Victron SmartSolar MPPT 75/15, 100/20, 100/30 and 100/50: specs, which to choose and how to wire it
The two numbers in a Victron MPPT name are its limits: the first is the maximum open-circuit voltage of the panels, the second the maximum charge current into the battery. A 75/15 takes up to 75 V from the panels and charges at up to 15 A; a 100/30 takes up to 100 V and charges at up to 30 A. At 12 V that means up to 220 W of panels on a 75/15, 290 W on a 100/20, 440 W on a 100/30 and 700 W on a 100/50, according to Victron’s datasheets.
Below: the specs side by side, which one fits a camper or a boat, panel strings worked out with the cold-weather voltage, SmartSolar against BlueSolar, the connection order from the manual, the load output, and what Deeck shows. Figures come from Victron’s datasheets for the 75/10 to 100/20 and the 100/30 and 100/50, and from the two manuals (75/10 to 100/20, 100/30 and 100/50).
What 75/15 or 100/30 means
- First number, volts: the highest open-circuit voltage (Voc) the panels may ever reach. 75 V on the 75/15, 100 V on the 100/20, 100/30 and 100/50. Above it the controller stops charging with error #33, and Victron writes that damage from overvoltage is not covered by warranty.
- Second number, amps: the most current the controller pushes into the battery: 15, 20, 30 or 50 A. Connect more panel power and the controller simply limits its input; Victron allows that.
- Battery voltage: all four recognise 12 or 24 V by themselves. The 100/20 also charges 48 V batteries.
An MPPT charges a lower-voltage battery from higher-voltage panels: two panels in series feeding a 12 V battery is normal. There is a floor too. The panel voltage must be at least 5 V above the battery voltage for the controller to start, and at least 1 V above it afterwards.
Specs side by side
| Model | Charge current | Nominal PV power 12 / 24 / 48 V | Max PV voltage · max PV short-circuit current |
|---|---|---|---|
| 75/15 | 15 A | 220 W / 440 W / – | 75 V · 15 A |
| 100/20 | 20 A | 290 W / 580 W / 1160 W | 100 V · 20 A |
| 100/30 | 30 A | 440 W / 880 W / – | 100 V · 35 A |
| 100/50 | 50 A | 700 W / 1400 W / – | 100 V · 60 A |
| Model | Self-consumption | Terminals · battery fuse | Weight · size (h × w × d) |
|---|---|---|---|
| 75/15 | 19 mA at 12 V, 16 mA at 24 V with the load output on; 10 and 8 mA with it off | 6 mm² (AWG10) · 20–25 A | 0.5 kg · 100 × 113 × 40 mm |
| 100/20 | 26 / 20 / 19 mA at 12 / 24 / 48 V, load on; 10 / 8 / 7 mA, load off | 6 mm² (AWG10) · 25–30 A | 0.65 kg · 100 × 131 × 60 mm |
| 100/30 | 30 mA at 12 V, 20 mA at 24 V | 16 mm² (AWG6) · 35–40 A | 1.3 kg · 130 × 186 × 70 mm |
| 100/50 | 30 mA at 12 V, 20 mA at 24 V | 16 mm² (AWG6) · 55–70 A | 1.3 kg · 130 × 186 × 70 mm |
Common to all four: peak efficiency 98%, no fan, full rated output up to 40 °C and operation from −30 to +60 °C, IP43 for the electronics and IP22 for the connection area, a VE.Direct port and Bluetooth built in. Each stores 46 days of history. The battery fuse range is the manual’s minimum and maximum rating; the fuse is required even if the controller already has one.
Which one for your camper or boat
- Victron MPPT 75/15: one panel, small van or day boat. Up to 220 W at 12 V. Two 36-cell panels in series also fit under 75 V. Its load output can run small DC loads up to 15 A.
- SmartSolar 100/20: 250 to 290 W at 12 V, or a 48 V bank. The 100 V input takes three 36-cell panels in series. It is the only one of the four for 48 V, up to 1160 W.
- Victron MPPT 100/30: the common camper size. Two panels of about 200 W each at 12 V (up to 440 W), or up to 880 W on a 24 V boat.
- Victron 100/50: a full roof or deck. Up to 700 W at 12 V, 1400 W at 24 V. Same case as the 100/30, 1.3 kg.
Two practical points for a boat: Victron rates these controllers for indoor use, so they belong in a dry locker, and all models track the best power point when part of the array is shaded. On a camper the manual asks for a spot within 3 m of the battery, never directly above it, mounted vertically with the terminals down and 10 cm free above and below. For a full sizing walk-through with other models, see the Victron MPPT calculator.
Panels in series or parallel: worked examples
The voltage limit is checked at the coldest temperature you expect, because a panel’s Voc rises in the cold. The examples use Victron’s own BlueSolar mono panels from the panel datasheet: 130 W (Voc 24.8 V, Isc 6.53 A), 190 W (Voc 25.5 V, Isc 9.17 A) and 365 W (Voc 48.4 V, Isc 9.30 A), all with a Voc coefficient of −0.35%/°C.
- 1
Correct Voc for the cold. At −10 °C the panel is 35 °C below the 25 °C of the label: 35 × 0.35% = 12.25%. So 24.8 V becomes 27.8 V, 25.5 V becomes 28.6 V, 48.4 V becomes 54.3 V.
- 2
Series adds voltage, parallel adds current. Multiply the cold Voc by the panels in series; add the Isc of the strings in parallel.
- 3
Keep a margin. Victron’s rule of thumb is 10% below the maximum: about 67 V on a 75 V model, 90 V on a 100 V model. The short-circuit current must stay under the controller’s maximum PV current.
| Panels and battery | Wiring | Cold Voc at −10 °C · Isc | Controller |
|---|---|---|---|
| 1 × 190 W, 12 V | single panel | 28.6 V · 9.2 A | 75/15 (up to 220 W) |
| 2 × 130 W, 12 V | 2 in series | 55.7 V · 6.5 A | 100/20 (up to 290 W) |
| 3 × 130 W, 12 V | 3 in series | 83.5 V · 6.5 A | 100/30; over 75 V, so not a 75/15 |
| 2 × 190 W, 12 V | 2 in series | 57.2 V · 9.2 A | 100/30 (up to 440 W) |
| 3 × 190 W, 12 V | 3 in series | 85.9 V · 9.2 A | 100/50 (up to 700 W), inside the 90 V margin |
| 2 × 365 W, 24 V | 2 in parallel | 54.3 V · 18.6 A | 100/30 (up to 880 W) |
| 2 × 365 W, any | 2 in series | 108.7 V | Too high for all four: wire them in parallel |
| 4 × 190 W, 24 V | 2 in series × 2 strings | 57.2 V · 18.3 A | 100/30 (up to 880 W) |
Series or parallel? For a 12 V battery the manual recommends 72 cells in series for the best controller efficiency: two 36-cell panels in series or one 72-cell panel. Two 365 W panels on a 12 V battery in parallel would go on a 100/50; at 730 W they are slightly above its 700 W, so it trims the peak. On a 24 V battery the panels must go above about 34 V to start charging at the default 28.8 V: 36-cell panels go at least two in series. Colder where you travel? Redo step 1 with your own lowest temperature.
SmartSolar or BlueSolar
Victron makes each of these sizes twice. Charge currents, voltages and cases are the same; the difference is the radio.
- SmartSolar: Bluetooth built in, so VictronConnect connects directly for setup, firmware updates and history. It can join a VE.Smart network: a Smart Battery Sense or a BMV-712 Smart sends it the real battery voltage and temperature. Bluetooth can be switched off.
- BlueSolar: no Bluetooth. You set it up over VE.Direct, with the VE.Direct to USB interface or a VE.Direct Bluetooth Smart dongle. External sensing over Bluetooth works on SmartSolar models only.
Deeck reads a BlueSolar with the VE.Direct Bluetooth Smart dongle like a SmartSolar, with the same values; in the app its name can show as a generic «Solar Charger». The status is Recognised: Deeck recognises it by its protocol; if anything looks off, tell me and I’ll fix it. A BlueSolar connected to a GX also shows through VRM with Deeck Plus.
Wiring it: battery first, then the panels
- 1
Mount it vertically on a non-flammable surface, terminals down, within 3 m of the battery and not above it.
- 2
Fuse the battery cable close to the battery, with a rating from the table above.
- 3
Connect the battery first and wait 10 seconds: the controller recognises 12, 24 or 48 V by itself.
- 4
Check the system voltage in VictronConnect.
- 5
On the 75/15 and 100/20: connect the DC loads to the load output, if you use it.
- 6
Connect the panels last, with a way to disconnect them.
- 7
Plug in VE.Direct if you use a cable to a GX.
- 8
Tighten the terminals to 0.75 Nm on the 75/15 and 100/20, 1.6 Nm on the 100/30 and 100/50.
Victron allows connecting the panels first only if the system voltage was set by hand beforehand; otherwise the wrong order can disable or damage the controller. There is no on/off switch: to shut it down, the manual reverses the order, panels off first, then the battery. Check polarity before every connection, and don’t use panels with optimizers. For the cable between controller and battery, the cable size calculator gives the section for your length and current.
LiFePO4 settings
Out of the box these controllers charge at 14.4 V absorption and 13.8 V float on 12 V, which suits many lead batteries. For lithium iron phosphate you pick the LiFePO4 preset or your own values in VictronConnect; the 100/30 and 100/50 also have a rotary switch with eight preset algorithms. The values and the choice between preset and custom are in Victron MPPT settings for LiFePO4.
The load output
- 75/15 and 100/20: physical load output. Up to 15 A on the 75/15, 20 A on the 100/20 at 12 and 24 V, only 1 A on the 100/20 at 48 V. It is short-circuit proof and cuts the loads when the battery runs low: at 11.1 V or 11.8 V on 12 V, or with the BatteryLife algorithm, which raises the cut-off day by day until the panels can fill the battery again.
- Inverters and big loads go straight to the battery. The load output can still switch them through their remote on/off terminal, or through a BatteryProtect.
- 100/30 and 100/50: virtual load output. No load terminals. A VE.Direct TX digital output cable, set in VictronConnect, drives a BatteryProtect or a relay, switched by battery voltage or by BatteryLife.
Your SmartSolar on your iPhone with Deeck
Deeck reads every SmartSolar directly on the iPhone over Bluetooth, free and without a GX. The model doesn’t matter: 75/15, 100/20, 100/30 and 100/50 work the same way. You see the solar power in watts, today’s yield in kWh, battery voltage and current, and the charge state: bulk, absorption, float. When the controller reports a fault, Deeck shows «Error · Code N», explained in Victron MPPT error codes. Charts over 30 minutes, 24 hours and 7 days are free; 90 days come with Deeck Plus.
The first time, Deeck asks for the Bluetooth PIN, the one on the label or 000000, and works out the Instant Readout key by itself. Lost the PIN? See Victron Bluetooth PIN reset. With a SmartShunt or BMV next to it, Deeck also sends battery alerts: low charge, battery full, low or high voltage, high temperature. Widgets show the solar at a glance; CarPlay, Apple Watch and remote access through Deeck Bridge are part of Deeck Plus, at €39.99 a year.
SmartSolar, BlueSolar, VictronConnect and VRM are Victron Energy products; Deeck is independent and not affiliated with Victron. Figures summarise Victron’s datasheets and manuals; for your unit, the manual has the final word.
Questions people ask
What does 100/30 mean on a Victron MPPT?
100 is the maximum open-circuit voltage of the panels, 100 V; 30 is the maximum charge current into the battery, 30 A. At 12 V that is up to 440 W of panels, at 24 V up to 880 W.
How many watts of solar can a Victron MPPT 75/15 take?
Victron rates it for 220 W at 12 V and 440 W at 24 V. More panel power is allowed: the controller limits its input. The panels’ cold open-circuit voltage must stay under 75 V.
100/30 or 100/50 for a camper?
Add up the panel watts. Up to 440 W at 12 V, the 100/30 is enough; up to 700 W, take the 100/50. Same case, same 100 V input. At 24 V the limits double: 880 W and 1400 W.
Can I put two 365 W panels in series on a 100/50?
No. With the Victron 365 W panel (Voc 48.4 V) two in series reach about 108.7 V at −10 °C, over the 100 V limit. Wire them in parallel: about 54.3 V and 18.6 A, fine for a 100/30 at 24 V or a 100/50 at 12 V.
Does the SmartSolar 100/30 have a load output?
Not a physical one. The 75/15 and 100/20 have load terminals; the 100/30 and 100/50 offer a virtual load output through a VE.Direct TX cable driving a BatteryProtect or a relay.
Battery or panels first?
Battery first. The manual says to connect the battery, wait 10 seconds for the controller to recognise the voltage, check it in VictronConnect, then connect the panels. Panels first only if the system voltage was set by hand.
Does Deeck show my SmartSolar 75/15 or 100/30?
Yes, any SmartSolar, directly on the iPhone over Bluetooth and free: solar power, today’s yield, battery voltage and current, charge state, and the error code if there is one.