LiFePO4 charge voltage: how to charge a 12 V, 24 V or 48 V lithium battery

Charge a 12 V LiFePO4 battery with an absorption voltage of 14.0–14.4 V, which is 3.50–3.60 V per cell, and never above 14.6 V (3.65 V per cell). End absorption after a set time or when the current has dropped, then hold a float of 13.4–13.6 V or switch float off. A 24 V battery takes twice these values, a 48 V battery four times. No charging below 0 °C (some makers say +5 °C), and no temperature compensation.

This guide is about the charge itself: the charging profile stage by stage, what battery makers specify, how long absorption should last, float or no float, the cold, and what to set on a solar charger, a mains charger, a DC-DC charger and an inverter/charger. The numbers come from the makers’ public documents: the Victron Lithium Battery Smart manual, the SmartSolar MPPT manual, Battle Born, LiTime, Renogy and the EVE LF280K cell datasheet, linked where they’re used. If you want to know how full your battery is from its resting voltage, that’s the LiFePO4 voltage chart.

How a LiFePO4 charge works: bulk, absorption, float

A LiFePO4 battery charges in two main steps, constant current and then constant voltage. Chargers name them with the stages they already use for lead-acid, which is why the same words show up in VictronConnect and on most charger displays:

  • Bulk: the charger pushes as much current as it can, or as you allow, and the battery voltage climbs. Most of the energy goes in here.
  • Absorption: once the battery reaches the absorption voltage, the charger holds that voltage and the current falls by itself. This is where the battery tops up and where the BMS balances the cells.
  • Float: after absorption the charger drops to a lower voltage and only covers your loads. For lithium this stage is optional.
  • Storage: some chargers, such as the Blue Smart IP22, add a lower storage stage after some time. For lithium, Victron says to set it to the float voltage.

Victron also says to set the bulk voltage to the same value as the absorption voltage (Lithium Battery Smart, operation). Compared with a lead-acid profile, a lithium charge has no equalisation and no temperature compensation, and float can be switched off entirely.

LiFePO4 charge voltages for 12, 24 and 48 V

A 12 V LiFePO4 battery has 4 cells in series (4S), a 24 V battery 8 (8S), a 48 V battery 16 (16S). Every charge voltage is the cell voltage times the number of cells, so one per-cell value gives you all three systems.

BatteryAbsorption (bulk)FloatMaximum charge voltageEnd of discharge
Per cell3.50–3.60 V3.35–3.40 V or off3.65 V2.50–2.80 V
12 V (4S)14.0–14.4 V13.4–13.6 V or off14.6 V10.0–11.2 V
24 V (8S)28.0–28.8 V26.8–27.2 V or off29.2 V20.0–22.4 V
48 V (16S)56.0–57.6 V53.6–54.4 V or off58.4 V40.0–44.8 V

The 3.65 V and 2.5 V limits come from the cell maker: the EVE LF280K datasheet charges each cell at a constant 3.65 V. The 2.8 V end of discharge is Victron’s, 11.2 V on its 12.8 V Lithium Battery Smart. Battery makers set their absorption voltage a little below the cell limit, most often at 14.2 or 14.4 V on a 12 V battery.

The cell voltage is what the BMS watches. A 12 V battery at 14.4 V can still have one cell running ahead of the others, and the BMS cuts the charge when that single cell reaches its limit: on the Renogy Pro 12 V 100 Ah that’s 3.7 V per cell. Balanced cells are why absorption matters, see below.

What battery makers specify

The makers agree on the shape of the charge and differ by a few tenths of a volt. Where they differ, follow the datasheet of your battery: its BMS is set for those numbers.

Battery (12 V)AbsorptionFloatEnd of absorptionCharging allowed
Victron Lithium Battery Smart14.0–14.4 V, 14.2 V recommended13.5 V2 hours+5 to +50 °C
Victron Lithium NG14.0–14.2 V13.5 V–+5 to +50 °C
Battle Born14.4 V (14.2–14.6 V accepted)Not needed; under 13.6 V is fine30 minutes per battery in its inverter/charger guideKeep the battery above 35 °F (about 2 °C)
LiTime 12 V 50 Ah14.4 V ± 0.2 VNo permanent float; if needed 13.4–13.6 VFull at about 0.02C (1 A)0 to 50 °C
Renogy Pro 12 V 100 Ah14.4 V ± 0.2 VFloat keeps balancing the cells without damageBelow 5 A of charge current0 to 55 °C, built-in heater

Your battery’s datasheet comes first. A charger set above the voltage its BMS accepts makes the BMS disconnect the charge, and a charger set too low never lets the cells balance. For the Victron devices one by one: Victron LiFePO4 settings.

LiFePO4 absorption: time or tail current

Absorption ends in one of two ways: after a fixed time, or when the charge current falls below a threshold, the tail current. Both are valid; the makers just pick different ones.

  • Fixed time: Victron’s LiFePO4 preset on the SmartSolar MPPT holds 14.2 V for a fixed 2 hours and sets the tail current to 0 A, so that the full absorption time is available for cell balancing (MPPT manual).
  • Tail current: the charge is complete when the current drops low enough. Renogy ends at 5 A on a 100 Ah battery, the EVE cell datasheet at 0.05C, LiTime calls a battery full at about 0.02C. On a 100 Ah battery that’s 2–5 A.
  • Short fixed time: Battle Born suggests 30 minutes per battery on a Victron inverter/charger.

Balancing is the reason not to cut absorption too short. Victron’s battery manual says cell balancing only takes place during absorption, that it’s complete when all cells are at 3.55 V, and it recommends at least 2 hours of absorption a month for lightly cycled systems and 4–8 hours a month for heavily cycled ones (troubleshooting chapter).

At Victron, “tail current” means two different settings on the chargers and on the SmartShunt, and they have to agree for the SmartShunt to reset to 100 %: Victron tail current explained.

LiFePO4 float voltage: float or no float?

A LiFePO4 battery doesn’t need float to stay full. Battle Born says float charging isn’t necessary, LiTime asks for no permanent float, and Victron’s Blue Smart IP22 has float disabled in its Li-ion mode, with a 13.5 V storage stage instead (IP22 manual).

Float is still useful when the charger keeps running your loads: solar during the day, shore power at a campsite, an inverter/charger in a boat. At 13.4–13.6 V the charger supplies the fridge and the lights and the battery stays near full instead of cycling. Victron uses 13.5 V float in its LiFePO4 preset and for its own batteries; Renogy notes that float keeps balancing the cells without damaging the battery.

  • Loads running from the charger (van on solar, boat on shore power): float at 13.4–13.6 V, or what your datasheet says.
  • Battery charged and left alone (vehicle parked, winter): float off, or the charger disconnected; storage charge and checks are in LiFePO4 winter storage.
  • Never a lead-acid float: 13.8 V, the MultiPlus factory float for gel batteries, is above every lithium value in the table.

After float, the charger restarts a full cycle when the voltage drops: on the SmartSolar MPPT with the LiFePO4 preset that’s 0.1 V below float for one minute.

Charging in the cold: 0 °C and temperature compensation

LiFePO4 cells may be discharged below freezing, but not charged. The limit depends on the battery: 0 °C for the EVE cell, LiTime and Renogy, +5 °C for Victron’s lithium batteries, “above 35 °F” for Battle Born. Below it, either the BMS blocks the charge or a built-in heater warms the battery first (Renogy starts its heater below 5 °C while charge current flows).

  • Temperature compensation off: lead-acid chargers raise the voltage in the cold. Victron’s battery manual says to disable it or set it to 0 mV/°C; LiTime says off or minimal. Victron’s lithium presets and modes switch it off on the MPPT, the IP22 and the MultiPlus.
  • Low-temperature cut-off on: Victron chargers can stop charging below a set temperature, 5 °C by default on the MPPT once you enable it. On the MPPT and the Orion XS it only works with a battery temperature shared over VE.Smart, for example from a SmartShunt or BMV-712, and it isn’t needed when the battery blocks cold charging itself.
  • A BMS that controls the charger is what Victron recommends for its own batteries: the chargers switch off at the minimum temperature.

What to do over winter, charge level by manufacturer and frost limits: LiFePO4 winter storage.

LiFePO4 charging profile by charger type

The voltages are the same for every charger. What changes is where you set them and what else each charger needs to know.

ChargerVictron exampleLiFePO4 settingWatch out forGuide
Solar charge controllerSmartSolar MPPTLiFePO4 preset: 14.2 V for 2 h, float 13.5 V; or user-defined from your datasheetTail current 0 A in the preset; low-temperature cut-off needs a temperature sourceMPPT LiFePO4 settings
Mains chargerBlue Smart IP22Li-ion mode: 14.2 V, float off, storage 13.5 VCharge current within your battery’s limitIP22 LiFePO4 settings
DC-DC charger (alternator)Orion XSLithium preset or user-defined from your datasheetEngine shutdown detection and input voltage lock-out, so the starter battery isn’t drainedOrion XS LiFePO4 settings
Inverter/chargerMultiPlusLithium battery mode on, voltages from your battery manualFactory setting is gel: 14.4 V absorption, 13.8 V float, repeated absorptionMultiPlus LiFePO4 settings
Battery monitor (not a charger)SmartShunt or BMVCharged voltage and tail current matched to the chargersResets to 100 % only if the chargers reach its charged voltageSmartShunt LiFePO4 settings

A DC-DC charger sits between the starter battery and the lithium house battery and gives the lithium its own charge profile while you drive. Sizing and wiring are in the DC-DC charger guide. On the MultiPlus, Victron’s manual warns that the standard charging voltage may not suit your batteries (MultiPlus-II manual), and the VE.Bus guide says to set the charging voltages as per the battery manual.

With several chargers on one battery, give them the same absorption and float voltages, so that none of them stops the charge early for the others. Every Victron device in one table: Victron LiFePO4 settings.

How to charge a LiFePO4 battery, step by step

  1. 1

    Read the datasheet of your battery: absorption and float voltage, maximum charge current and the charging temperature range. Those numbers beat any table, this one included.

  2. 2

    Choose the lithium profile: the LiFePO4 preset or lithium mode of your charger if its values match the datasheet, otherwise a user-defined profile. Set bulk and absorption to the same voltage.

  3. 3

    Decide how absorption ends: a fixed time (Victron uses 2 hours) or a tail current (2–5 A on a 100 Ah battery, as the makers above specify).

  4. 4

    Set float to 13.4–13.6 V if the charger runs your loads, or switch it off.

  5. 5

    Switch temperature compensation off and equalisation off; switch on the low-temperature cut-off if your charger has a temperature source.

  6. 6

    Limit the charge current to what the battery and the cables accept. Victron recommends 0.5C for its batteries, 50 A on 100 Ah; LiTime recommends 0.2C for its 50 Ah battery.

  7. 7

    Watch the first full charge: the charger should go from bulk to absorption at the voltage you set and then to float or off. Check that every charger and the battery monitor agree on what full means.

Common LiFePO4 charging mistakes

  • Leaving a lead-acid profile on: the MultiPlus leaves the factory set for gel batteries, with a 13.8 V float and an absorption repeated every week.
  • Absorption voltage above what the battery accepts: the BMS disconnects the charge before it’s finished.
  • Absorption too short, every time: cells only balance during absorption, so they never get the time to do it.
  • Temperature compensation still on: in a cold van it raises the charge voltage above the lithium values.
  • Charging below the minimum temperature without a BMS or charger that blocks it.
  • Judging the charge from the voltage alone: during charging the battery always reads close to the charger’s setpoint, whatever its state of charge. The LiFePO4 voltage chart explains why only resting voltage means anything.

Watch the charge on your iPhone

Deeck shows on your iPhone, free, the voltage and current of your battery and its state of charge from a SmartShunt or a BMV Smart. On the page of a SmartSolar MPPT, an Orion XS or a Blue Smart IP22 it shows the State (Off, Bulk, Absorption, Float…), voltage and current. That way you see whether the charger enters absorption and switches to float at the right voltage.

Deeck doesn’t change the charge settings: you set them in VictronConnect. With Deeck Plus you get push alerts for low and high battery voltage, so a charger set too high or a battery running down doesn’t go unnoticed.

Many lithium batteries with a Bluetooth BMS from other brands can be read with Deeck Plus, cell voltages included: at the end of absorption you see whether the cells are close together. Which batteries: lithium battery app for iPhone.

Questions people ask

What is the charge voltage of a 12V LiFePO4 battery?

Usually 14.0–14.4 V absorption, which is 3.50–3.60 V per cell, never above 14.6 V. Victron recommends 14.2 V for 2 hours for its batteries; Battle Born, LiTime and Renogy specify 14.4 V. Follow the datasheet of your battery.

What float voltage should I use for LiFePO4?

13.4–13.6 V on a 12 V battery (26.8–27.2 V on 24 V, 53.6–54.4 V on 48 V), or no float at all. Float is useful when the charger keeps running your loads; for a battery left alone, switch it off or disconnect the charger.

How long should LiFePO4 absorption last?

It depends on the maker: Victron holds absorption for 2 hours, Battle Born suggests 30 minutes per battery, others end it when the current falls to about 0.02–0.05C (2–5 A on 100 Ah). Cells only balance during absorption, so Victron recommends at least 2 hours of it a month on lightly used systems.

What is the maximum charge voltage for LiFePO4?

3.65 V per cell, the charge limit in cell datasheets: 14.6 V for a 12 V battery, 29.2 V for 24 V and 58.4 V for 48 V. Battery makers set their absorption voltage a little lower, and the BMS disconnects the charge if a cell goes higher.

Can I charge a LiFePO4 battery with a lead-acid charger?

Only if you can set it to lithium values: absorption from your datasheet, float at 13.4–13.6 V or off, no equalisation and no temperature compensation. A fixed lead-acid profile floats too high, at 13.8 V on the MultiPlus gel setting.

Can I charge LiFePO4 below freezing?

No. Most batteries allow charging from 0 °C, Victron’s from +5 °C. Below that the BMS should block the charge, or a built-in heater warms the battery first. Discharging below freezing is allowed within the limits in the datasheet.