Victron Orion-Tr Smart: isolated or non-isolated, models, engine detection and wiring

The Victron Orion-Tr Smart is a DC-DC charger with Bluetooth: it charges the house battery from the starter battery and the alternator with a three-stage curve (bulk, absorption, float), and it can also work as a fixed-voltage power supply. It comes in two families. The isolated one has 200 VDC galvanic isolation between input, output and case, runs from 220 to 400 W and has 12, 24 and 48 V versions; the non-isolated one runs from 360 to 400 W, at 12 and 24 V. With 12 V on both sides, as in most campers, the model to look at is the 12/12-30: 12 V in, 12 V out, 30 A continuous at 40 °C.

Below: isolated against non-isolated, every model side by side, how it detects a running engine (smart alternators included), the LiFePO4 settings, fuses, cables and the connection order, status messages and error codes, the comparison with the Orion XS, and what Deeck shows. Figures come from Victron’s datasheets (isolated, non-isolated) and manuals (isolated, non-isolated).

What the Orion-Tr Smart does

The Orion-Tr Smart sits between the starter battery and the house battery. While the engine runs, it takes whatever the alternator delivers and charges the house battery with its own curve: bulk at full current, absorption at constant voltage, then float. Victron notes this matters most with a Euro 5 or Euro 6 smart alternator, which often supplies too low a voltage even with the engine running, and with long cables, as in boats and motorhomes. With a lithium house battery, controlled charging also protects the alternator, which a low-impedance battery could otherwise overload.

  • Charger or power supply. In charger mode it follows the charge algorithm. In power supply mode it holds a fixed output voltage set in VictronConnect: 10–15 V on 12 V output models, 18–30 V on 24 V, 40–60 V on 48 V.
  • Separates the batteries. With the engine off, starter and house batteries are separated, and the built-in engine shutdown detection stops charging, with no extra sensor and no CAN-bus connection.
  • Bluetooth and Instant Readout. Setup, firmware updates and monitoring go through VictronConnect; Instant Readout shows key data, warnings and alarms in the device list without connecting. There is no VE.Direct port.
  • Parallel. All models are short-circuit proof, and Victron allows an unlimited number of units in parallel for more current.

The name reads input voltage / output voltage – continuous current: a 12/12-30 takes 12 V and delivers 30 A at 12 V, at nominal output voltage and 40 °C. A 12/24-15 charges a 24 V bank from a 12 V vehicle.

Orion-Tr Smart isolated vs non-isolated

Both families charge the same way, with the same Bluetooth, case and settings. The difference is the electrical separation between input and output.

IsolatedNon-isolated
Galvanic isolation200 VDC between input, output and caseNone
Power220–280 W and 360–400 W360–400 W
Battery voltages12, 24 and 48 V, in and out12 and 24 V, in and out
Models14: five at 220–280 W, nine at 360–400 W4: 12/12-30, 12/24-15, 24/12-30, 24/24-17
Remote on/off, option dIsolated remote on/off cable, for example from a small BMSBMS control through the H pin

Non-isolated: the usual camper choice. In most vans and motorhomes the starter and house batteries already share the chassis as negative, so input and output can share it too. A 12 V vehicle with a 12 V house battery: the non-isolated 12/12-30.

Isolated: when the two sides must stay apart. On the isolated unit, Victron writes, input and output are galvanically isolated and do not necessarily share the same negative. That suits a boat where the house circuit is kept separate from the engine circuit, systems at different voltages with separate negatives, and any 48 V side: only the isolated family has 48 V input or output versions, and the smaller 220–280 W models. One practical consequence: the remote on/off and an engine-running signal must come from the input (starter) side; a signal referenced to the house battery has no effect.

All Orion-Tr Smart models

ModelVersionsInput range · output adjust rangeCurrent · power at 40 °C
12/12-18Isolated8–17 V · 10–15 V18 A · 220 W
12/12-30Isolated and non-isolated8–17 V · 10–15 V30 A · 360 W
12/24-10Isolated8–17 V · 18–30 V10 A · 240 W
12/24-15Isolated and non-isolated8–17 V · 18–30 V15 A · 360 W
12/48-8Isolated8–17 V · 40–60 V8 A · 360 W
24/12-20Isolated16–35 V · 10–15 V20 A · 240 W
24/12-30Isolated and non-isolated16–35 V · 10–15 V30 A · 360 W
24/24-12Isolated16–35 V · 18–30 V12 A · 280 W
24/24-17Isolated and non-isolated16–35 V · 18–30 V17 A · 400 W
24/48-8.5Isolated16–35 V · 40–60 V8.5 A · 400 W
48/12-20Isolated32–70 V · 10–15 V20 A · 240 W
48/12-30Isolated32–70 V · 10–15 V30 A · 360 W
48/24-16Isolated32–70 V · 18–30 V16 A · 380 W
48/48-8Isolated32–70 V · 40–60 V8 A · 380 W

Common to all: output voltage tolerance ±0.2 V, efficiency 87–89%, standby current under 1 mA, operation from −20 to +55 °C with 3% less output per °C above 40 °C, IP43 for the electronics and IP22 for the connection area when mounted with the terminals down, screw terminals for cables up to 16 mm² (AWG6). The input shuts down below 7 V (14 V on 24 V input, 28 V on 48 V input) and restarts at 7.5, 15 and 30 V. Set at or below the nominal output voltage, the output stays stable across the whole input range; set higher, the minimum input voltage rises by the same percentage.

The 360–400 W models with a 12 V input or output weigh 1.8 kg and measure 131 × 187 × 86 mm; the others 1.6 kg and 131 × 187 × 71 mm. The 220–280 W isolated models weigh 1.3 kg. Victron’s datasheets add that VictronConnect does not display the current in or out.

Engine running detection and remote on/off

The Orion-Tr Smart decides from its input voltage whether the engine is running. Charging starts when the voltage rises above the start level; if it stays below the shutdown level for more than one minute, the charger concludes the engine is off and stops, so short dips don’t interrupt it. In VictronConnect you choose «Smart Alternator» (the default), «Regular Alternator», or your own values, which show as «User defined». Detection works in charger mode only; in power supply mode the input voltage lock-out decides when the output is on.

Setting (12 / 24 / 48 V input)Smart alternator (default)Regular alternator
Start voltage: charging starts at once14 / 28 / 56 V14 / 28 / 56 V
Delayed start voltage13.3 / 26.6 / 53.2 V13.8 / 27.6 / 55.2 V
Delay at the delayed start voltage120 s120 s
Shutdown voltage: engine off after 1 minute below it13.1 / 26.2 / 52.4 V13.5 / 27 / 54 V

The levels can be set between 8 and 17 V on 12 V input models, 16 and 35 V on 24 V, 32 and 68 V on 48 V. The input voltage lock-out is the last guard for the starter battery: below it, charging stops at once. Default in charger mode on 12 V input: lock-out 12.5 V, restart 12.8 V; in power supply mode 10.5 V and 12 V. The manual’s rule: lock-out no higher than the shutdown voltage minus the voltage drop in the input cable. For scale, a 12/12-30 draws about 35 A from its input at full output.

Euro 6 smart alternator

A smart alternator varies roughly between 12.5 and 15 V on a 12 V system and can switch off for a while during the drive. The starter battery then falls back to its resting voltage, about 12.6 V, and the Orion-Tr can conclude the engine has stopped even though you are driving. With enough loads on, the alternator holds at least about 13.8 V and detection works. Victron notes results differ from vehicle to vehicle, even within the same model. First step: lower the start and shutdown voltages a little, at the cost of a smaller margin. If that isn’t enough, use an engine-running signal.

Engine-running signal and remote on/off

  • Remote on/off: the Orion-Tr ships with a wire loop between the L and H pins, so it is always on. Remove it to use a switch between L and H, a switched plus on H (on above 3 V), a switched minus or chassis on L (on below 5 V), or a BMS (option d in the table above).
  • Engine-running signal: more than 7 V on the L pin forces charging on, even after engine shutdown has been detected. Leave detection enabled in VictronConnect: it is still what stops charging when the engine is off. The signal can’t share the L pin with a remote switched to minus.
  • Which source: the vehicle’s own engine-running signal is the most accurate. D+ is often missing on Euro 6 vehicles, and D+ simulators read the same alternator voltage the charger already measures. Victron does not recommend the ignition switch: with the ignition on and the engine off, the charger drains the starter battery.

Switching detection off («forced charging») makes the Orion-Tr draw from the starter battery even with the engine off; only the input voltage lock-out stops it then. Victron writes that in most 12 V systems 12.5 V is low enough.

LiFePO4 settings in VictronConnect

In Settings › Battery settings › Battery preset you pick one of the eight pre-programmed battery settings or define your own. Absorption voltage, float voltage, bulk time limit, re-bulk voltage offset, adaptive absorption and absorption time are all preset values you can change; custom presets are saved in VictronConnect’s library. For lithium the absorption time is fixed, 2 hours by default.

The Orion-Tr manual gives no lithium voltages: take them from your battery’s datasheet. Victron’s lithium values and how presets work across Victron chargers are in Victron LiFePO4 settings; voltage against state of charge in the LiFePO4 voltage chart; the matching battery monitor setup in SmartShunt LiFePO4 settings.

Set the charge algorithm before connecting the battery, as the manual asks. The manual lists no charge current setting for the Orion-Tr: choose the model by its rated current, within what your house battery accepts and your alternator can spare. If your BMS has an allowed-to-charge contact, it can switch the charger through the remote connector.

Wiring: fuses, cable and connection order

  1. 1

    Mount it vertically on a non-flammable surface, terminals down, with 10 cm free above and below, close to the battery but never directly above it.

  2. 2

    Remove the remote wire loop or unplug its terminal block.

  3. 3

    Connect the input from the starter battery, with a fuse at the battery. Cables to the Orion first, check polarity again, then the battery.

  4. 4

    Set it up in VictronConnect: charger mode and the charge algorithm for your house battery.

  5. 5

    Connect the house battery to the output, with its own fuse.

  6. 6

    Put the remote back to switch the charger on.

  7. 7

    Tighten the terminals to 1.6 Nm and hold the torque for 5 seconds.

Side (input or output)Battery fuseMinimum cable at 0.5 · 1 · 2 mMinimum cable at 5 · 10 m
12 V60 A6 · 10 · 10 mm²16 · 16 mm²
24 V30 A4 · 6 · 6 mm²10 · 10 mm²
48 V20 A2.5 · 4 · 4 mm²6 · 6 mm²

Each side takes the fuse and cable of its own voltage: a 12/24-15 has a 12 V input and a 24 V output. Use flexible multi-strand copper with strands no thicker than 0.4 mm; a 16 mm² cable should have at least 122 strands. Thicker strands give too small a contact area and can overheat the terminal. For your own length and current, the cable size calculator gives the cross-section.

The Orion-Tr Smart is not protected against reverse polarity: Victron doesn’t cover the damage under warranty and a damaged unit can’t be repaired. Check polarity before connecting each battery. On an isolated unit the input negative goes to the starter side and the output negative to the house battery.

Not charging: status messages and error codes

VictronConnect shows why charging is off at the top of the status screen.

MessageWhat to check
Remote input inactiveRemote terminal block plugged in, the wire loop or switch between L and H, the BMS allowed-to-charge contact
Disabled in settingsCharger enabled in the battery settings
Input voltage lock-outStarter battery low, or lock-out set too high for a smart alternator or for the cable drop
Engine shutdown detectedAlternator type and start and shutdown voltages; if the input voltage collapses as soon as charging starts, the alternator can’t supply the power
  • Error 2, battery voltage too high: resets once the voltage drops; often another charger on the same battery.
  • Error 26, terminal overheated: check cable type, strands and torque. Resets by itself.
  • Error 27, charger short circuit: over-current on the battery side, for example with a contactor. If it doesn’t reset, disconnect all power, wait 3 minutes and power up again.
  • Error 116, calibration data lost: a fault only if it is active and the unit doesn’t work; in the history alone it can be ignored.
  • Error 119, settings data lost: restore factory defaults, disconnect all power for 3 minutes, set it up again.

Blue LED off? Either there is no input voltage, Bluetooth is set to «Enabled for 30 seconds» (power it up again and connect within 30 seconds), or it was set to «Disabled», which Victron says is permanent. Only one phone or tablet can connect at a time.

Orion-Tr Smart vs Orion XS

Victron makes both. They do the same job in different ways; Orion XS figures come from the Orion XS datasheet.

Orion-Tr SmartOrion XS
Output220–400 W, 8 to 30 A depending on the model700 W (12/12-50A), 1000 W (12/12-70A), 1400 W (XS 1400)
Current settingThe model’s rated current1–50 A (1–70 A on the 70 A), input and output
Voltages12, 24 and 48 V, also 12 to 24 V or 24 to 12 V12/12 models 9–17 V in; XS 1400 9–35 V in, 10–35 V out
Galvanic isolationIsolated version, 200 VDCNot listed in the datasheet
Charge algorithm3 stagesAdaptive, 4 stages
Efficiency · weight87–89% · 1.3–1.8 kgUp to 98.5% · 0.33–0.52 kg
ProtectionIP43 electronics, IP22 connection areaIP65 (12/12-70A: IP20)
DataBluetooth, no VE.DirectBluetooth and VE.Direct with DVCC

In short: the Orion-Tr Smart covers isolation, 48 V and conversion between 12 and 24 V; the Orion XS gives higher, adjustable current in a smaller case and connects to a GX. Both detect the engine from the input voltage and both work with smart alternators. In Deeck, charging the starter battery from the house battery with a command from the iPhone exists for the Orion XS only. More in Victron Orion XS app, Orion XS LiFePO4 settings, Orion XS: charge the starter battery and the general DC-DC charger guide. Against a plain relay: Victron Cyrix.

Your Orion-Tr Smart on your iPhone with Deeck

Deeck reads the Orion-Tr Smart, isolated and non-isolated, directly on the iPhone over Bluetooth, free and without a GX. Its card shows the input voltage from the starter side, the output voltage to the house battery and the state; when there is one, the error code and the reason it switched off. Both voltages also go into the charts: 30 minutes, 24 hours and 7 days for free, 90 days with Deeck Plus. The Orion-Tr doesn’t broadcast its current, so Deeck shows the input and output voltages.

Status in Deeck: Recognised. Deeck recognises it by its protocol; if anything looks off, write to me and I’ll fix it. The first time, Deeck asks for the Bluetooth PIN, the one on the label or 000000, and works out the Instant Readout key by itself (Victron Bluetooth PIN reset). Settings stay in VictronConnect: Deeck reads the Orion-Tr, it doesn’t send it commands.

With a SmartShunt or BMV on the house battery, Deeck adds battery alerts: low charge, low or high voltage, high temperature. Deeck Plus, at €39.99 a year, adds CarPlay, Apple Watch, VRM and remote access through Deeck Bridge.

Orion-Tr Smart, Orion XS, Cyrix, SmartShunt, BMV, VictronConnect and VRM are Victron Energy products; Deeck is independent and not affiliated with Victron. Figures summarise Victron’s datasheets and manuals; for your unit, the manual has the final word.

Questions people ask

Isolated or non-isolated Orion-Tr Smart for a camper?

In most vans and motorhomes the starter and house batteries share the chassis negative, so the non-isolated version fits, typically the 12/12-30. Take the isolated one when input and output must keep separate negatives, as on many boats, or when one side is 48 V.

What does Orion-Tr Smart 12/12-30 mean?

12 V input, 12 V output, 30 A continuous at nominal output voltage and 40 °C, which is 360 W. For 10 seconds it can deliver 40 A.

Does the Orion-Tr Smart work with a Euro 6 smart alternator?

Yes. Its engine shutdown detection defaults to «Smart Alternator»: on a 12 V input, charging starts at 14 V, or at 13.3 V after 120 seconds, and stops after one minute below 13.1 V. If your alternator switches off for long stretches while driving, lower the levels a little or wire an engine-running signal to the L pin.

Why can’t I see the charge current of my Orion-Tr Smart?

It doesn’t report it: Victron’s datasheet states that VictronConnect does not display current in or out. You see input and output voltage and the charge state. For the current into the battery, use a battery monitor such as a SmartShunt.

What fuse and cable does a 12/12-30 need?

Victron recommends a 60 A fuse on each 12 V side and at least 6 mm² for 0.5 m, 10 mm² for 1 to 2 m, 16 mm² for 5 to 10 m. The terminals take up to 16 mm².

Can the Orion-Tr Smart work as a 12 V power supply?

Yes. In power supply mode it holds a fixed output voltage set over Bluetooth, 10–15 V on 12 V output models. Set at or below nominal, the output stays stable across the whole input range.

Does Deeck show the Orion-Tr Smart?

Yes, isolated and non-isolated, free on the iPhone over Bluetooth: input and output voltage, state, and the error code and off reason when there is one. The status is Recognised.

On the dash and on your wrist

Your Orion-Tr Smart, live on your iPhone.

Seeing it is free. Having it on the dash and on your wrist is Deeck Plus.

Put it on CarPlay and Watch Download the app free

Free app · Deeck Plus €39.99 a year · cancel anytime · 14 days to change your mind