Victron Lithium SuperPack NG: the new 24 V and 48 V models, specs and charging settings

Victron’s Lithium SuperPack NG range has two new 5.1 kWh batteries: the 25.6 V/200 Ah and the 51.2 V/100 Ah, announced as available on 2 November 2026. They join the 12.8 V/100 Ah, 12.8 V/200 Ah and 25.6 V/100 Ah, and because SuperPack NG batteries can’t be wired in series, they are what a 24 V or 48 V system needs.

Below: the five models side by side, the charge voltages and currents from Victron’s datasheet, how self-heating works below 0 °C, why parallel is fine and series is not, the EFS signal, the 2C peak current for inverter sizing, and how to see the whole bank on your iPhone.

The five SuperPack NG models

All figures from Victron’s datasheet; capacity and energy at 25 °C. The two new models are the last two rows.

Nominal voltageCapacityEnergyMax continuous dischargeWeight
12.8 V100 Ah1,280 Wh200 A10.7 kg
12.8 V200 Ah2,560 Wh400 A20.5 kg
25.6 V100 Ah2,560 Wh200 A20.5 kg
25.6 V (new)200 Ah5,120 Wh400 A41 kg
51.2 V (new)100 Ah5,120 Wh200 A41 kg

There are three case sizes: 273 × 173 × 173 mm for the 12.8 V/100 Ah (BCI Group 49 dimensions), 466 × 198 × 173 mm for the 12.8 V/200 Ah and 25.6 V/100 Ah, and 871 × 198 × 173 mm for the two new models; add 15 mm of height for the terminal screws. Each battery mounts upright or on its long side, on a flat horizontal support.

All five share the same build: a built-in BMS and battery monitor, Bluetooth with VictronConnect, an on/off push button, IP65, M8 threaded terminals and 93% round-trip efficiency. Cycle life at 25 °C, to 80% of nominal capacity: 2500 cycles at 80% depth of discharge, 3000 at 70% and 5000 at 50%. Victron states a 15-year design life and a 5-year standard warranty.

Part numbers of the new models: BAT524120740 (25.6 V/200 Ah) and BAT548110740 (51.2 V/100 Ah).

Charge voltages and currents

Set every charger to a LiFePO4 (LFP) profile with bulk, absorption and float, never a lead-acid profile, using the values below. Victron asks for one complete charge before first use, so the built-in battery monitor starts from a correct state of charge.

Nominal voltageRecommended charge voltageFloatCharge voltage rangeEnd of discharge
12.8 V14 V13.5 V13.5–14.2 V11.2 V
25.6 V28 V27 V27–28.4 V22.4 V
51.2 V56 V54 V54–56.8 V44.8 V
ModelRecommended discharge (continuous use)Recommended charge currentMax continuous chargeSelf-heating max power
12.8 V/100 Ah50 A30 A100 A65 W
12.8 V/200 Ah100 A60 A200 A130 W
25.6 V/100 Ah50 A30 A100 A130 W
25.6 V/200 Ah100 A60 A200 A260 W
51.2 V/100 Ah50 A30 A100 A260 W

If several chargers feed the bank (solar, alternator via DC-DC, shore power), their combined current must stay within these limits. The resting voltage gives a rough idea of the state of charge: the tables for 8 and 16 cells are in our 24V LiFePO4 voltage chart and 48V LiFePO4 voltage chart. The SuperPack’s own monitor resets to 100% when the charged voltage and the tail current (default 4%) hold for the charged detection time (default 3 minutes).

Cold weather: self-heating below 0 °C

SuperPack NG works from -30 °C to +60 °C ambient, but charging is only permitted with the battery between 0 °C and 60 °C. Below 0 °C, charging is suspended while the internal heater warms the cells, and it resumes by itself once a safe charging temperature is reached. The heater draws up to 65 W, 130 W or 260 W depending on the model (table above). In VictronConnect you choose how it gets its energy:

  • Smart Heat (default): the heater runs only when a charger is connected, powered by the charger, so it doesn’t use battery energy.
  • Anti-freeze: the heater keeps the cells warm enough to charge even with no charger connected, using the battery’s own energy. When the state of charge falls below the Low SoC threshold, the heater switches off and charging stays unavailable.

For winter storage, Victron’s advice: charge the battery, switch it off with the push button (self-discharge is then under 3% a month), disconnect all loads, and don’t store it below 5 °C without a charging source connected. At 25 °C it can be stored for up to 1 year if it starts above 50%. More on lithium in the cold: LiFePO4 winter storage.

Parallel yes, series no: why the 24 V and 48 V models matter

Victron’s datasheet lists series configuration as “No” and parallel as “unlimited energy expansion, with power expansion limited to the system’s maximum current”. You can’t make 24 V from two 12.8 V SuperPacks or 48 V from four: you start from a battery that already has your system voltage, 25.6 V for 24 V and 51.2 V for 48 V. That is why the two new models matter. A 24 V system can now use 200 Ah batteries, and a 48 V system has a SuperPack NG of its own.

Parallel banks follow Victron’s rules:

  • The total system current must never exceed 800 A, the most a single SuperPack NG can safely interrupt, and the main fuse must not be rated above 800 A.
  • That limit does not grow with the bank: four 25.6 V/200 Ah in parallel could deliver more than 800 A together, but the system must still stay under it. For more power, Victron says to build separate, independently protected battery packs.
  • Fuse each battery on the positive side, and fuse the main positive cable to the bank.
  • Connect the system cables diagonally, so every battery sees the same current path, and size the main cable as one string cable times the number of strings.

The EFS signal and Instant Readout

The External Feedback Signal (EFS) is a single wire output that gives battery voltage, up to 250 mA, when it is active and floats at 0 V otherwise. It has two jobs:

  • External Charging Signal (ECS): disabled by default, you turn it on in VictronConnect. It goes high when the state of charge reaches the Low SoC warning threshold and stays high while the state of charge is below it or a charging current flows. It switches off when the state of charge is above the threshold and no charging current has been seen for more than 30 seconds. Because it is a steady on/off signal, it can energise a relay, drive a warning light or buzzer, or switch the remote on/off input of a BatteryProtect, a solar charger or an Orion XS, for example to start a charger.
  • External Disconnection Signal (EDS): always on. If current flows while the battery has switched off charging or discharging, which only happens in rare faults such as a failed electronic switch, the output sends a square-wave signal. It is meant for external logic or a safety relay as redundant protection, not to drive lamps or buzzers directly.

Never connect inductive, capacitive or high-current loads straight to the EFS output: use a relay. Victron specifies a wire of at least 0.75 mm² and a 315 mA fast-acting fuse; the EFS connector comes with the battery. On a MultiPlus-II, ECS can feed the AUX input through a separate relay, so the inverter/charger gets a warning before the battery protects itself against deep discharge.

Instant Readout lets VictronConnect show the battery’s voltage, current, state of charge, remaining time, temperature and consumed Ah, plus warnings and alarms, right in the device list without connecting. It is disabled by default: VictronConnect asks you to enable it when you first install it, otherwise you switch it on in the app.

2C for about 10 minutes: sizing the inverter

The max continuous discharge in the first table, 200 A or 400 A, is 2C. Victron’s footnote: at 25 °C ambient and 100% SoC, 2C can be sustained for approximately 10 minutes; the actual duration depends on temperature and voltage protection limits, and above this, overcurrent protection is triggered within 5 seconds. For continuous use Victron recommends 50 A on the 100 Ah models and 100 A on the 200 Ah models.

In practice: size the steady inverter load on the recommended current and let 2C cover peaks and short heavy loads. On both new models that is roughly 2.6 kW of DC power continuous (100 A at 25.6 V, or 50 A at 51.2 V) and about 10 kW for the 2C window (400 A at 25.6 V, or 200 A at 51.2 V). The higher voltage halves the current for the same power, which also means thinner cables: inverter cable size and our cable size calculator.

The whole bank on your iPhone with Deeck

Each SuperPack NG counts its own state of charge, which you see in VictronConnect. For the whole bank, including every load and charger, a Victron SmartShunt or BMV is what Deeck reads: the Deeck app picks it up over Bluetooth, with no GX, and shows the state of charge, current and voltage of the whole battery bank on your iPhone. Deeck doesn’t read the SuperPack’s own Bluetooth; the shunt sees the bank as one. Victron devices nearby are free in Deeck. Setup: Victron SmartShunt app.

With a GX device in the system, Deeck can also show the bank through Deeck Bridge or VRM. SuperPack and VictronConnect are Victron Energy products; Deeck is independent and not affiliated with Victron.

Questions people ask

Can you connect Victron SuperPack NG batteries in series?

No. Victron’s datasheet lists series configuration as “No”. Parallel is unlimited for capacity, with the system current capped at 800 A. For a 24 V system use the 25.6 V models, for 48 V the 51.2 V/100 Ah.

What charge voltage for the 25.6 V SuperPack NG?

Victron recommends 28 V, with 27 V float and a charge voltage range of 27–28.4 V; end of discharge is 22.4 V. Recommended charge current is 30 A for the 25.6 V/100 Ah and 60 A for the 25.6 V/200 Ah, with a maximum of 100 A and 200 A.

Does the SuperPack NG have Bluetooth?

Yes: Bluetooth with the VictronConnect app for setup, monitoring and firmware updates. Instant Readout, which shows the data in the device list without connecting, is off by default. To see the whole bank in Deeck on iPhone, add a Victron SmartShunt or BMV, which Deeck reads over Bluetooth.

How much does the 25.6 V/200 Ah SuperPack NG weigh?

41 kg, the same as the 51.2 V/100 Ah. Both measure 871 × 198 × 173 mm, plus 15 mm of height for the terminal screws, and store 5,120 Wh.

Can the SuperPack NG be charged below freezing?

Yes, thanks to self-heating. Below 0 °C charging is suspended while the internal heater warms the cells, then resumes by itself. In the default Smart Heat mode the heater runs only when a charger is connected; Anti-freeze mode uses battery energy instead.

Which SuperPack NG models are new?

The 25.6 V/200 Ah and the 51.2 V/100 Ah, both 5,120 Wh, announced as available on 2 November 2026. They join the 12.8 V/100 Ah, 12.8 V/200 Ah and 25.6 V/100 Ah.

On the dash and on your wrist

Your SuperPack bank, on your iPhone.

Seeing it is free. Having it on the dash and on your wrist is Deeck Plus.

Put it on CarPlay and Watch Download the app free

Free app · Deeck Plus €39.99 a year · cancel anytime · 14 days to change your mind