harvest at midday peaks, while mornings, evenings and cloudy days, when the panels give less than their rating, are unaffected.

The one current limit you must respect is the short-circuit current (Isc). Each datasheet gives a maximum PV short-circuit current and warns that “a PV array with a higher short circuit current may damage the controller.” Panels in parallel add up their Isc: check the sum against the last column of the chart.

Check 2: voltage, corrected for the cold

A panel’s open-circuit voltage (Voc) rises as it gets colder, and the Voc on the label is measured at 25 °C. On a cold, clear morning the panels can deliver more voltage than the label says, and voltage above the controller’s maximum can damage it. So correct the Voc for the lowest temperature you expect:

  1. 1

    Find two numbers on the panel datasheet: Voc, and the temperature coefficient of Voc, in %/°C (a negative figure).

  2. 2

    Cold Voc = Voc × (1 + coefficient × (25 − lowest temperature) ÷ 100), using the coefficient without its minus sign.

  3. 3

    Example at −10 °C: a panel with Voc 22.5 V and −0.30 %/°C. 25 − (−10) = 35 °C, × 0.30 = 10.5%, so the cold Voc is 22.5 × 1.105 = 24.9 V.

  4. 4

    Multiply by the panels in series. Two in series: 49.7 V, fine on a 75 V model. Three: 74.6 V, too close to 75 V, so take a 100 V model. Four: 99.5 V, too close to 100 V, so take a 150 V model or wire them two by two.

  5. 5

    Keep a margin below the maximum. On the 150 V models Victron gives 150 V as the absolute maximum in the coldest conditions and 145 V as the start-up and operating maximum; on the 250 V models, 250 V and 245 V.

There is also a minimum. The datasheets say the PV voltage must exceed the battery voltage + 5 V for the controller to start, and afterwards the minimum is battery voltage + 1 V. For a 12 V battery any standard panel clears it. For a 24 V battery, charged at 28.8 V by default, the panels must go above about 34 V to start: panels sold as “12 V” panels go at least two in series.

SmartSolar MPPT chart: current and nominal PV power

All figures from the Victron SmartSolar datasheets. Nominal PV power is the panel power at which the controller reaches its rated current; “–” means the model doesn’t support that battery voltage. The 150 V and 250 V models also work at 36 V, selected with a software tool.

SmartSolar MPPTMax PV voltageCharge currentPV power at 12 VPV power at 24 VPV power at 48 VMax PV Isc
75/1075 V10 A145 W290 W–13 A
75/1575 V15 A220 W440 W–15 A
100/15100 V15 A220 W440 W–15 A
100/20-48V100 V20 A290 W580 W1160 W20 A
100/30100 V30 A440 W880 W–35 A
100/50100 V50 A700 W1400 W–60 A
150/35150 V35 A500 W1000 W2000 W40 A
150/45150 V45 A650 W1300 W2600 W50 A
150/60150 V60 A860 W1720 W3440 W50 A
150/70150 V70 A1000 W2000 W4000 W50 A
250/60250 V60 A860 W1720 W3440 W35 A
250/70250 V70 A1000 W2000 W4000 W35 A

On the MC4 versions of the 150/60, 150/70, 250/60 and 250/70 Victron also gives a maximum of 30 A per MC4 connector.

Datasheets change between hardware revisions. Before you buy, check the datasheet of the exact model on victronenergy.com.

From panels to controller: worked examples

Example panels: a 100 W panel with Voc 22.5 V and a 200 W panel with Voc 24.0 V, both −0.30 %/°C, corrected to −10 °C (24.9 V and 26.5 V per panel). Use the numbers on your own panels: the method stays the same.

PanelsWiringCurrent checkCold Voc at −10 °CSmartSolar
100 W at 12 V1 panel100 ÷ 12 ≈ 8 A · up to 145 W24.9 V75/10
200 W at 12 V1 × 200 W200 ÷ 12 ≈ 17 A · up to 220 W26.5 V75/15 or 100/15
400 W at 12 V4 × 100 W, 2 in series × 2 strings400 ÷ 12 ≈ 33 A · up to 440 W49.7 V100/30
400 W at 12 V2 × 200 W in series400 ÷ 12 ≈ 33 A · up to 440 W53.0 V100/30
600 W at 12 V3 × 200 W in series600 ÷ 12 = 50 A · up to 700 W79.6 V100/50
800 W at 12 V4 × 200 W in series800 ÷ 12 ≈ 67 A · up to 860 W106.1 V150/60
800 W at 24 V4 × 200 W, 2 in series × 2 strings800 ÷ 24 ≈ 33 A · up to 880 W53.0 V100/30

Two things stand out. First, the 75 V models take at most two of these panels in series: three 100 W panels in series reach the limit on a cold morning. Second, moving the 800 W array from 12 V to 24 V lets a 100/30 do the job of a 150/60, because the same current carries twice the power.

With 800 W at 12 V you could also wire the four panels two by two (53.0 V) on a 100/50: the voltage is fine, but 800 W is above its 700 W rating, so the controller limits the input at peak sun. That’s allowed; the 150/60 simply harvests the full power.

Victron’s own MPPT calculator

Victron has an official sizing tool at mppt.victronenergy.com. You choose your panel from its database, enter how many panels go in series and in parallel, the battery voltage and the temperatures, and it works out the cold and hot PV voltage and the charge current and suggests matching controllers. Use it to confirm your choice once you know which panels you’ll buy; the two checks above tell you in a minute whether you’re in the right range.

Solar panel size: watts first, then the controller

If you don’t know yet how many watts of panels you need, start from your daily consumption: daily Wh ÷ peak sun hours at your location and season = panel watts, then round up for heat, dirt and cable losses. For example, 600 Wh a day with 3 peak sun hours gives 200 W before losses. The battery runtime calculator helps you add up your loads and see how solar changes the runtime. Then pick the controller with the two checks above.

After the install: your SmartSolar on iPhone

Once the controller is in, the Deeck app reads your SmartSolar MPPT over Bluetooth on iPhone, free. The controller’s card shows the solar power, today’s yield, the charge state (Off, Bulk, Absorption, Float), the battery voltage and current, the load current and, when there is one, the error code, which you can look up in our Victron MPPT error codes guide.

The 24-hour and 7-day charts are free too. They fill while your iPhone is in range of the MPPT; for a continuous history you need Deeck Bridge or VRM. Victron devices nearby over Bluetooth are free in Deeck. More: Victron MPPT app for iPhone.

Questions people ask

Can I connect more panels than the MPPT rating?

More watts, yes: Victron’s datasheets say that if more PV power is connected, the controller will limit input power. More voltage, no: the open-circuit voltage at your coldest temperature must stay below the first number in the name. And the short-circuit current of the array must stay below the controller’s maximum PV Isc, or it may damage the controller.

100/30 or 100/50 for 400 W of solar?

At 12 V a 100/30 is enough: Victron rates it for 440 W at 12 V. Take the 100/50 (700 W at 12 V) if you plan to add panels later. At 24 V, 400 W fits even a 100/15, rated for 440 W at 24 V.

Do I need a 150 V MPPT?

Only if the cold open-circuit voltage of your panels in series gets close to 100 V. Four panels with Voc 24 V reach about 106 V at −10 °C, so they need a 150 V model or have to be wired two by two. On the 150 V models Victron gives 145 V as the start-up and operating maximum.

12 V or 24 V system for solar?

At 24 V the same controller handles twice the panel power: a 100/30 takes 440 W at 12 V and 880 W at 24 V. For a larger array that often means a smaller controller and thinner cables. A 24 V battery needs the panels to exceed about 34 V to start charging, so 12 V-class panels go at least two in series.

What do the numbers in MPPT 100/30 mean?

100 is the maximum PV voltage in volts, 30 the maximum charge current into the battery in amps. The watts depend on the battery voltage: 440 W at 12 V and 880 W at 24 V for the 100/30, according to Victron’s datasheet.

Is there an official Victron MPPT calculator?

Yes, at mppt.victronenergy.com. You choose your panels from its database, enter series and parallel wiring, battery voltage and temperatures, and it checks voltage and current against Victron’s controllers.

On the dash and on your wrist

Sized right. Now watch it charge.

Seeing it is free. Having it on the dash and on your wrist is Deeck Plus.

Put it on CarPlay and Watch Download the app free

Free app · Deeck Plus €39.99 a year · cancel anytime · 14 days to change your mind